Literature DB >> 12956489

Evaluation of vertical accuracy of interocclusal records.

Vassilis K Vergos1, Aris-Petros D Tripodakis.   

Abstract

PURPOSE: The aim of this study was to evaluate four recording materials (polyether, polyvinyl siloxane, acrylic resin, and wax) for their ability to accurately record, maintain, and reproduce the vertical interocclusal relationship.
MATERIALS AND METHODS: A metallic apparatus was used to represent the opposing arches; its epoxy resin duplicate represented the working casts. The vertical discrepancies produced because of the presence of the records were measured both after repositioning them on the metal apparatus and after transferring them onto the casts. Two-way ANOVA was performed.
RESULTS: Closure through the interocclusal recording materials produced small vertical discrepancies ranging from 24 to 74 microm. When repositioned on the apparatus, the vertical discrepancies were greater. The lowest discrepancy was displayed by polyvinyl siloxane (101 microm) and polyether (107 microm), and the greatest was displayed by wax (168 microm). When records were transferred onto casts, the discrepancies were approximately 0.5 mm, without significant differences among materials.
CONCLUSION: Closure through interocclusal recording materials and removal and repositioning of the records on the apparatus produced small vertical discrepancies with clinically insignificant differences between the materials tested. When records of all materials tested were transferred onto casts, vertical discrepancies of approximately 0.5 mm were found, which is of clinical concern.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12956489

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  7 in total

1.  A Comparative Study to Evaluate the Compression Resistance of Different Interocclusal Recording Materials: An In Vitro Study.

Authors:  Rahul Nagrath; Manesh Lahori; Varun Kumar; Varun Gupta
Journal:  J Indian Prosthodont Soc       Date:  2014-07-17

2.  A Comparative Evaluation of Condylar Guidance Value from Radiograph with Interocclusal Records made During Jaw Relation and Try-in: A Pilot Study.

Authors:  Shilpa Shetty; C L Satish Babu; Deepti Tambake; G P Surendra Kumar; Abhishek T Setpal
Journal:  J Indian Prosthodont Soc       Date:  2013-04-11

3.  Data on dental bite materials with stability and displacement under load.

Authors:  Harsh Kasabwala; Subhabrata Maiti; V Ashok; Keerthi Sashank
Journal:  Bioinformation       Date:  2020-12-31

4.  Evaluation and comparison of resistance to compression of various interocclusal recording media: an in vitro study.

Authors:  G S Chandu; Mohd Faisal Khan; S K Mishra; Pooja Asnani
Journal:  J Int Oral Health       Date:  2015-05

5.  Accuracy of several implant bite registration techniques: an in-vitro pilot study.

Authors:  Do-Hyun Park; Ji-Man Park; Jae-Won Choi; Eun-Sook Kang; Eun-Bin Bae; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

6.  A comparative evaluation of dimensional stability of three types of interocclusal recording materials-an in-vitro multi-centre study.

Authors:  Sampath Kumar Tejo; Anil G Kumar; Vivekanand S Kattimani; Priti D Desai; Sandeep Nalla; Krishna Chaitanya K
Journal:  Head Face Med       Date:  2012-10-05       Impact factor: 2.151

7.  An In-Vitro Evaluation of Articulation Accuracy for Digitally Milled Models vs. Conventional Gypsum Casts.

Authors:  Jason D Lee; German O Gallucci; Sang J Lee
Journal:  Dent J (Basel)       Date:  2022-01-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.