Reliability of transcutaneous hemoglobin measurements in an outpatient pediatric clinic.

Shae Margulies1, Molly Posa2, Melissa Fitzgerald2, Stephanie Filipp3, Diane Howell2, Puneet Tung2, Maria Kelly2.   

Abstract

OBJECTIVE: Our study assessed the reliability of a transcutaneous hemoglobin (tcHgb) measurement as compared to a standard capillary hemoglobin (cHgb) measurement in screening for iron deficiency anemia in a single university-based pediatric outpatient clinic.
METHODS: Study participants included all pediatric patients requiring a hemoglobin (Hgb) assessment from July 2019 to June 2020. A tcHgb measurement was attempted on all children who received a cHgb measurement. Additional variables evaluated were age, visit type, gender, insurance type, weight, BMI percentile and presence of comorbid conditions.
RESULTS: Of 777 attempts, both cHgb and tcHgb were obtained in 196 children aged 9 months to 21 years. Attempts were most successful in children > 2 years of age due to finger size and ability to remain still for one to two minutes. The mean cHgb was 12.5 ± 1.5 g/dL, mean tcHgb value 13.1 ± 2.1 g/dL, and the mean difference was 0.6 ± 2.1 g/dL (tcHgb-cHgb). An intraclass correlation coefficient was 0.29. There were no differences with regards to age, visit type, gender, insurance type, weight, BMI percentile and presence of comorbid conditions. Bland-Altman analysis displayed a lack of agreement between the tcHgb and cHgb measurements and tcHgb tended to over-estimate Hgb values when the cHgb was low.
CONCLUSIONS: The measurement of a transcutaneous Hgb is less invasive for pediatric patients but has significant limitations. Smaller children (probe specifications) and movement limited the ability to obtain a tcHgb measurement in ~75% of children tested. Falsely normal tcHgb values occurred due to overestimation of hemoglobin when compared to the traditional cHgb device. The suboptimal sensitivity of the tcHgb device may cause providers to miss a diagnosis of anemia. Future research should compare both methods of Hgb assessment to the gold standard laboratory-analyzed complete blood count and use a smaller probe for children under 2, once available.

Entities:  

Keywords:  Pediatrics; anemia; health supervision; hemoglobin; outpatient; screening

Mesh:

Substances:

Year:  2021        PMID: 34895027      PMCID: PMC8983555          DOI: 10.1080/00325481.2021.2018256

Source DB:  PubMed          Journal:  Postgrad Med        ISSN: 0032-5481            Impact factor:   3.840


  11 in total

1.  Poorer behavioral and developmental outcome more than 10 years after treatment for iron deficiency in infancy.

Authors:  B Lozoff; E Jimenez; J Hagen; E Mollen; A W Wolf
Journal:  Pediatrics       Date:  2000-04       Impact factor: 7.124

2.  Can noninvasive hemoglobin measurement reduce the need for preoperative venipuncture in pediatric outpatient surgery?

Authors:  Ruifeng Zeng; Christer H Svensen; Husong Li; Ximou Xu; Agneta Skoog Svanberg; Huacheng Liu; Yanrong Li; Wangning Shangguan; Qingquan Lian
Journal:  Paediatr Anaesth       Date:  2017-09-20       Impact factor: 2.556

3.  The REDCap consortium: Building an international community of software platform partners.

Authors:  Paul A Harris; Robert Taylor; Brenda L Minor; Veida Elliott; Michelle Fernandez; Lindsay O'Neal; Laura McLeod; Giovanni Delacqua; Francesco Delacqua; Jacqueline Kirby; Stephany N Duda
Journal:  J Biomed Inform       Date:  2019-05-09       Impact factor: 6.317

4.  Accuracy of Point-of-Care Testing for Anemia in the Emergency Department.

Authors:  Zachary T Osborn; Nuria Villalba; Pamela R Derickson; Thomas P Sewatsky; Abigail P Wager; Kalev Freeman
Journal:  Respir Care       Date:  2019-03-26       Impact factor: 2.258

5.  Noninvasive hemoglobin measurement in pediatric trauma patients.

Authors:  Mark Leo Ryan; Angela C Maxwell; Lisa Manning; Jonathan D Jacobs; Marielena Bachier-Rodriguez; Alexander Feliz; Regan F Williams
Journal:  J Trauma Acute Care Surg       Date:  2016-12       Impact factor: 3.313

Review 6.  Iron deficiency in infants and toddlers in the United States.

Authors:  Alvin N Eden; Claudio Sandoval
Journal:  Pediatr Hematol Oncol       Date:  2012-10-02       Impact factor: 1.969

7.  Iron states and cognitive abilities in young adults: neuropsychological and neurophysiological assessment.

Authors:  Eman Khedr; Sherifa A Hamed; Esam Elbeih; Hala El-Shereef; Yousreyia Ahmad; Safaa Ahmed
Journal:  Eur Arch Psychiatry Clin Neurosci       Date:  2008-06-20       Impact factor: 5.270

8.  Accuracy of noninvasive and invasive point-of-care total blood hemoglobin measurement in an outpatient setting.

Authors:  Marina Raikhel
Journal:  Postgrad Med       Date:  2012-07       Impact factor: 3.840

9.  Evaluation of a Noninvasive Hemoglobin Measurement Device to Screen for Anemia in Infancy.

Authors:  Daniel P Hsu; Alicia J French; Samuel L Madson; John M Palmer; Vinod Gidvani-Diaz
Journal:  Matern Child Health J       Date:  2016-04

10.  Validity of non-invasive point-of-care hemoglobin estimation in healthy and sick children-a method comparison study.

Authors:  Aditya Bhat; Amit Upadhyay; Vijay Jaiswal; Deepak Chawla; Dharamveer Singh; Mithilesh Kumar; C P Yadav
Journal:  Eur J Pediatr       Date:  2015-08-19       Impact factor: 3.183