Literature DB >> 34938016

Data on dental bite materials with stability and displacement under load.

Harsh Kasabwala1, Subhabrata Maiti1, V Ashok1, Keerthi Sashank1.   

Abstract

It is of interest to document the accuracy, time dependent dimensional stability and displacement to load for 5 types of inter-occlusal recording materials. We used cad bite paste, putty, lab putty, pattern resin and poly tray acrylic material in this study. A total of 25 samples were fabricated to evaluate the accuracy and dimensional stability. The amount of displacement was calculated by applying displacing force on the bite registration materials till they fractured using Instron 3000 UTS machine. Statistical analysis of the data shows that CAD bite paste has the maximum amount of accuracy and dimensional stability whereas pattern resin showed the least amount of displacement to applied force. Thus, we report that CAD bite registration material displayed best results in terms of accuracy and dimensional stability and moderate results in terms of displacement to force.
© 2020 Biomedical Informatics.

Entities:  

Year:  2020        PMID: 34938016      PMCID: PMC8600202          DOI: 10.6026/973206300161145

Source DB:  PubMed          Journal:  Bioinformation        ISSN: 0973-2063


  13 in total

1.  A clinical evaluation of materials for interocclusal registration in centric relation.

Authors:  V O Pagnano; O L Bezzon; M G de Mattos; R F Ribeiro
Journal:  Braz Dent J       Date:  2000

2.  Evaluation of vertical accuracy of interocclusal records.

Authors:  Vassilis K Vergos; Aris-Petros D Tripodakis
Journal:  Int J Prosthodont       Date:  2003 Jul-Aug       Impact factor: 1.681

3.  An experimental study on particular physical properties of several interocclusal recording media. Part II: Linear dimensional change and accompanying weight change.

Authors:  Konstantinos X Michalakis; Argiris Pissiotis; Vassiliki Anastasiadou; Danai Kapari
Journal:  J Prosthodont       Date:  2004-09       Impact factor: 2.752

Review 4.  Principles for selecting interocclusal records for articulation of dentate and partially dentate casts.

Authors:  M A Freilich; J V Altieri; J J Wahle
Journal:  J Prosthet Dent       Date:  1992-08       Impact factor: 3.426

5.  Materials for interocclusal records and their ability to reproduce a 3-dimensional jaw relationship.

Authors:  G Ockert-Eriksson; A Eriksson; P Lockowandt; O Eriksson
Journal:  Int J Prosthodont       Date:  2000 Mar-Apr       Impact factor: 1.681

6.  Accuracy and dimensional stability of elastomeric impression materials.

Authors:  W B Eames; S W Wallace; N B Suway; L B Rogers
Journal:  J Prosthet Dent       Date:  1979-08       Impact factor: 3.426

7.  Properties of interocclusal registration materials.

Authors:  V Lassila; J F McCabe
Journal:  J Prosthet Dent       Date:  1985-01       Impact factor: 3.426

8.  Clinical evaluation of the accuracy of interocclusal recording materials.

Authors:  L Fattore; W F Malone; J L Sandrik; B Mazur; T Hart
Journal:  J Prosthet Dent       Date:  1984-02       Impact factor: 3.426

9.  An experimental study on particular physical properties of several interocclusal recording media. Part I: consistency prior to setting.

Authors:  Konstantinos X Michalakis; Argiris Pissiotis; Vassiliki Anastasiadou; Danai Kapari
Journal:  J Prosthodont       Date:  2004-03       Impact factor: 2.752

10.  A comparative evaluation of dimensional stability of three types of interocclusal recording materials-an in-vitro multi-centre study.

Authors:  Sampath Kumar Tejo; Anil G Kumar; Vivekanand S Kattimani; Priti D Desai; Sandeep Nalla; Krishna Chaitanya K
Journal:  Head Face Med       Date:  2012-10-05       Impact factor: 2.151

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.