| Literature DB >> 34938110 |
Jun Hong1, Ji-Hua Han1, Hong-Lei Luo1, Ya-Qi Song1.
Abstract
PURPOSE: This study was designed to explore the optimal minimum segment width (MSW) in the intensity-modulated radiotherapy (IMRT) plan for esophageal cancer. PATIENTS AND METHODS: The imaging data of 20 esophageal cancer patients were selected for this study. Four IMRT plans were designed for each patient with MSWs of 0.5, 1.0, 1.5, and 2.0 cm. The conformity index (CI) and homogeneity index (HI) of the planning target volumes (PTV), organs at risk (OARs), control points (CP), monitor units (MU), plan delivery time (DT), and gamma passing rates (GPR) were collected and compared to appraise the treatment plan quality and delivery efficiency.Entities:
Keywords: delivery efficiency; esophageal cancer; intensity-modulated radiotherapy; minimum segment width; plan quality
Year: 2021 PMID: 34938110 PMCID: PMC8687524 DOI: 10.2147/IJGM.S336269
Source DB: PubMed Journal: Int J Gen Med ISSN: 1178-7074
Summary of Clinical and Image Characters
| Characters | N (%) | Mean (SD) |
|---|---|---|
| Sex | 20 | |
| Female | 8 (40.0%) | |
| Male | 12 (60.0%) | |
| Age (years) | 20 | 67.3 (7.39) |
| Clinical stage | 20 | |
| T2N2M0 | 2 (10.0%) | |
| T3N1M0 | 16 (80.0%) | |
| T3N2M0 | 2 (10.0%) | |
| Local | 20 | |
| Mid thorax | 9 (45.0%) | |
| Upper thorax | 11 (55.0%) | |
| Length (cm) | 20 | 5.35 (1.60) |
| VPTV60 (cm3) | 20 | 137 (67.0) |
| VPTV51 (cm3) | 20 | 486 (106) |
| V Llung (cm3) | 20 | 1506 (457) |
| VRlung (cm3) | 20 | 1958 (764) |
Abbreviations: VPTV60, volume of PTV60; VPTV51, volume of PTV51; V Llung, volume of left lung; VRlung, volume of right lung.
The Cost Functions of IMRT Planning for ESCC
| ROIs | Cost Function | Parameter | Iso Constraint |
|---|---|---|---|
| PTV60 | Target penalty | 98% | 60Gy |
| Quadratic Overdose | 63Gy | 100 | |
| PTV51 | Target penalty | 98% | 51Gy |
| Quadratic Overdose | 60Gy Shrink 0.1cm | 30 | |
| Quadratic Overdose | 55Gy Shrink 0.6cm | 100 | |
| Llung | Parallel | 20Gy K=3 | 20 |
| Parallel | 5Gy K=3 | 50 | |
| Rlung | Parallel | 20Gy K=3 | 20 |
| Parallel | 5Gy K=3 | 50 | |
| Spine cord | Maximum dose | NA | 45Gy |
| Heart | Parallel | 30Gy k=3 | 10 |
| Serial | K=3 | 20Gy | |
| PTV51+1cm | Quadratic Overdose | 51Gy Shrink 0.1cm | 30 |
| Quadratic Overdose | 48Gy Shrink 0.3cm | 100 | |
| Serial | K=14 Shrink 0.5cm | 45Gy | |
| Patent | Maximum dose | NA | 66Gy |
| Quadratic Overdose | 30Gy Shrink 3cm | 80 | |
| Serial | K=14 | 35Gy |
Note: PTV51+1cm: were defined as the PTV51 with a 1 cm margin in all directions.
Figure 1Box plot (A) of the parameters of organ at risks (OARs). Forest plot (B) of the OARs between different MSW groups.
Figure 2Box plot (A) of the HI and CI of PTV60 and PTV51. Forest plot (B) of HI and CI of the PTV60 and PTV51 between different MSW groups.
Figure 3Box plot (A) and forest plot (B) of MU, CP and delivery time among different MSW groups.
Figure 4Box plot (A) and forest plot (B) of GPR among different MSW groups.