Literature DB >> 35186360

Developing a control framework for self-adjusting prosthetic sockets incorporating tissue injury risk estimation and generalized predictive control.

F M Mbithi1, A J Chipperfield1, J W Steer1, A S Dickinson1.   

Abstract

To perform activities of daily living (ADL), people with lower limb amputation depend on the prosthetic socket for stability and proprioceptive feedback. Poorly fitting sockets can cause discomfort, pain, limb tissue injuries, limited device usage, and potential rejection. Semi-passively controlled adjustable socket technologies exist, but these depend upon the user's perception to determine safe interfacial pressure levels. This paper presents a framework for automatic control of an adjustable transtibial prosthetic socket that enables active adaptation of residuum-socket interfacial loading through localized actuators, based on soft tissue injury risk estimation. Using finite element analysis, local interfacial pressure vs. compressive tissue strain relationships were estimated for three discrete anatomical actuator locations, for tissue injury risk assessment within a control structure. Generalized Predictive Control of multiple actuators was implemented to maintain interfacial pressure within estimated safe and functional limits. Controller simulation predicted satisfactory dynamic performance in several scenarios. Actuation rates of 0.06-1.51 kPa/s with 0.67% maximum overshoot, and 0.75-1.58 kPa/s were estimated for continuous walking, and for a demonstrative loading sequence of ADL, respectively. The developed platform could be useful for extending recent efforts in adjustable lower limb prosthetic socket design, particularly for individuals with residuum sensory impairment. © Korean Society of Medical and Biological Engineering 2021.

Entities:  

Keywords:  Adjustable prosthetic socket; Finite element analysis; Generalized predictive control; Interface pressure control; Transtibial

Year:  2021        PMID: 35186360      PMCID: PMC8825909          DOI: 10.1007/s13534-021-00211-x

Source DB:  PubMed          Journal:  Biomed Eng Lett        ISSN: 2093-9868


  33 in total

1.  Comparison of the effects of patellar tendon bearing and total surface bearing sockets on prosthetic fitting and rehabilitation.

Authors:  K Yiğiter; G Sener; K Bayar
Journal:  Prosthet Orthot Int       Date:  2002-12       Impact factor: 1.895

2.  Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Niyousha Mortaza; Arezoo Eshraghi; Hossein Gholizadeh; Wan Abu Bakar Bin Wan Abas
Journal:  Clin Biomech (Bristol, Avon)       Date:  2012-07-12       Impact factor: 2.063

Review 3.  Sensing and actuation technologies for smart socket prostheses.

Authors:  Sumit Gupta; Kenneth J Loh; Andrew Pedtke
Journal:  Biomed Eng Lett       Date:  2019-11-12

Review 4.  Advanced technologies for intuitive control and sensation of prosthetics.

Authors:  Erik J Wolf; Theresa H Cruz; Alfred A Emondi; Nicholas B Langhals; Stephanie Naufel; Grace C Y Peng; Brian W Schulz; Michael Wolfson
Journal:  Biomed Eng Lett       Date:  2019-08-08

5.  Key considerations for finite element modelling of the residuum-prosthetic socket interface.

Authors:  Joshua W Steer; Peter R Worsley; Martin Browne; Alex Dickinson
Journal:  Prosthet Orthot Int       Date:  2021-04-01       Impact factor: 1.895

6.  A motor-driven adjustable prosthetic socket operated using a mobile phone app: A technical note.

Authors:  Joan E Sanders; Joseph L Garbini; Jake B McLean; Paul Hinrichs; Travis J Predmore; Jacob T Brzostowski; Christian B Redd; John C Cagle
Journal:  Med Eng Phys       Date:  2019-04-23       Impact factor: 2.242

7.  Prediction of the biomechanical effects of compression therapy by finite element modeling and ultrasound elastography.

Authors:  Fanny Frauziols; Jérôme Molimard; Laurent Navarro; Pierre Badel; Magalie Viallon; Rodolphe Testa; Stéphane Avril
Journal:  IEEE Trans Biomed Eng       Date:  2015-04       Impact factor: 4.538

8.  Patient-specific analyses of deep tissue loads post transtibial amputation in residual limbs of multiple prosthetic users.

Authors:  S Portnoy; I Siev-Ner; N Shabshin; A Kristal; Z Yizhar; A Gefen
Journal:  J Biomech       Date:  2009-09-18       Impact factor: 2.712

9.  Preliminary investigation of residual-limb fluid volume changes within one day.

Authors:  Joan E Sanders; Katheryn J Allyn; Daniel S Harrison; Timothy R Myers; Marcia A Ciol; Elaine C Tsai
Journal:  J Rehabil Res Dev       Date:  2012

10.  Development of an air pneumatic suspension system for transtibial prostheses.

Authors:  Gholamhossein Pirouzi; Noor Azuan Abu Osman; Azim Ataollahi Oshkour; Sadeeq Ali; Hossein Gholizadeh; Wan A B Wan Abas
Journal:  Sensors (Basel)       Date:  2014-09-09       Impact factor: 3.576

View more