Emily Lam1, Milad Alizadeh-Meghrazi1,2,3, Alessandra Schlums4, Ladan Eskandarian2,5, Amin Mahnam2, Bastien Moineau1,2,3, Milos R Popovic1,3. 1. Institute of Biomedical Engineering, University of Toronto, Toronto, Canada. 2. Myant Inc, Etobicoke, Canada. 3. The KITE Research Institute, Toronto Rehabilitation Institute - University Health Network, Toronto, Canada. 4. Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Canada. 5. Department of Materials Science and Engineering, University of Toronto, Toronto, Canada.
Abstract
INTRODUCTION: In recent years, electromyography (EMG) has been increasingly studied for wearable applications. Conventional gel electrodes for electrophysiological recordings have limited use in everyday applications such as prosthetic control or muscular therapy at home. This study investigates the efficacy and feasibility of dry-contact electrode materials employed in smart textiles for EMG recordings. METHODS: Dry-contact electrode materials were selected and implemented on textile substrates. Using these electrodes, EMG was recorded from the forearm of able-bodied subjects. 25% and 50% isometric maximum voluntary contractions were captured. A comparative investigation was performed against gel electrodes, assessing the effect of material properties on signal fidelity and strength compared. RESULTS: When isolating for electrode surface area and pressure, 31 of the 40 materials demonstrated strong positive correlations in their mean PSD with gel electrodes (r > 95, p < 0.001). The inclusion of ionic liquids in the material composition, and using raised or flat electrodes, did not demonstrate a significant effect in signal quality. CONCLUSIONS: For EMG dry-contact electrodes, comparing the performance against gel electrodes for the application with the selected material is important. Other factors recommended to be studied are electrodes' durability and long-term stability.
INTRODUCTION: In recent years, electromyography (EMG) has been increasingly studied for wearable applications. Conventional gel electrodes for electrophysiological recordings have limited use in everyday applications such as prosthetic control or muscular therapy at home. This study investigates the efficacy and feasibility of dry-contact electrode materials employed in smart textiles for EMG recordings. METHODS: Dry-contact electrode materials were selected and implemented on textile substrates. Using these electrodes, EMG was recorded from the forearm of able-bodied subjects. 25% and 50% isometric maximum voluntary contractions were captured. A comparative investigation was performed against gel electrodes, assessing the effect of material properties on signal fidelity and strength compared. RESULTS: When isolating for electrode surface area and pressure, 31 of the 40 materials demonstrated strong positive correlations in their mean PSD with gel electrodes (r > 95, p < 0.001). The inclusion of ionic liquids in the material composition, and using raised or flat electrodes, did not demonstrate a significant effect in signal quality. CONCLUSIONS: For EMG dry-contact electrodes, comparing the performance against gel electrodes for the application with the selected material is important. Other factors recommended to be studied are electrodes' durability and long-term stability.
Authors: Bersain A Reyes; Hugo F Posada-Quintero; Justin R Bales; Amanda L Clement; George D Pins; Albert Swiston; Jarno Riistama; John P Florian; Barbara Shykoff; Michael Qin; Ki H Chon Journal: IEEE Trans Biomed Eng Date: 2014-06 Impact factor: 4.538
Authors: Pierre Leleux; Camryn Johnson; Xenofon Strakosas; Jonathan Rivnay; Thierry Hervé; Róisín M Owens; George G Malliaras Journal: Adv Healthc Mater Date: 2014-03-04 Impact factor: 9.933
Authors: Scott K Lynn; Casey M Watkins; Megan A Wong; Katherine Balfany; Daniel F Feeney Journal: J Sports Sci Med Date: 2018-05-14 Impact factor: 2.988
Authors: Markus Weder; Dirk Hegemann; Martin Amberg; Markus Hess; Luciano F Boesel; Roger Abächerli; Veronika R Meyer; René M Rossi Journal: Sensors (Basel) Date: 2015-01-15 Impact factor: 3.576