Literature DB >> 21257202

Flow diverter stents in the treatment of intracranial aneurysms: Where are we?

Laurent Pierot1.   

Abstract

Flow diverter stents are devices designed to treat complex aneurysms. According to preliminary series published in the literature, treatment of aneurysms with flow diverters is highly efficacious with acceptable morbidity and mortality. Delayed aneurysm ruptures have been reported but mechanisms are actually not completely elucidated. In-stent thrombosis or stenosis was also observed. Indications of flow diverters are complex aneurysms (fusiform, large and giant, wide neck, small aneurysms untreatable by conventional coiling) as well as recurrences. Several randomized studies and registries are actually in progress and will contribute to a more precise knowledge of the place of the flow diverters in the treatment of intracranial aneurysms.
Copyright © 2011 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21257202     DOI: 10.1016/j.neurad.2010.12.002

Source DB:  PubMed          Journal:  J Neuroradiol        ISSN: 0150-9861            Impact factor:   3.447


  34 in total

1.  The place for remodeling technique and stenting in the endovascular management of intracranial aneurysms: a single-center analysis from 2008 to 2010.

Authors:  Laurent Pierot; Girish Rajpal; Krzysztof Kadziolka; Coralie Barbe
Journal:  Neuroradiology       Date:  2011-11-09       Impact factor: 2.804

2.  Does stent-assisted coiling still have a place in the management of intracranial aneurysms?

Authors:  L Pierot; C Cognard
Journal:  AJNR Am J Neuroradiol       Date:  2013-06-06       Impact factor: 3.825

3.  Effect of flow diversion with silk on aneurysm size: A single center experience.

Authors:  Lee-Anne Slater; Cathy Soufan; Michael Holt; Winston Chong
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

4.  WEB-DL endovascular treatment of wide-neck bifurcation aneurysms: short- and midterm results in a European study.

Authors:  B Lubicz; J Klisch; J-Y Gauvrit; I Szikora; M Leonardi; T Liebig; N P Nuzzi; E Boccardi; F D Paola; M Holtmannspötter; W Weber; E Calgliari; V Sychra; B Mine; L Pierot
Journal:  AJNR Am J Neuroradiol       Date:  2014-01-23       Impact factor: 3.825

5.  WEB intrasaccular flow disruptor-prospective, multicenter experience in 83 patients with 85 aneurysms.

Authors:  C Papagiannaki; L Spelle; A-C Januel; A Benaissa; J-Y Gauvrit; V Costalat; H Desal; F Turjman; S Velasco; X Barreau; P Courtheoux; C Cognard; D Herbreteau; J Moret; L Pierot
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-03       Impact factor: 3.825

Review 6.  Is flow diversion the death of cerebral bypass and coiling/stent-assisted coiling for giant cavernous aneurysms? A critical review on comparative outcomes and ongoing clinical trials.

Authors:  Tobias A Mattei; Andrew S Ferrell; Gavin W Britz
Journal:  Neurosurg Rev       Date:  2013-04-18       Impact factor: 3.042

7.  Retrospective Analysis of Delayed Intraparenchymal Hemorrhage after Flow-Diverter Treatment: Presentation of a Retrospective Multicenter Trial.

Authors:  A Benaissa; C Tomas; F Clarençon; N Sourour; D Herbreteau; L Spelle; S Gallas; A-C Januel; A L Gaultier; L Pierot
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-29       Impact factor: 3.825

8.  WEB Treatment of Intracranial Aneurysms: Clinical and Anatomic Results in the French Observatory.

Authors:  L Pierot; J Moret; F Turjman; D Herbreteau; H Raoult; X Barreau; S Velasco; H Desal; A-C Januel; P Courtheoux; J-Y Gauvrit; C Cognard; A Molyneux; J Byrne; L Spelle
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-29       Impact factor: 3.825

9.  Late recurrence of a completely occluded large intracranial aneurysm treated with a Tubridge flow diverter.

Authors:  Xiaoxi Zhang; Nan Lv; Chi Wang; Wei Cao; Jianmin Liu; Qinghai Huang
Journal:  BMJ Case Rep       Date:  2016-06-21

10.  Treatment for giant fusiform aneurysm located in the cavernous segment of the internal carotid artery using the pipeline embolization device.

Authors:  Se-Yang Oh; Myeong Jin Kim; Bum-Soo Kim; Yong Sam Shin
Journal:  J Korean Neurosurg Soc       Date:  2014-01-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.