IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119.

Gary A Ezzell1, Jay W Burmeister, Nesrin Dogan, Thomas J LoSasso, James G Mechalakos, Dimitris Mihailidis, Andrea Molineu, Jatinder R Palta, Chester R Ramsey, Bill J Salter, Jie Shi, Ping Xia, Ning J Yue, Ying Xiao.   

Abstract

AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit = /mean/ + 1.96sigma. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.

Mesh:

Year:  2009        PMID: 19994544     DOI: 10.1118/1.3238104

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  263 in total

1.  Toward a better understanding of the gamma index: Investigation of parameters with a surface-based distance method.

Authors:  Heng Li; Lei Dong; Lifei Zhang; James N Yang; Michael T Gillin; X Ronald Zhu
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Dynamic positioning accuracy of a novel multileaf collimator for volumetric modulated arc therapy.

Authors:  Yuji Nakaguchi; Takeshi Ono; Ryota Onizuka; Masato Maruyama; Yoshinobu Shimohigashi; Yudai Kai
Journal:  Radiol Phys Technol       Date:  2015-11-26

3.  Statistical control process to compare and rank treatment plans in radiation oncology: impact of heterogeneity correction on treatment planning in lung cancer.

Authors:  Abdulhamid Chaikh; Jacques Balosso
Journal:  Transl Lung Cancer Res       Date:  2016-12

4.  Comparison of individual and composite field analysis using array detector for Intensity Modulated Radiotherapy dose verification.

Authors:  Sathiyan Saminathan; Varatharaj Chandraraj; C H Sridhar; Ravikumar Manickam
Journal:  Rep Pract Oncol Radiother       Date:  2012-05-19

5.  FusionArc optimization: a hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy.

Authors:  Martha M Matuszak; Jennifer M Steers; Troy Long; Daniel L McShan; Benedick A Fraass; H Edwin Romeijn; Randall K Ten Haken
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

6.  Simulation for improvement of system sensitivity of radiochromic film dosimetry with different band-pass filters and scanner light intensities.

Authors:  Takeshi Kamomae; Yuki Miyabe; Akira Sawada; Osamu Matoba; Manabu Nakata; Shinsuke Yano; Toru Takakura; Takashi Mizowaki; Akio Itoh; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2011-03-17

7.  Failure mode and effect analysis-based quality assurance for dynamic MLC tracking systems.

Authors:  Amit Sawant; Sonja Dieterich; Michelle Svatos; Paul Keall
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

8.  Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors.

Authors:  Benjamin E Nelms; Heming Zhen; Wolfgang A Tomé
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

9.  Temporal signal stability of KCl:Eu(2+) storage phosphor dosimeters.

Authors:  Zhiyan Xiao; Rachael Hansel; Haijian Chen; Dongsu Du; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

10.  Development of a novel treatment planning test for credentialing rotational intensity-modulated radiotherapy techniques in the UK.

Authors:  Y Tsang; L Ciurlionis; C Clark; K Venables
Journal:  Br J Radiol       Date:  2013-02       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.