Literature DB >> 24845297

Novel electrodes for underwater ECG monitoring.

Bersain A Reyes, Hugo F Posada-Quintero, Justin R Bales, Amanda L Clement, George D Pins, Albert Swiston, Jarno Riistama, John P Florian, Barbara Shykoff, Michael Qin, Ki H Chon.   

Abstract

We have developed hydrophobic electrodes that provide all morphological waveforms without distortion of an ECG signal for both dry and water-immersed conditions. Our electrode is comprised of a mixture of carbon black powder (CB) and polydimethylsiloxane (PDMS). For feasibility testing of the CB/PDMS electrodes, various tests were performed. One of the tests included evaluation of the electrode-to-skin contact impedance for different diameters, thicknesses, and different pressure levels. As expected, the larger the diameter of the electrodes, the lower the impedance and the difference between the large sized CB/PDMS and the similarly-sized Ag/AgCl hydrogel electrodes was at most 200 kΩ, in favor of the latter. Performance comparison of CB/PDMS electrodes to Ag/AgCl hydrogel electrodes was carried out in three different scenarios: a dry surface, water immersion, and postwater immersion conditions. In the dry condition, no statistical differences were found for both the temporal and spectral indices of the heart rate variability analysis between the CB/PDMS and Ag/AgCl hydrogel (p > 0.05) electrodes. During water immersion, there was significant ECG amplitude reduction with CB/PDMS electrodes when compared to wet Ag/AgCl electrodes kept dry by their waterproof adhesive tape, but the reduction was not severe enough to obscure the readability of the recordings, and all morphological waveforms of the ECG signal were discernible even when motion artifacts were introduced. When water did not penetrate tape-wrapped Ag/AgCl electrodes, high fidelity ECG signals were observed. However, when water penetrated the Ag/AgCl electrodes, the signal quality degraded to the point where ECG morphological waveforms were not discernible.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24845297     DOI: 10.1109/TBME.2014.2309293

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  18 in total

1.  A Novel Antibacterial Membrane Electrode Based on Bacterial Cellulose/Polyaniline/AgNO3 Composite for Bio-Potential Signal Monitoring.

Authors:  Nannan Zhang; Lina Yue; Yajie Xie; Oluwarotimi William Samuel; Olatunji Mumini Omisore; Weihua Pei; Xiao Xing; Chuang Lin; Yudong Zheng; Lei Wang
Journal:  IEEE J Transl Eng Health Med       Date:  2018-08-06       Impact factor: 3.316

2.  VERB: VFCDM-Based Electrocardiogram Reconstruction and Beat Detection Algorithm.

Authors:  Syed Khairul Bashar; Allan J Walkey; David D McManus; Ki H Chon
Journal:  IEEE Access       Date:  2019-01-21       Impact factor: 3.367

Review 3.  Recent Advances in Stretchable and Wearable Capacitive Electrophysiological Sensors for Long-Term Health Monitoring.

Authors:  Hadaate Ullah; Md A Wahab; Geoffrey Will; Mohammad R Karim; Taisong Pan; Min Gao; Dakun Lai; Yuan Lin; Mahdi H Miraz
Journal:  Biosensors (Basel)       Date:  2022-08-11

4.  Assessment of Carbon/Salt/Adhesive Electrodes for Surface Electromyography Measurements.

Authors:  Hugo Posada-Quintero; Ryan Rood; Ken Burnham; John Pennace; Ki Chon
Journal:  IEEE J Transl Eng Health Med       Date:  2016-05-17       Impact factor: 3.316

5.  A robust ECG denoising technique using variable frequency complex demodulation.

Authors:  Md-Billal Hossain; Syed Khairul Bashar; Jesus Lazaro; Natasa Reljin; Yeonsik Noh; Ki H Chon
Journal:  Comput Methods Programs Biomed       Date:  2020-11-21       Impact factor: 5.428

Review 6.  The Current State of Mobile Phone Apps for Monitoring Heart Rate, Heart Rate Variability, and Atrial Fibrillation: Narrative Review.

Authors:  Ka Hou Christien Li; Francesca Anne White; Gary Tse; Timothy Tipoe; Tong Liu; Martin Cs Wong; Aaron Jesuthasan; Adrian Baranchuk; Bryan P Yan
Journal:  JMIR Mhealth Uhealth       Date:  2019-02-15       Impact factor: 4.773

7.  Evaluation of dry textile electrodes for long-term electrocardiographic monitoring.

Authors:  Milad Alizadeh-Meghrazi; Binbin Ying; Alessandra Schlums; Emily Lam; Ladan Eskandarian; Farhana Abbas; Gurjant Sidhu; Amin Mahnam; Bastien Moineau; Milos R Popovic
Journal:  Biomed Eng Online       Date:  2021-07-12       Impact factor: 2.819

8.  Noise-Reducing Fabric Electrode for ECG Measurement.

Authors:  Takamasa Terada; Masahiro Toyoura; Takahide Sato; Xiaoyang Mao
Journal:  Sensors (Basel)       Date:  2021-06-23       Impact factor: 3.576

9.  Graphite Based Electrode for ECG Monitoring: Evaluation under Freshwater and Saltwater Conditions.

Authors:  Tharoeun Thap; Kwon-Ha Yoon; Jinseok Lee
Journal:  Sensors (Basel)       Date:  2016-04-15       Impact factor: 3.576

10.  Analysis of Consistency of Transthoracic Bioimpedance Measurements Acquired with Dry Carbon Black PDMS Electrodes, Adhesive Electrodes, and Wet Textile Electrodes.

Authors:  Hugo F Posada-Quintero; Natasa Reljin; Caitlin Eaton-Robb; Yeonsik Noh; Jarno Riistama; Ki H Chon
Journal:  Sensors (Basel)       Date:  2018-05-26       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.