Literature DB >> 34795015

Radioembolization Dosimetry with Total-Body 90Y PET.

Gustavo Costa1, Benjamin Spencer2, Negar Omidvari2, Cameron Foster3, Michael Rusnak3, Heather Hunt3, Denise T Caudle3, Rex T Pillai3, Catherine Tram Vu3, Emilie Roncali2,3.   

Abstract

Transarterial radioembolization (TARE) is a locoregional radiopharmaceutical therapy based on the delivery of radioactive 90Y microspheres to liver tumors. The importance of personalized dosimetry to make TARE safer and more effective has been demonstrated in recent clinical studies, stressing the need for quantification of the dose-response relationship to ultimately optimize the administered activity before treatment and image it after treatment. 90Y dosimetric studies are challenging because of the lack of accurate and precise methods but are best realized with PET combined with Monte Carlo simulations and other image modalities to calculate a segmental dose distribution. The aim of this study was to assess the suitability of imaging 90Y PET patients with the total-body PET/CT uEXPLORER and to investigate possible improvements in TARE 90Y PET-based dosimetry. The uEXPLORER is the first commercially available ultra-high-resolution (171 cps/kBq) total-body digital PET/CT device with a 194-cm axial PET field of view that enables the whole body to be scanned at a single bed position.
Methods: Two PET/CT scanners were evaluated in this study: the Biograph mCT and the total-body uEXPLORER. Images of a National Electrical Manufacturers Association (NEMA) image-quality phantom and 2 patients were reconstructed using our standard clinical oncology protocol. A late portal phase contrast-enhanced CT scan was used to contour the liver segments and create corresponding volumes of interest. To calculate the absorbed dose, Monte Carlo simulations were performed using Geant4 Application for Tomographic Emission (GATE). The absorbed dose and dose-volume histograms were calculated for all 6 spheres (diameters ranging from 10 to 37 mm) of the NEMA phantom, the liver segments, and the entire liver. Differences between the phantom doses and an analytic ground truth were quantified through the root mean squared error.
Results: The uEXPLORER showed a higher signal-to-noise ratio at 10- and 13-mm diameters, consistent with its high spatial resolution and system sensitivity. The total liver-absorbed dose showed excellent agreement between the uEXPLORER and the mCT for both patients, with differences lower than 0.2%. Larger differences of up to 60% were observed when comparing the liver segment doses. All dose-volume histograms were in good agreement, with narrower tails for the uEXPLORER in all segments, indicating lower image noise.
Conclusion: This patient study is compelling for the use of total-body 90Y PET for liver dosimetry. The uEXPLORER scanner showed a better signal-to-noise ratio than mCT, especially in lower-count regions of interest, which is expected to improve dose quantification and tumor dosimetry.
© 2022 by the Society of Nuclear Medicine and Molecular Imaging.

Entities:  

Keywords:  90Y; Monte Carlo simulation; microspheres; personalized medicine; radioembolization; radionuclide therapy

Mesh:

Substances:

Year:  2021        PMID: 34795015      PMCID: PMC9258581          DOI: 10.2967/jnumed.121.263145

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   11.082


  31 in total

1.  Dosimetry based on 99mTc-macroaggregated albumin SPECT/CT accurately predicts tumor response and survival in hepatocellular carcinoma patients treated with 90Y-loaded glass microspheres: preliminary results.

Authors:  Etienne Garin; Laurence Lenoir; Yan Rolland; Julien Edeline; Habiba Mesbah; Sophie Laffont; Philippe Porée; Bruno Clément; Jean-Luc Raoul; E Boucher
Journal:  J Nucl Med       Date:  2012-02       Impact factor: 10.057

2.  Physical and clinical performance of the mCT time-of-flight PET/CT scanner.

Authors:  B W Jakoby; Y Bercier; M Conti; M E Casey; B Bendriem; D W Townsend
Journal:  Phys Med Biol       Date:  2011-03-22       Impact factor: 3.609

Review 3.  Anatomy of the liver: an outline with three levels of complexity--a further step towards tailored territorial liver resections.

