Literature DB >> 32513249

Prehospital pulse oximetry: a red flag for early detection of silent hypoxemia in COVID-19 patients.

Romain Jouffroy1, Daniel Jost2, Bertrand Prunet1.   

Abstract

Entities:  

Mesh:

Year:  2020        PMID: 32513249      PMCID: PMC7278215          DOI: 10.1186/s13054-020-03036-9

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.
The COVID-19 pandemic, which has been expanding since the first cases in Asia in late 2019, may result in acute respiratory failure (ARF) with severe hypoxemia [1-3]. In prehospital settings, the paucity of clinical respiratory signs has made assessing the severity of some COVID-19 patients challenging. Indeed, even though hypoxic ARF generally leads to an increase in respiratory rate (RR) [4], in some COVID-19 patients, a persistent normal RR was inconsistent with the severity of hypoxia. Based on retrospective data, we aimed to describe the discrepancy between prehospital initial RR (RRi) and initial SpO2 (Spo2i; i.e., before oxygen supplementation, FiO2 = 21%) in COVID-19 patients suffering from ARF. We retrospectively examined consecutive COVID-19 patients suffering from ARF who were treated by the Paris Fire Brigade’s basic life-support (BLS) teams in the prehospital setting. Data were provided from primary home care providers. Based on a previous study [5], we used the SpO2i/RRi ratio as an estimator of the discrepancy insofar as a low numerator is associated with hypoxia, whereas a high denominator is typically associated with respiratory failure. After having measured the SpO2i/RRi values in COVID-19 patients, we compared them to those of non-COVID-19 patients (i.e., patients with other causes of ARF treated by the BLS teams over the previous 3 years in the same period). Continuous data were described as median (interquartile range) and were compared by applying the Kruskal-Wallis test. The French Society of Anaesthesia and Intensive Care approved the trial protocol on April 7, 2020 (IRB 00010254-2020-055). The study examined 1201 patients who experienced COVID-19 between March 13 and 29, 2020. The median SpO2i/RRi value was significantly higher than that of patients treated in the previous 3 years (5 [4, 5] in 2020 versus 3.4 [2.4–4.5] in 2019, 3.3[2.2–4.4] in 2018, and 3.5[2.5–4.6] in 2017, p < 0.001, Fig. 1).
Fig. 1

Scatter plot representing the initial SPO2 (SPO2i) and initial respiration rate (RRi) values for each patient, for COVID-19 (March 2020) and non-COVID-19 patients from the previous 3 years. The horizontal and vertical lines indicate the threshold values of SPO2 95% and respiration rate, 20 breaths per minute, respectively. We used the Kruskal-Wallis test to compare the median SPO2i/RRi value, between the period “13th to March 29, 2020,” and the three previous years (p value < 0.001). RRi, initial respiratory rate; SpO2i, initial pulse oximetry value; N, number of patients included

Scatter plot representing the initial SPO2 (SPO2i) and initial respiration rate (RRi) values for each patient, for COVID-19 (March 2020) and non-COVID-19 patients from the previous 3 years. The horizontal and vertical lines indicate the threshold values of SPO2 95% and respiration rate, 20 breaths per minute, respectively. We used the Kruskal-Wallis test to compare the median SPO2i/RRi value, between the period “13th to March 29, 2020,” and the three previous years (p value < 0.001). RRi, initial respiratory rate; SpO2i, initial pulse oximetry value; N, number of patients included In summary, this retrospective study based on prehospital first responder data highlighted a relatively higher discrepancy between SpO2i and RRi in COVID-19 ARF patients, in comparison with previous non-COVID-19 ARF patients. Without a systematic SpO2i measurement, a normal breathing rate could mask profound hypoxia and make severity assessment in COVID-19 patients all the more difficult in an out-of-hospital setting. Despite differences in worldwide prehospital emergency medical services, pulse oximetry is an accessible tool that prehospital healthcare providers can easily use. In conclusion, prehospital pulse oximetry might be used as a red flag for early detection of “silent hypoxemia” in COVID-19 patients. The prehospital SpO2i/RRi ratio needs further investigation because it might help to identify non-clinically obvious ARFs.
  39 in total

1.  Description and Early Results of the Kaiser Permanente Southern California COVID-19 Home Monitoring Program.

Authors:  Dan Ngoc Huynh; Alyssa Millan; Earl Quijada; Deborah John; Shariq Khan; Tadashi Funahashi
Journal:  Perm J       Date:  2021-07-28

2.  Development of Low-Cost and Portable Pulse Oximeter Device with Improved Accuracy and Accessibility.

Authors:  Hundessa Daba Nemomssa; Hakkins Raj
Journal:  Med Devices (Auckl)       Date:  2022-05-05

Review 3.  Evidence based management guidelines in dentistry during the COVID-19 pandemic - a review of the literature.

