Literature DB >> 30298624

Digital evaluation of marginal and internal fit of single-crown fixed dental prostheses.

Bjørn E Dahl1, Jon E Dahl2,3, Hans J Rønold1.   

Abstract

The present study used a new, digitized version of the impression replica technique, namely the dual-scan technique, to evaluate the adaptation of single-crown fixed dental prostheses (FDPs). Scans of the bare master model and of the master model with a silicone layer representing the cement layer were superimposed and analyzed using designated software. Single crowns produced using the lost-wax metal casting technique were included. The cement space of the band width, 0.5-1.0 mm from the preparation margin (marginal fit), was smallest for crowns made from laser-sintered cobalt-chromium. The internal fit in both mesial-distal and buccal-palatal directions was statistically significantly better for crowns made using the conventional lost-wax metal casting technique than for crowns produced using computer-aided design/computer-aided manufacturing (CAD/CAM). Fixed dental prostheses produced by milled cobalt-chromium had the loosest internal fit. The results agree with those of our previous study of the same test specimens, in which the triple-scan method was used, and imply that the dual-scan method is well suited for adaptation studies.
© 2018 Eur J Oral Sci.

Entities:  

Keywords:  CAD/CAM; cobalt chromium; dual scan; lithium disilicate glass-ceramic; zirconium dioxide

Mesh:

Substances:

Year:  2018        PMID: 30298624     DOI: 10.1111/eos.12576

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  6 in total

1.  The flexural strength of CAD/CAM polymer crowns and the effect of artificial ageing on the fracture resistance of CAD/CAM polymer and ceramic single crowns.

Authors:  Anna Winter; Axel Schurig; Engelke Rasche; Franziska Rösner; Lisa Kanus; Marc Schmitter
Journal:  J Mater Sci Mater Med       Date:  2019-12-23       Impact factor: 3.896

Review 2.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03

3.  Comparison of internal fit of metal-ceramic crowns in CAD/CAM and lost-wax techniques in all fabrication stages through replica weighting, triple scanning, and scanning electron microscope.

Authors:  Sina Mohammadi Sadr; Elham Ahmadi; Masoumeh Hasani Tabatabaei; Saba Mohammadi; Faezeh Atri
Journal:  Clin Exp Dent Res       Date:  2022-02-20

4.  The Impact of Sintering Technology and Milling Technology on Fitting Titanium Crowns to Abutment Teeth-In Vitro Studies.

Authors:  Wojciech Ryniewicz; Łukasz Bojko; Anna M Ryniewicz
Journal:  Materials (Basel)       Date:  2022-08-24       Impact factor: 3.748

5.  Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study.

Authors:  Afra Hassan Elrashid; Amjad Hamod AlKahtani; Shatha Jarallah Alqahtani; Nouf Bati Alajmi; Fatimah Hussain Alsultan
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-13

6.  Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques.

Authors:  Hasan Kocaağaoğlu; Haydar Albayrak; Sezgi Cinel Sahin; Ayşegül Güleryüz Gürbulak
Journal:  J Adv Prosthodont       Date:  2019-10-30       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.