Ana Paula Narata1, Laura Obradó2, Raquel Kalé Moyano2, Juan M Macho3, Jordi Blasco3, Antonio López Rueda3, Luis San Roman3, Sebastian Remollo4, Claudia Marinelli5, Rosana Cepeda5, Héctor Fernández2, Ignacio Larrabide2,6.
Abstract
Background: Flow-Diverter (FD) porosity has been pointed as a critical factor in the occlusion of cerebral aneurysms after treatment. Objective: Verification and Validation of computational models in terms of predictive capacity, relating FD porosity and occlusion after cerebral aneurysms treatment.Entities:
Keywords: cerebral aneurysms; device porosity; device sizing; flow diverter; time-to-occlusion
Year: 2021 PMID: 35047944 PMCID: PMC8757794 DOI: 10.3389/fmedt.2021.705003
Source DB: PubMed Journal: Front Med Technol ISSN: 2673-3129
Statistical descriptive data of sample size and FU time by brand.
|
|
|
|
|
|
|
|
| |
|---|---|---|---|---|---|---|---|---|
| Derivo | 8 | 6.84 | 0.57 | 22.14 | 4.90 | 9.00 | 5.10 | 7.80 |
| P64 | 8 | 6.57 | 0.15 | 6.00 | 6.00 | 7.10 | 6.10 | 6.80 |
| Pipeline | 26 | 6.88 | 0.39 | 27.11 | 4.90 | 11.40 | 5.80 | 7.00 |
| Surpass | 22 | 7.21 | 0.54 | 27.89 | 4.70 | 12.40 | 6.60 | 7.50 |
CV, coefficient of variation; FD, Flow-Diverter.
Figure 1Graphical interface of ANKYRAS, presenting the centerline extraction tools and the quantitative analysis visualization (in this case, cross-section perimeter). The interface of ANKYRAS is 100% hosted by a standard web-browser and can be accessed from any operative system.
Figure 2Flow diverter braiding structure, being L the length of the stent at the nominal position and ϕ the nominal diameter of the stent. Right: detailed definition of a unit pore cell, translations and reflections of the unit cell along the surface of the stent covers its whole surface. Being S the constant length of the strut, ω the width of the strut, α the angle with the longitudinal direction of the stent, and Sy and Sy the projections of the wire at the crossing point. A and B are the non-occupied areas of the unit cell.
Figure 3Four sample cases, one for each FD brand used. The first column presents the XA with contrast dilution and the FD. Second column presents the FD highlighted in red. Third column shows the 3D representation of the angiography with the simulated stent implanted at the same distal location as the actual FD. Fourth column shows a close-up of the simulated FD model labeled by porosity. FD, Flow-Diverter.
Figure 4Box-plot of the porosity for each FD, grouped by FD brand. FD, Flow-Diverter.