| Literature DB >> 34861859 |
César F Cayo-Rojas1,2, Karen K Hernández-Caba3, Ana S Aliaga-Mariñas3, Marysela I Ladera-Castañeda4,3, Luis A Cervantes-Ganoza5.
Abstract
BACKGROUND: The contraction presented by resin composites causes an increase in stress at the tooth-resin interface, causing micro-gaps that allow microleakage. This study aims to evaluate the degree of in vitro marginal microleakage in class II restorations with two bulk fill resin composites compared to a conventional nanohybrid resin composite.Entities:
Keywords: Composite resin; Marginal adaptation; Microleakage; Molar; Mono incremental resin; Monoblock resin; Silver nitrate; Thermal cycling; Tooth preparation
Mesh:
Substances:
Year: 2021 PMID: 34861859 PMCID: PMC8642901 DOI: 10.1186/s12903-021-01942-0
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Fig. 1Class II cavity preparation. a Crown sectioned lengthwise (mesiodistal direction). b Proximal view
Fig. 2Marginal microleakage of bulk fill resin composites. a Score 0 (No penetration), b Score 1 (Penetration into the enamel of cavity wall), c Score 2 (Penetration into the dentin of cavity wall without including the pulpal wall of the cavity), d Score 3 (Penetration including the pulpal wall of the cavity)
Marginal microfiltration score in the occlusal and cervical area according to each type of resin evaluated
| Resin composites | Area | Score 0 | Score 1 | Score 2 | Score 3 | Total | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| f | % | f | % | f | % | f | % | N | % | ||
| Filtek Bulk Fill | Occlusal | 8 | 80% | 1 | 10% | 0 | 0% | 1 | 10% | 10 | 100% |
| Cervical | 5 | 50% | 3 | 30% | 2 | 20% | 0 | 0% | 10 | 100% | |
| Tetric N-Ceram Bulk Fill | Occlusal | 3 | 30% | 7 | 70% | 0 | 0% | 0 | 0% | 10 | 100% |
| Cervical | 1 | 10% | 5 | 50% | 3 | 30% | 1 | 10% | 10 | 100% | |
| Filtek Z350 XT | Occlusal | 4 | 40% | 3 | 30% | 3 | 30% | 0 | 0% | 10 | 100% |
| Cervical | 2 | 20% | 6 | 60% | 1 | 10% | 1 | 10% | 10 | 100% | |
f: absolute frequency; n: sample size
Central tendency measurement of the degree of marginal microleakage in resin composites according to the treatment area
| Resin composites | Area | Median | (IQR) | Range | p-value* |
|---|---|---|---|---|---|
| Filtek Bulk Fill | Occlusal | 0 | 3 | 0.149 | |
| Tetric N-ceram bulk fill | 1 | (1) | 1 | ||
| Filtek Z350 XT | 1 | (2) | 2 | ||
| Filtek bulk fill | Cervical | 0.50 | (1) | 2 | 0.180 |
| Tetric N-ceram bulk fill | 1 | (1) | 3 | ||
| Filtek Z350 XT | 1 | (1) | 3 |
IQR: Interquartile Range; *Based on the non-parametric Kruskal–Wallis test for individual samples; * Statistically significant difference p < 0.05
Central tendency measurement of the degree of marginal microleakage in each treatment area according to the type of resin composite applied
| Resin composites | Area | Median | (IQR) | Range | p-value* |
|---|---|---|---|---|---|
| Filtek Bulk Fill | Occlusal | 0 | (0) | 3 | 0.315 |
| Cervical | 0.50 | (1) | 2 | ||
| Tetric N-Ceram Bulk Fill | Occlusal | 1 | (1) | 1 | 0.075 |
| Cervical | 1 | (1) | 3 | ||
| Filtek Z350 XT | Occlusal | 1 | (2) | 2 | 0.684 |
| Cervical | 1 | (1) | 3 |
IQR: Interquartile Range; *Based on the non-parametric Mann–Whitney U test for individual samples; *Statistically significant difference p < 0.05