Authors:  Kanamarlapudi Venkata Saikiran; Putta Sai Sahiti; Somisetty Venkata Mahalakshmi Mounika; Sainath Reddy Elicherla; Raichurkar Hemanth Kumar; Gonegandla Giriraj Sandeep
Journal:  Med Pharm Rep       Date:  2021-10-30

4.  Silent Hypoxia in Coronavirus disease-2019: Is it more dangerous? -A retrospective cohort study.

Authors:  Prashant Sirohiya; Arunmozhimaran Elavarasi; Hari Krishna Raju Sagiraju; Madhusmita Baruah; Nishkarsh Gupta; Rohit Kumar Garg; Saurav Sekhar Paul; Brajesh Kumar Ratre; Ram Singh; Balbir Kumar; Saurabh Vig; Anuja Pandit; Abhishek Kumar; Rakesh Garg; Ved Prakash Meena; Saurabh Mittal; Saurabh Pahuja; Nupur Das; Tanima Dwivedi; Ritu Gupta; Sunil Kumar; Manisha Pandey; Abhinav Mishra; Karanvir Singh Matharoo; Anant Mohan; Randeep Guleria; Sushma Bhatnagar
Journal:  Lung India       Date:  2022 May-Jun

5.  Wearable Transcutaneous CO2 Monitor Based on Miniaturized Nondispersive Infrared Sensor.

Authors:  Vishal Varun Tipparaju; Sabrina Jimena Mora; Jingjing Yu; Francis Tsow; Xiaojun Xian
Journal:  IEEE Sens J       Date:  2021-05-19       Impact factor: 4.325

6.  Population-level impact of a pulse oximetry remote monitoring programme on mortality and healthcare utilisation in the people with COVID-19 in England: a national analysis using a stepped wedge design.

Authors:  Thomas Beaney; Jonathan Clarke; Ahmed Alboksmaty; Kelsey Flott; Aidan Fowler; Jonathan Benger; Paul P Aylin; Sarah Elkin; Ana Luisa Neves; Ara Darzi
Journal:  Emerg Med J       Date:  2022-04-13       Impact factor: 3.814

7.  Tribute to Dr. Takuo Aoyagi, inventor of pulse oximetry.

Authors:  Katsuyuki Miyasaka; Kirk Shelley; Shosuke Takahashi; Hironami Kubota; Kazumasa Ito; Ikuto Yoshiya; Akio Yamanishi; Jeffrey B Cooper; David J Steward; Hiroshi Nishida; Joe Kiani; Hirokazu Ogino; Yasuhiko Sata; Robert J Kopotic; Kitty Jenkin; Alex Hannenberg; Atul Gawande
Journal:  J Anesth       Date:  2021-08-02       Impact factor: 2.078

8.  Pre-symptomatic detection of COVID-19 from smartwatch data.

Authors:  Tejaswini Mishra; Meng Wang; Ahmed A Metwally; Gireesh K Bogu; Andrew W Brooks; Amir Bahmani; Arash Alavi; Alessandra Celli; Emily Higgs; Orit Dagan-Rosenfeld; Bethany Fay; Susan Kirkpatrick; Ryan Kellogg; Michelle Gibson; Tao Wang; Erika M Hunting; Petra Mamic; Ariel B Ganz; Benjamin Rolnik; Xiao Li; Michael P Snyder
Journal:  Nat Biomed Eng       Date:  2020-11-18       Impact factor: 29.234

9.  Considerations for target oxygen saturation in COVID-19 patients: are we under-shooting?

Authors:  Niraj Shenoy; Rebecca Luchtel; Perminder Gulani
Journal:  BMC Med       Date:  2020-08-19       Impact factor: 8.775

10.  Clinical and epidemiological features discriminating confirmed COVID-19 patients from SARS-CoV-2 negative patients at screening centres in Madagascar.

Authors:  Mihaja Raberahona; Rado Rakotomalala; Etienne Rakotomijoro; Tokinandrianina Rahaingoalidera; Christophe Elody Andry; Natacha Mamilaza; Lova Dany Ella Razafindrabekoto; Efrasie Rafanomezantsoa; Volatiana Andriananja; Radonirina Lazasoa Andrianasolo; Soloniaina Hélio Razafimahefa; Rivonirina Andy Rakotoarivelo; Mamy Jean de Dieu Randria
Journal:  Int J Infect Dis       Date:  2020-11-17       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.