Characterization of micromachined spiked biopotential electrodes.

Patrick Griss1, Heli K Tolvanen-Laakso, Pekka Meriläinen, Göran Stemme.   

Abstract

We present the characterization of dry spiked biopotential electrodes and test their suitability to be used in anesthesia monitoring systems based on the measurement of electroencephalographic signals. The spiked electrode consists of an array of microneedles penetrating the outer skin layers. We found a significant dependency of the electrode-skin-electrode impedance (ESEI) on the electrode size (i.e., the number of spikes) and the coating material of the spikes. Electrodes larger than 3 x 3 mm2 coated with Ag-AgCl have sufficiently low ESEI to be well suited for electroencephalograph (EEG) recordings. The maximum measured ESEI was 4.24 k(omega) and 87 k(omega), at 1 kHz and 0.6 Hz, respectively. The minimum ESEI was 0.65 k(omega) an 16 k(omega), at the same frequencies. The ESEI of spiked electrodes is stable over an extended period of time. The arithmetic mean of the generated dc offset voltage is 11.8 mV immediately after application on the skin and 9.8 mV after 20-30 min. A spectral study of the generated potential difference revealed that the ac part was unstable at frequencies below approximately 0.8 Hz. Thus, the signal does not interfere with a number of clinical applications using real-time EEG. Comparing raw EEG recordings of the spiked electrode with commercial Zipprep electrodes showed that both signals were similar. Due to the mechanical strength of the silicon microneedles and the fact that neither skin preparation nor electrolytic gel is required, use of the spiked electrode is convenient. The spiked electrode is very comfortable for the patient.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12046705     DOI: 10.1109/TBME.2002.1001974

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  18 in total

1.  Characteristics of Skin-Electrode Impedance for a Novel Screw Electrode.

Authors:  Wenyan Jia; Jiamin Wu; Di Gao; Mingui Sun
Journal:  Proc IEEE Annu Northeast Bioeng Conf       Date:  2014-04

2.  Fabrication of polymer microneedles using a two-photon polymerization and micromolding process.

Authors:  Shaun D Gittard; Aleksandr Ovsianikov; Nancy A Monteiro-Riviere; Jason Lusk; Pierre Morel; Paola Minghetti; Cristina Lenardi; Boris N Chichkov; Roger J Narayan
Journal:  J Diabetes Sci Technol       Date:  2009-03-01

Review 3.  Dry EEG electrodes.

Authors:  M A Lopez-Gordo; D Sanchez-Morillo; F Pelayo Valle
Journal:  Sensors (Basel)       Date:  2014-07-18       Impact factor: 3.576

Review 4.  Imaging natural cognition in action.

Authors:  Klaus Gramann; Daniel P Ferris; Joseph Gwin; Scott Makeig
Journal:  Int J Psychophysiol       Date:  2013-09-26       Impact factor: 2.997

5.  Fabrication, characterization and applications of graphene electronic tattoos.

Authors:  Dmitry Kireev; Shideh Kabiri Ameri; Alena Nederveld; Jameson Kampfe; Hongwoo Jang; Nanshu Lu; Deji Akinwande
Journal:  Nat Protoc       Date:  2021-04-12       Impact factor: 13.491

Review 6.  Microneedles for drug and vaccine delivery.

Authors:  Yeu-Chun Kim; Jung-Hwan Park; Mark R Prausnitz
Journal:  Adv Drug Deliv Rev       Date:  2012-05-01       Impact factor: 15.470

7.  Gaming control using a wearable and wireless EEG-based brain-computer interface device with novel dry foam-based sensors.

Authors:  Lun-De Liao; Chi-Yu Chen; I-Jan Wang; Sheng-Fu Chen; Shih-Yu Li; Bo-Wei Chen; Jyh-Yeong Chang; Chin-Teng Lin
Journal:  J Neuroeng Rehabil       Date:  2012-01-28       Impact factor: 4.262

8.  A power-efficient bio-potential acquisition device with DS-MDE sensors for long-term healthcare monitoring applications.

Authors:  Chia-Lin Chang; Chih-Wei Chang; Hong-Yi Huang; Chen-Ming Hsu; Chia-Hsuan Huang; Jin-Chern Chiou; Ching-Hsing Luo
Journal:  Sensors (Basel)       Date:  2010-05-11       Impact factor: 3.576

9.  Design, fabrication and experimental validation of a novel dry-contact sensor for measuring electroencephalography signals without skin preparation.

Authors:  Lun-De Liao; I-Jan Wang; Sheng-Fu Chen; Jyh-Yeong Chang; Chin-Teng Lin
Journal:  Sensors (Basel)       Date:  2011-05-30       Impact factor: 3.576

10.  A low-power bio-potential acquisition system with flexible PDMS dry electrodes for portable ubiquitous healthcare applications.

Authors:  Chih-Yuan Chen; Chia-Lin Chang; Chih-Wei Chang; Shin-Chi Lai; Tsung-Fu Chien; Hong-Yi Huang; Jin-Chern Chiou; Ching-Hsing Luo
Journal:  Sensors (Basel)       Date:  2013-03-04       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.