Authors:  Pietro Majno; Gilles Mentha; Christian Toso; Philippe Morel; Heinz O Peitgen; Jean H D Fasel
Journal:  J Hepatol       Date:  2013-11-06       Impact factor: 25.083

4.  A gate evaluation of the sources of error in quantitative 90Y PET.

Authors:  Jared Strydhorst; Thomas Carlier; Arnaud Dieudonné; Maurizio Conti; Irène Buvat
Journal:  Med Phys       Date:  2016-10       Impact factor: 4.071

5.  Personalized Dosimetry for Liver Cancer Y-90 Radioembolization Using Computational Fluid Dynamics and Monte Carlo Simulation.

Authors:  Emilie Roncali; Amirtahà Taebi; Cameron Foster; Catherine Tram Vu
Journal:  Ann Biomed Eng       Date:  2020-01-31       Impact factor: 3.934

6.  Segmental Yttrium-90 Radioembolization versus Segmental Chemoembolization for Localized Hepatocellular Carcinoma: Results of a Single-Center, Retrospective, Propensity Score-Matched Study.

Authors:  Siddharth A Padia; Guy E Johnson; Kathryn J Horton; Christopher R Ingraham; Matthew J Kogut; Sharon Kwan; Sandeep Vaidya; Wayne L Monsky; James O Park; Renuka Bhattacharya; Daniel S Hippe; William P Harris
Journal:  J Vasc Interv Radiol       Date:  2017-03-30       Impact factor: 3.464

7.  SIRveNIB: Selective Internal Radiation Therapy Versus Sorafenib in Asia-Pacific Patients With Hepatocellular Carcinoma.

Authors:  Pierce K H Chow; Mihir Gandhi; Say-Beng Tan; Maung Win Khin; Ariunaa Khasbazar; Janus Ong; Su Pin Choo; Peng Chung Cheow; Chanisa Chotipanich; Kieron Lim; Laurentius A Lesmana; Tjakra W Manuaba; Boon Koon Yoong; Aloysius Raj; Chiong Soon Law; Ian H Y Cua; Rolley R Lobo; Catherine S C Teh; Yun Hwan Kim; Yun Won Jong; Ho-Seong Han; Si-Hyun Bae; Hyun-Ki Yoon; Rheun-Chuan Lee; Chien-Fu Hung; Cheng-Yuan Peng; Po-Chin Liang; Adam Bartlett; Kenneth Y Y Kok; Choon-Hua Thng; Albert Su-Chong Low; Anthony S W Goh; Kiang Hiong Tay; Richard H G Lo; Brian K P Goh; David C E Ng; Ganesh Lekurwale; Wei Ming Liew; Val Gebski; Kenneth S W Mak; Khee Chee Soo
Journal:  J Clin Oncol       Date:  2018-03-02       Impact factor: 44.544

Review 8.  90Y-Loaded Microsphere SIRT of HCC Patients With Portal Vein Thrombosis: High Clinical Impact of 99mTc-MAA SPECT/CT-Based Dosimetry.

Authors:  Etienne Garin; Yan Rolland; Julien Edeline
Journal:  Semin Nucl Med       Date:  2019-02-07       Impact factor: 4.446

9.  Quantitative analysis of respiration-induced motion of each liver segment with helical computed tomography and 4-dimensional computed tomography.

Authors:  Yu-Lun Tsai; Ching-Jung Wu; Suzun Shaw; Pei-Chieh Yu; Hsin-Hua Nien; Louis Tak Lui
Journal:  Radiat Oncol       Date:  2018-04-02       Impact factor: 3.481

10.  Yttrium-90 Radioembolization for the Treatment of Solitary, Unresectable HCC: The LEGACY Study.

Authors:  Riad Salem; Guy E Johnson; Edward Kim; Ahsun Riaz; Vivian Bishay; Eveline Boucher; Kirk Fowers; Robert Lewandowski; Siddharth A Padia
Journal:  Hepatology       Date:  2021-06-11       Impact factor: 17.425

View more
  1 in total

1.  The Impact of Injection Distance to Bifurcations on Yttrium-90 Distribution in Liver Cancer Radioembolization.

Authors:  Amirtahà Taebi; Nursultan Janibek; Roger Goldman; Rex Pillai; Catherine T Vu; Emilie Roncali
Journal:  J Vasc Interv Radiol       Date:  2022-03-15       Impact factor: 3.682

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.