Literature DB >> 32179096

Improving MRI's slice selectivity in the presence of strong, metal-derived inhomogeneities.

Gil Farkash1, Gilad Liberman1, Ricardo P Martinho1, Lucio Frydman2.   

Abstract

PURPOSE: To develop schemes that deliver faithful 2D slices near field heterogeneities of the kind arising from non-ferromagnetic metal implants, with reduced artifacts and shorter scan times.
METHODS: An excitation scheme relying on cross-term spatio-temporal encoding (xSPEN) was used as basis for developing the new inhomogeneity-insensitive, slice-selective pulse scheme. The resulting Fully refOCUSED cross-term SPatiotemporal ENcoding (FOCUSED-xSPEN) approach involved four adiabatic sweeps. The method was evaluated in silico, in vitro and in vivo using mice models, and compared against a number of existing and of novel alternatives based on both conventional and swept RF pulses, including an analogous method based on LASER's selectivity spatial selectivity.
RESULTS: Calculations and experiments confirmed that multi-sweep derivatives of xSPEN and LASER can deliver localized excitation profiles, centered at the intended positions and endowed with enhanced immunity to B0 and B1 distortions. This, however, is achieved at the expense of higher SAR than non-swept counterparts. Furthermore, single-shot FOCUSED-xSPEN and LASER profiles covered limited off-resonance ranges. This could be extended to bands covering arbitrary off-resonance values with uniform slice widths, by looping the experiments over a number of scans possessing suitable transmission and reception offsets.
CONCLUSIONS: A series of novel approaches were introduced to select slices near metals, delivering robustness against Bo and B1+ field inhomogeneities.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Adiabatic pulses; Cross-term spatiotemporal encoding; Metal implants; Slice selection; Susceptibility distortions

Mesh:

Substances:

Year:  2020        PMID: 32179096     DOI: 10.1016/j.mri.2020.03.003

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  1 in total

1.  Volumetric and multispectral DWI near metallic implants using a non-linear phase Carr-Purcell-Meiboom-Gill diffusion preparation.

Authors:  Philip K Lee; Daehyun Yoon; Jesse K Sandberg; Shreyas S Vasanawala; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2022-01-11       Impact factor: 4.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.