Julia M Weller1, Friedrich E Kruse2, Theofilos Tourtas2.
Abstract
PURPOSE: This study aimed to evaluate the clinical outcomes up to 10 years after Descemet membrane endothelial keratoplasty (DMEK).Entities:
Keywords: Descemet Membrane Endothelial Keratoplasty (DMEK); Fuchs’ endothelial corneal dystrophy
Mesh:
Year: 2022 PMID: 35000055 PMCID: PMC9156484 DOI: 10.1007/s10792-021-02176-3
Source DB: PubMed Journal: Int Ophthalmol ISSN: 0165-5701 Impact factor: 2.029
Best corrected visual acuity after Descemet membrane endothelial keratoplasty
| Baseline | 1 y | 2 y | 3 y | 4 y | 5 y | 6 y | 7 y | 8 y | 9 y | 10 y | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| BCVA including all eyes | |||||||||||
| Mean ± SD (logMAR) | 0.63 ± 0.43 | 0.19 ± 0.14 | 0.17 ± 0.16 | 0.17 ± 0.15 | 0.16 ± 0.15 | 0.15 ± 0.18 | 0.14 ± 0.18 | 0.15 ± 0.16 | 0.19 ± 0.21 | 0.18 ± 0.20 | 0.13 ± 0.18 |
| Median | 0.52 | 0.20 | 0.10 | 0.10 | 0.10 | 0.10 | 0.10 | 0.10 | 0.20 | 0.10 | 0.10 |
| | 66 | 56 | 56 | 51 | 42 | 40 | 41 | 41 | 54 | 39 | 21 |
| | – | 0.694 | 0.828 | 0.866 | 0.396 | 0.216 | 0.319 | 0.529 | 0.092 | ||
| BCVA excluding eyes with comorbidities | |||||||||||
| Mean ± SD (logMAR) | 0.55 ± 0.37 | 0.15 ± 0.11 | 0.12 ± 0.09 | 0.13 ± 0.10 | 0.11 ± 0.09 | 0.09 ± 0.11 | 0.10 ± 0.11 | 0.10 ± 0.10 | 0.13 ± 0.11 | 0.12 ± 0.12 | 0.10 ± 0.14 |
| Median | 0.40 | 0.16 | 0.10 | 0.10 | 0.10 | 0.10 | 0.10 | 0.10 | 0.10 | 0.10 | 0.10 |
| | 55 | 47 | 45 | 43 | 35 | 32 | 37 | 34 | 45 | 30 | 15 |
| | – | 0.220 | 0.832 | 0.641 | 0.375 | 0.577 | 0.912 | 0.724 | 0.173 | ||
Best-corrected visual acuity before and at follow-up examinations up to 10 years after Descemet membrane endothelial keratoplasty, with and without exclusion of eyes with comorbidities limiting visual outcome. Wilcoxon signed-rank test was used for comparisons of the mean value with the results at the previous follow-up visit
(BCVA = best-corrected visual acuity; SD = standard deviation; logMAR = logarithm of the minimum angle of resolution, y = years)
The significance level was set at 0.05. Significant differences were marked in bold
Endothelial cell density and central corneal thickness after Descemet membrane endothelial keratoplasty
| Baseline | 1 month | 3 months | 1 y | 2 y | 3 y | 4 y | 5 y | 6 y | 7 y | 8 y | 9 y | 10 y | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A) Endothelial cell density | |||||||||||||
| Mean ± SD (cells/mm2) | 2582 ± 212 | 1486 ± 258 | 1456 ± 292 | 1504 ± 275 | 1384 ± 234 | 1377 ± 286 | 1389 ± 299 | 1373 ± 312 | 1107 ± 339 | 759 ± 202 | 739 ± 197 | 744 ± 207 | 729 ± 167 |
| Median | 2510 | 1471 | 1431 | 1494 | 1382 | 1419 | 1384 | 1413 | 1195 | 696 | 691 | 687 | 694 |
| Loss in % | – | 42% | 43% | 42% | 46% | 47% | 46% | 47% | 57% | 71% | 71% | 71% | 72% |
| | 66 | 44 | 58 | 52 | 52 | 47 | 36 | 35 | 35 | 32 | 45 | 39 | 21 |
| | – | 0.368 | 0.116 | 0.061 | 0.786 | 0.496 | 0.136 | 0.683 | 0.407 | 0.826 |
The significance level was set at 0.05. Significant differences were marked in bold
Endothelial cell density and central corneal thickness before and at follow-up examinations up to 10 years after Descemet membrane endothelial keratoplasty. Wilcoxon signed-rank test was used for comparisons of the mean value with the results at the previous follow-up visit
(ECD = endothelial cell density; CCT = central corneal thickness; SD = standard deviation, y = years)