Literature DB >> 34842849

Generation of Vertebra Micro-CT-like Image from MDCT: A Deep-Learning-Based Image Enhancement Approach.

Dan Jin1, Han Zheng2, Qingqing Zhao1, Chunjie Wang1, Mengze Zhang1, Huishu Yuan1.   

Abstract

This paper proposes a deep-learning-based image enhancement approach that can generate high-resolution micro-CT-like images from multidetector computed tomography (MDCT). A total of 12,500 MDCT and micro-CT image pairs were obtained from 25 vertebral specimens. Then, a pix2pixHD model was trained and evaluated using the structural similarity index measure (SSIM) and Fréchet inception distance (FID). We performed subjective assessments of the micro-CT-like images based on five aspects. Micro-CT and micro-CT-like image-derived trabecular bone microstructures were compared, and the underlying correlations were analyzed. The results showed that the pix2pixHD method (SSIM, 0.804 ± 0.037 and FID, 43.598 ± 9.108) outperformed the two control methods (pix2pix and CRN) in enhancing MDCT images (p < 0.05). According to the subjective assessment, the pix2pixHD-derived micro-CT-like images showed no significant difference from the micro-CT images in terms of contrast and shadow (p > 0.05) but demonstrated slightly lower noise, sharpness and trabecular bone texture (p < 0.05). Compared with the trabecular microstructure parameters of micro-CT images, those of pix2pixHD-derived micro-CT-like images showed no significant differences in bone volume fraction (BV/TV) (p > 0.05) and significant correlations in trabecular thickness (Tb.Th) and trabecular spacing (Tb.Sp) (Tb.Th, R = 0.90, p < 0.05; Tb.Sp, R = 0.88, p < 0.05). The proposed method can enhance the resolution of MDCT and obtain micro-CT-like images, which may provide new diagnostic criteria and a predictive basis for osteoporosis and related fractures.

Entities:  

Keywords:  computed tomography; deep learning; osteoporosis; structure analysis; trabecular bone; vertebra

Mesh:

Year:  2021        PMID: 34842849      PMCID: PMC8628970          DOI: 10.3390/tomography7040064

Source DB:  PubMed          Journal:  Tomography        ISSN: 2379-1381


  18 in total

Review 1.  Role of magnetic resonance for assessing structure and function of trabecular bone.

Authors:  Felix W Wehrli; Punam K Saha; Bryon R Gomberg; Hee Kwon Song; Peter J Snyder; Maria Benito; Alex Wright; Richard Weening
Journal:  Top Magn Reson Imaging       Date:  2002-10

2.  Comparison of micro-CT and cone beam CT on the feasibility of assessing trabecular structures in mandibular condyle.

Authors:  Xin Liang; Zuyan Zhang; Jianping Gu; Zhihui Wang; Bart Vandenberghe; Reinhilde Jacobs; Jie Yang; Guowu Ma; Haibin Ling; Xuchen Ma
Journal:  Dentomaxillofac Radiol       Date:  2017-04-26       Impact factor: 2.419

Review 3.  Clinical considerations for spinal surgery in the osteoporotic patient: A comprehensive review.

Authors:  S McCoy; F Tundo; S Chidambaram; A A Baaj
Journal:  Clin Neurol Neurosurg       Date:  2019-03-11       Impact factor: 1.876

4.  Fiji: an open-source platform for biological-image analysis.

Authors:  Johannes Schindelin; Ignacio Arganda-Carreras; Erwin Frise; Verena Kaynig; Mark Longair; Tobias Pietzsch; Stephan Preibisch; Curtis Rueden; Stephan Saalfeld; Benjamin Schmid; Jean-Yves Tinevez; Daniel James White; Volker Hartenstein; Kevin Eliceiri; Pavel Tomancak; Albert Cardona
Journal:  Nat Methods       Date:  2012-06-28       Impact factor: 28.547

Review 5.  Pedicle screw augmentation in osteoporotic spine: indications, limitations and technical aspects.

Authors:  S Hoppe; M J B Keel
Journal:  Eur J Trauma Emerg Surg       Date:  2016-12-19       Impact factor: 3.693

Review 6.  Influence of osteoporosis on fracture fixation--a systematic literature review.

Authors:  J Goldhahn; N Suhm; S Goldhahn; M Blauth; B Hanson
Journal:  Osteoporos Int       Date:  2008-06       Impact factor: 4.507

7.  Effects of bone mineral density on pedicle screw fixation.

Authors:  T L Halvorson; L A Kelley; K A Thomas; T S Whitecloud; S D Cook
Journal:  Spine (Phila Pa 1976)       Date:  1994-11-01       Impact factor: 3.468

8.  A comparative study of trabecular bone micro-structural measurements using different CT modalities.

Authors:  Indranil Guha; Benjamin Klintström; Eva Klintström; Xiaoliu Zhang; Örjan Smedby; Rodrigo Moreno; Punam K Saha
Journal:  Phys Med Biol       Date:  2020-11-27       Impact factor: 3.609

9.  ImageJ2: ImageJ for the next generation of scientific image data.

Authors:  Curtis T Rueden; Johannes Schindelin; Mark C Hiner; Barry E DeZonia; Alison E Walter; Ellen T Arena; Kevin W Eliceiri
Journal:  BMC Bioinformatics       Date:  2017-11-29       Impact factor: 3.169

View more