Adrianna Klajmon1, Aldona Olechowska-Jarząb2, Dominika Salamon3, Agnieszka Sroka-Oleksiak3, Monika Brzychczy-Włoch3, Tomasz Gosiewski3.
Abstract
Diagnostics of the coronavirus disease 2019 (COVID-19) using molecular techniques from the collected respiratory swab specimens requires well-equipped laboratory and qualified personnel, also it needs several hours of waiting for results and is expensive. Antigen tests appear to be faster and cheaper but their sensitivity and specificity are debatable. The aim of this study was to compare a selected antigen test with quantitative polymerase chain reaction (qPCR) tests results. Nasopharyngeal swabs were collected from 192 patients with COVID-19 symptoms. All samples were tested using Vitassay qPCR SARS-CoV-2 kit and the Humasis COVID-19 Ag Test (MedSun) antigen immunochromatographic test simultaneously. Ultimately, 189 samples were tested; 3 samples were excluded due to errors in taking swabs. The qPCR and antigen test results were as follows: 47 positive and 142 negative, and 45 positive and 144 negative, respectively. Calculated sensitivity of 91.5% and specificity of 98.6% for the antigen test shows differences which are not statistically significant in comparison to qPCR. Our study showed that effectiveness of the antigen tests in rapid laboratory diagnostics is high enough to be an alternative and support for nucleic acid amplification tests (NAAT) in the virus replication phase in the course of COVID-19.Entities:
Keywords: COVID-19; NAAT; SARS-CoV-2; antigen test; laboratory diagnostics; qPCR
Mesh:
Substances:
Year: 2021 PMID: 35062221 PMCID: PMC8779007 DOI: 10.3390/v14010017
Source DB: PubMed Journal: Viruses ISSN: 1999-4915 Impact factor: 5.048
Figure 1Swabs collected correctly from nasopharynx—visible ciliary cells (A,B). Swabs collected incorrectly—epidermal cells from the nasal vestibule are visible (C,D). Magnification 600x.
Summary of the results obtained by the qPCR method and the Humasis COVID-19 Ag Test.
| Test Result | qPCR Test | |||
|---|---|---|---|---|
| Positive | Negative | Total | ||
| Humasis COVID-19 Ag Test | Positive | 43 | 2 | 45 |
| Negative | 4 | 140 | 144 | |
| Total | 47 | 142 | 189 | |
Summary of the positive-sample Ct values obtained by the qPCR method and the Humasis COVID-19 Ag Test.
| qPCR Test | ORF 1ab Gene Ct Values | N Gene Ct Values | Humasis COVID-19 Ag Test |
|---|---|---|---|
| Positive | 29.95 | 37.87 | Positive |
| Positive | 15.16 | 21.04 | Positive |
| Positive | 11.49 | 15.56 | Positive |
| Positive | 18.97 | 23.89 | Positive |
| Positive | 11.46 | 15.55 | Positive |
| Positive | 19.60 | 17.90 | Positive |
| Positive | 26.62 | 23.42 | Positive |
| Positive | 24.55 | 39.46 | Positive |
| Positive | 22.97 | 23.93 | Positive |
| Positive | 16.65 | 24.20 | Positive |
| Positive | 31.72 | 32.95 | Positive |
| Positive | 18.47 | 23.72 | Positive |
| Positive | 21.44 | 22.39 | Positive |
| Positive | 20.84 | 21.07 | Positive |
| Positive | 15.64 | 28.48 | Positive |
| Positive | 18.47 | 23.72 | Positive |
| Positive | 21.22 | 21.89 | Positive |
| Positive | 17.72 | 22.90 | Positive |
| Positive | 23.93 | 23.73 | Positive |
| Positive | 16.16 | 19.84 | Positive |
| Positive | 22.19 | 21.38 | Positive |
| Positive | 24.08 | 24.27 | Positive |
| Positive | 30.46 | 24.29 | Positive |
| Positive | 28.04 | 31.07 | Positive |
| Positive | 33.37 | 31.03 | Positive |
| Positive | 30.42 | 24.90 | Positive |
| Positive | 28.31 | 28.11 | Positive |
| Positive | 24.89 | 25.65 | Positive |
| Positive | 24.05 | 26.11 | Positive |
| Positive | 14.35 | 16.64 | Positive |
| Positive | 18.57 | 24.37 | Positive |
| Positive | 22.89 | 24.54 | Positive |
| Positive | 11.95 | 11.56 | Positive |
| Positive | 11.12 | 17.83 | Positive |
| Positive | 22.24 | 24.65 | Positive |
| Positive | 29.76 | 28.20 | Positive |
| Positive | 28.78 | 26.06 | Positive |
| Positive | 17.72 | 22.90 | Positive |
| Positive | 18.37 | 17.48 | Positive |
| Positive | 22.12 | 23.76 | Positive |
| Positive | 19.81 | 24.99 | Positive |
| Positive | 27.25 | 24.35 | Positive |
| Positive | 23.10 | 24.27 | Positive |
| Positive | 31.80 | 23.90 | Negative |
| Positive | 32.81 | 31.02 | Negative |
| Positive | 35.10 | 33.21 | Negative |
| Positive | 34.20 | 33.61 | Negative |
Diagnostic values of the Humasis COVID-19 Ag Test.
| Value | 95% CI | |
|---|---|---|
|
| 91.49% | 79.62–97.63% |
|
| 97.90% | 93.99–99.57% |
|
| 93.48% | 82.10–98.63% |
|
| 97.22% | 93.04–99.24% |
|
| 43.61 | 14.19–134.07 |
|
| 0.09 | 0.03–0.22 |
|
| 96.32% | 92.56–98.51% |
Abbreviations: CI—confidence interval, PPV—positive predictive value, NPV—negative predictive value, LR—likelihood ratio.