Literature DB >> 23891312

Newtonian and non-Newtonian blood flow in coiled cerebral aneurysms.

Hernán G Morales1, Ignacio Larrabide, Arjan J Geers, Martha L Aguilar, Alejandro F Frangi.   

Abstract

Endovascular coiling aims to isolate the aneurysm from blood circulation by altering hemodynamics inside the aneurysm and triggering blood coagulation. Computational fluid dynamics (CFD) techniques have the potential to predict the post-operative hemodynamics and to investigate the complex interaction between blood flow and coils. The purpose of this work is to study the influence of blood viscosity on hemodynamics in coiled aneurysms. Three image-based aneurysm models were used. Each case was virtually coiled with a packing density of around 30%. CFD simulations were performed in coiled and untreated aneurysm geometries using a Newtonian and a Non-Newtonian fluid models. Newtonian fluid slightly overestimates the intra-aneurysmal velocity inside the aneurysm before and after coiling. There were numerical differences between fluid models on velocity magnitudes in coiled simulations. Moreover, the non-Newtonian fluid model produces high viscosity (>0.007 [Pas]) at aneurysm fundus after coiling. Nonetheless, these local differences and high-viscous regions were not sufficient to alter the main flow patterns and velocity magnitudes before and after coiling. To evaluate the influence of coiling on intra-aneurysmal hemodynamics, the assumption of a Newtonian fluid can be used.
© 2013 Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CFD; Cerebral aneurysms; Endovascular coiling; Hemodynamics; Non-Newtonian fluid flow

Mesh:

Year:  2013        PMID: 23891312     DOI: 10.1016/j.jbiomech.2013.06.034

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  19 in total

Review 1.  What does computational fluid dynamics tell us about intracranial aneurysms? A meta-analysis and critical review.

Authors:  Khalid M Saqr; Sherif Rashad; Simon Tupin; Kuniyasu Niizuma; Tamer Hassan; Teiji Tominaga; Makoto Ohta
Journal:  J Cereb Blood Flow Metab       Date:  2019-06-18       Impact factor: 6.200

Review 2.  Advances in Biomaterials and Technologies for Vascular Embolization.

Authors:  Jingjie Hu; Hassan Albadawi; Brian W Chong; Amy R Deipolyi; Rahul A Sheth; Ali Khademhosseini; Rahmi Oklu
Journal:  Adv Mater       Date:  2019-06-06       Impact factor: 30.849

3.  Evidence for non-Newtonian behavior of intracranial blood flow from Doppler ultrasonography measurements.

Authors:  Khalid M Saqr; Ossama Mansour; Simon Tupin; Tamer Hassan; Makoto Ohta
Journal:  Med Biol Eng Comput       Date:  2018-12-07       Impact factor: 2.602

4.  Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH)-phase II: rupture risk assessment.

Authors:  Philipp Berg; Samuel Voß; Gábor Janiga; Sylvia Saalfeld; Aslak W Bergersen; Kristian Valen-Sendstad; Jan Bruening; Leonid Goubergrits; Andreas Spuler; Tin Lok Chiu; Anderson Chun On Tsang; Gabriele Copelli; Benjamin Csippa; György Paál; Gábor Závodszky; Felicitas J Detmer; Bong J Chung; Juan R Cebral; Soichiro Fujimura; Hiroyuki Takao; Christof Karmonik; Saba Elias; Nicole M Cancelliere; Mehdi Najafi; David A Steinman; Vitor M Pereira; Senol Piskin; Ender A Finol; Mariya Pravdivtseva; Prasanth Velvaluri; Hamidreza Rajabzadeh-Oghaz; Nikhil Paliwal; Hui Meng; Santhosh Seshadhri; Sreenivas Venguru; Masaaki Shojima; Sergey Sindeev; Sergey Frolov; Yi Qian; Yu-An Wu; Kent D Carlson; David F Kallmes; Dan Dragomir-Daescu; Oliver Beuing
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-05-03       Impact factor: 2.924

5.  Computational study for the effects of coil configuration on blood flow characteristics in coil-embolized cerebral aneurysm.

Authors:  Tomohiro Otani; Satoshi Ii; Tomoyoshi Shigematsu; Toshiyuki Fujinaka; Masayuki Hirata; Tomohiko Ozaki; Shigeo Wada
Journal:  Med Biol Eng Comput       Date:  2016-07-21       Impact factor: 2.602

6.  Accounting for residence-time in blood rheology models: do we really need non-Newtonian blood flow modelling in large arteries?

Authors:  Amirhossein Arzani
Journal:  J R Soc Interface       Date:  2018-09-26       Impact factor: 4.118

7.  Computational and experimental investigation of particulate matter deposition in cerebral side aneurysms.

Authors:  Mark Epshtein; Netanel Korin
Journal:  J R Soc Interface       Date:  2020-08-19       Impact factor: 4.118

8.  Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models.

Authors:  Anderson Chun On Tsang; Simon Sui Man Lai; Wai Choi Chung; Abraham Yik Sau Tang; Gilberto Ka Kit Leung; Alexander Kai Kei Poon; Alfred Cheuk Hang Yu; Kwok Wing Chow
Journal:  Ultrasonography       Date:  2015-01-31

9.  Long-Term Venovenous Connection for Extracorporeal Carbon Dioxide Removal (ECCO2R)-Numerical Investigation of the Connection to the Common Iliac Veins.

Authors:  N B Steuer; K Hugenroth; T Beck; J Spillner; R Kopp; S Reinartz; T Schmitz-Rode; U Steinseifer; G Wagner; J Arens
Journal:  Cardiovasc Eng Technol       Date:  2020-05-13       Impact factor: 2.495

10.  Wall Shear Stress and Flow Patterns in Unruptured and Ruptured Anterior Communicating Artery Aneurysms Using Computational Fluid Dynamics.

Authors:  Ui Yun Lee; Jinmu Jung; Hyo Sung Kwak; Dong Hwan Lee; Gyung Ho Chung; Jung Soo Park; Eun Jeong Koh
Journal:  J Korean Neurosurg Soc       Date:  2018-10-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.