Literature DB >> 34744520

Wearable Transcutaneous CO2 Monitor Based on Miniaturized Nondispersive Infrared Sensor.

Vishal Varun Tipparaju1, Sabrina Jimena Mora1, Jingjing Yu1, Francis Tsow1, Xiaojun Xian1.   

Abstract

Transcutaneous oxygen and carbon dioxide provide the status of pulmonary gas exchange and are of importance in diagnosis and management of respiratory diseases. Though significant progress has been made in oximetry, not much has been explored in developing wearable technologies for continuous monitoring of transcutaneous carbon dioxide. This research reports the development of a truly wearable sensor for continuous monitoring of transcutaneous carbon dioxide using miniaturized nondispersive infrared sensor augmented by hydrophobic membrane to address the humidity interference. The wearable transcutaneous CO2 monitor shows well-behaved response curve to humid CO2 with linear response to CO2 concentration. The profile of transcutaneous CO2 monitored by the wearable device correlates well with the end-tidal CO2 trend in human test. The feasibility of the wearable device for passive and unobstructed tracking of transcutaneous CO2 in free-living conditions has also been demonstrated in field test. The wearable transcutaneous CO2 monitoring technology developed in this research can be widely used in remote assessment of pulmonary gas exchange efficiency for patients with respiratory diseases, such as COVID-19, sleep apnea, and chronic obstructive pulmonary disease (COPD).

Entities:  

Keywords:  Arterial Blood Gases; End-Tidal CO2; Nondispersive Infrared (NDIR) Sensor; Respiratory Diseases; Transcutaneous CO2; Wearable; Wristband

Year:  2021        PMID: 34744520      PMCID: PMC8570579          DOI: 10.1109/jsen.2021.3081696

Source DB:  PubMed          Journal:  IEEE Sens J        ISSN: 1530-437X            Impact factor:   4.325


  36 in total

1.  Transcutaneous monitoring as a replacement for arterial PCO(2) monitoring during nocturnal non-invasive ventilation.

Authors:  Jan Hendrik Storre; Friederike Sophie Magnet; Michael Dreher; Wolfram Windisch
Journal:  Respir Med       Date:  2010-10-28       Impact factor: 3.415

2.  Neonatal pulse oximetry: accuracy and reliability.

Authors:  W W Hay; J M Brockway; M Eyzaguirre
Journal:  Pediatrics       Date:  1989-05       Impact factor: 7.124

3.  Validation of a transcutaneous CO(2) monitor in adult patients with chronic respiratory failure.

Authors:  A Hazenberg; J G Zijlstra; H A M Kerstjens; P J Wijkstra
Journal:  Respiration       Date:  2011-01-15       Impact factor: 3.580

Review 4.  Transcutaneous carbon dioxide monitoring in infants and children.

Authors:  Joseph D Tobias
Journal:  Paediatr Anaesth       Date:  2009-02-19       Impact factor: 2.556

5.  Electrochemical sensor for continuous transcutaneous PCO2 measurement.

Authors:  A V Beran; R F Huxtable; D R Sperling
Journal:  J Appl Physiol       Date:  1976-09       Impact factor: 3.531

6.  Transcutaneous and end-tidal carbon dioxide pressures should be measured during pediatric polysomnography.

Authors:  A Morielli; D Desjardins; R T Brouillette
Journal:  Am Rev Respir Dis       Date:  1993-12

7.  Correlation of end-tidal CO2 measurements to arterial PaCO2 in nonintubated patients.

Authors:  C W Barton; E S Wang
Journal:  Ann Emerg Med       Date:  1994-03       Impact factor: 5.721

8.  Early Detection of Silent Hypoxia in Covid-19 Pneumonia Using Smartphone Pulse Oximetry.

Authors:  Jason Teo
Journal:  J Med Syst       Date:  2020-06-19       Impact factor: 4.460

9.  Prehospital pulse oximetry: a red flag for early detection of silent hypoxemia in COVID-19 patients.

Authors:  Romain Jouffroy; Daniel Jost; Bertrand Prunet
Journal:  Crit Care       Date:  2020-06-08       Impact factor: 9.097

10.  Correlating arterial blood gas, acid-base and blood pressure abnormalities with outcomes in COVID-19 intensive care patients.

Authors:  Morne C Bezuidenhout; Owen J Wiese; Desiree Moodley; Elizna Maasdorp; Mogamat R Davids; Coenraad Fn Koegelenberg; Usha Lalla; Aye A Khine-Wamono; Annalise E Zemlin; Brian W Allwood
Journal:  Ann Clin Biochem       Date:  2020-11-20       Impact factor: 2.057

View more
  3 in total

1.  A Patient-Ready Wearable Transcutaneous CO2 Sensor.

Authors:  Juan Pedro Cascales; Xiaolei Li; Emmanuel Roussakis; Conor L Evans
Journal:  Biosensors (Basel)       Date:  2022-05-13

2.  Transcutaneous carbon dioxide monitoring in ALS: Assessment of hypoventilation heats up.

Authors:  Jason Ackrivo; Andrew Geronimo
Journal:  Muscle Nerve       Date:  2022-02-14       Impact factor: 3.217

3.  What do masks mask? A study on transdermal CO2 monitoring.

Authors:  Kenta Iitani; Joel Tyson; Samyukta Rao; Sai Sathish Ramamurthy; Xudong Ge; Govind Rao
Journal:  Med Eng Phys       Date:  2021-10-27       Impact factor: 2.242

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.