Literature DB >> 28402730

Light-emitting Diode Beam Profile and Spectral Output Influence on the Degree of Conversion of Bulk Fill Composites.

M G Rocha, Dcrs de Oliveira, I C Correa, L Correr-Sobrinho, Mac Sinhoreti, J L Ferracane, A B Correr.   

Abstract

OBJECTIVES: To evaluate the beam profile and the spectral output of monowave and polywave light-emitting diodes (LEDs) and their influence on the degree of conversion (DC) of bulk fill composites.
METHODS: A monowave LED (Smartlite Focus, Dentsply) and a polywave LED (Valo Cordless, Ultradent) were characterized using a resin calibrator and a laser beam profile analyzer. Two bulk fill composites, Sonic Fill 2 (SF) containing camphorquinone (CQ) and Tetric EvoCeram Bulk Fill (TEB) containing CQ associated with alternative photoinitiators, were placed in custom-designed molds (n=3) and photoactivated by the monowave or polywave LED with 20 J/cm2. To map the DC, longitudinal cross sections (0.5 mm thick) from the center of the restoration were evaluated using FT-NIR microscopy. SF and TEB light transmittances (n=3) through 4-mm-thick specimens were evaluated during curing. Data were analyzed using a split-plot analysis of variance and Tukey test (α=0.05; β=0.2).
RESULTS: The monowave LED had a radiant emittance of 20 ± 0.5 J/cm2 over 420-495 nm, and the polywave LED had an emittance of 15.5 ± 0.4 J/cm2 over 420-495 nm and of 4.5 ± 0.2 J/cm2 over 380-420 nm. The total radiant exposure at the bottom of TEB was 2.2 ± 0.2 J/cm2 with the monowave LED and 1.6 ± 0.3 J/cm2 with the polywave LED, and for SF it was 0.4 ± 0.1 J/cm2 for both LEDs. There were no differences in the curing profiles produced either by the monowave or the polywave LED (p=0.9), according to the regions under influence of blue and/or violet emission at the same depth. There was no statistical difference in the DC for SF using the monowave or polywave LED at any depth (p=0.29). TEB had a higher DC at up to 2 mm in depth when the polywave LED was used (p<0.004), but no differences were found when starting at 2.5 mm.
CONCLUSIONS: Monowave and polywave LEDs emitted nonhomogeneous light beams, but this did not affect the DC homogeneity of bulk fill composites. For composites containing CQ associated with alternative photoinitiators, polywave LEDs had a higher DC, but only at the top part of the restoration; lower wavelength absorption photoinitiators were ineffective in deeper areas.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28402730     DOI: 10.2341/16-164-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  9 in total

1.  Effect of dental headlights spectrum on the polymerization and working time of light-cured resin composites.

Authors:  Mateus-Garcia Rocha; Marc-Edward Ottenga; Panagiotis Zoidis; Stefany Pontes; Andre-Figueiredo Reis; Dayane Oliveira
Journal:  J Clin Exp Dent       Date:  2022-06-01

2.  Comparative Evaluation of Bulk-Fill Composite Resins: Knoop Microhardness, Diametral Tensile Strength and Degree of Conversion.

Authors:  Bruna Scarcello Strini; Joyce Figueiredo de Lima Marques; Renata Pereira; Danielle Ferreira Sobral-Souza; Vanessa Gallego Arias Pecorari; Priscila Christiane Suzy Liporoni; Flávio Henrique Baggio Aguiar
Journal:  Clin Cosmet Investig Dent       Date:  2022-08-04

3.  Evaluation of the influence of light-curing units on the degree of conversion in depth of a bulk-fill resin.

Authors:  Fernanda-Midori Tsuzuki; Lidiane-Vizioli de Castro-Hoshino; Larissa-Coelho-Pires Lopes; Francielle Sato; Mauro-Luciano Baesso; Raquel-Sano-Suga Terada
Journal:  J Clin Exp Dent       Date:  2020-12-01

4.  Evaluation of microhardness, sorption, solubility, and color stability of bulk fill resins: A comparative study.

Authors:  Luís-Felipe Espíndola-Castro; Márcia-de Almeida Durão; Tacyandra-Victória-Gomes Pereira; Ayanne-Karine-de Barros Cordeiro; Gabriela-Queiroz-de Melo Monteiro
Journal:  J Clin Exp Dent       Date:  2020-11-01

5.  On the inaccuracies of dental radiometers.

Authors:  Adrian C Shortall; Mohammed A Hadis; William M Palin
Journal:  PLoS One       Date:  2021-01-29       Impact factor: 3.240

6.  Microleakage in class II restorations of two bulk fill resin composites and a conventional nanohybrid resin composite: an in vitro study at 10,000 thermocycles.

Authors:  César F Cayo-Rojas; Karen K Hernández-Caba; Ana S Aliaga-Mariñas; Marysela I Ladera-Castañeda; Luis A Cervantes-Ganoza
Journal:  BMC Oral Health       Date:  2021-12-04       Impact factor: 2.757

7.  Beam Profiling of Dental Light Curing Units Using Different Camera-Based Systems.

Authors:  Mateus Garcia Rocha; Dayane Oliveira; Christopher Felix; Jean-François Roulet; Mário Alexandre Coelho Sinhoreti; Américo Bortolazzo Correr
Journal:  Eur J Dent       Date:  2021-08-27

8.  Clinical Performance of Bulk-Fill Resin Composite Restorations Using the United States Public Health Service and Federation Dentaire Internationale Criteria: A 12-Month Randomized Clinical Trial.

Authors:  Márcia de Almeida Durão; Ana Karina Maciel de Andrade; Maria do Carmo Moreira da Silva Santos; Marcos Antônio Japiassú Resende Montes; Gabriela Queiroz de Melo Monteiro
Journal:  Eur J Dent       Date:  2020-11-26

9.  Effect of combining photoinitiators on cure efficiency of dental resin-based composites.

Authors:  Lucas Lara; Mateus Garcia Rocha; Livia Rodrigues de Menezes; Américo Bortolazzo Correr; Mario Alexandre Coelho Sinhoreti; Dayane Oliveira
Journal:  J Appl Oral Sci       Date:  2021-07-23       Impact factor: 2.698

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.