| Literature DB >> 34717715 |
Cheng-Chieh Huang1,2, Kuan-Chih Chen1, Zih-Yang Lin1, Yu-Hsuan Chou1, Wen-Liang Chen2, Tsung-Han Lee1,2, Kun-Te Lin1, Pei-You Hsieh1,2, Cheng Hsu Chen1,2, Chu-Chung Chou1,3,4,5, Yan-Ren Lin6,7,8,9.
Abstract
OBJECTIVE: Experimental studies of head-up positioning (HUP) during cardiopulmonary resuscitation (CPR) have had some degree of conflicting published results. The current study aim was to analyze and reconcile those discrepancies in order to better clarify the effects of HUP CPR compared to conventional supine (SUP) CPR.Entities:
Keywords: Cardiopulmonary resuscitation; Cerebral perfusion pressure; Head-up position
Mesh:
Year: 2021 PMID: 34717715 PMCID: PMC8557496 DOI: 10.1186/s13054-021-03797-x
Source DB: PubMed Journal: Crit Care ISSN: 1364-8535 Impact factor: 9.097
Fig. 1PRISMA flow diagram
The characteristics of the included studies
| Study, year | Design | Species | Sample size | No-flow time | CPR method | Head-up angle | CPR time |
|---|---|---|---|---|---|---|---|
| Debaty et al. [ | Non-RCT | Female Yorkshire farm pigs | 22 | 6 min | LUCAS 2.0 + ITD CPR | − 30°–50°a | 22 min |
| Ryu et al. [ | RCT | Female Yorkshire farm pigs | 30 | 8 min | CCPR, ACD + ITD CPRc | 0° and 30° | 22 min |
| Kim et al. [ | Non-RCT | Female pigs | 12 | 6 min | LUCAS 2.0 + ITD CPR | − 60°–60°a | 18 min |
| Moore et al. [ | RCT | Female Yorkshire farm pigs | 18 | 8 min | ACD + ITD CPRc | 0° and 30° | 20 min |
| Putzer et al. [ | RCT | Domestic pigs | 20 | 8 min | LUCAS 2.0 CPR | 0° and 30° | 20 min |
| Moore et al. [ | Non-RCT | Female Yorkshire farm pigs, pig cadaver, human cadaver | 27b | 6 min | CCPR, ACD + ITD CPRcd | 0° and 30° | 26 min |
| Park et al. [ | RCT | Female Yorkshire farm pigs | 18 | 15 min | LUCAS 2.0 + ITD CPR | 0° and 30°a | 6 min |
RCT randomized controlled trial, ACD active compression–decompression, CPR cardiopulmonary resuscitation, ITD impedance threshold device, CCPR conventional cardiopulmonary resuscitation
aA negative number represents the Trendelenburg position, and a positive number represents the reverse-Trendelenburg position
bIncludes 9 human cadavers
cUse of a customized animal ACR-CPR machine
dUse of a manual ACD pump + ITD (ResQPump) on human cadavers
Quality assessments according to the ARRIVE guidelines 2.0
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | Quality score | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Debaty 2015 | + | + | − | + | + | + | + | + | + | + | + | + | + | + | − | − | + | − | + | + | + | 17 |
| Ryu 2016 | + | + | − | + | − | + | + | + | + | + | + | + | + | + | − | + | + | + | + | − | + | 17 |
| Kim 2017 | + | + | − | + | + | + | + | − | + | + | + | + | + | + | − | − | + | + | + | + | + | 17 |
| Moore 2017 | + | + | − | + | + | + | + | + | + | + | + | + | + | + | − | − | + | + | + | + | + | 18 |
| Putzer 2018 | + | + | − | + | − | + | + | − | + | + | + | + | + | + | − | + | + | + | + | + | + | 17 |
| Moore 2018 | + | − | − | − | − | + | + | + | + | + | + | + | + | + | − | + | + | + | + | − | + | 15 |
| Park 2019 | + | + | − | + | − | + | + | + | + | + | + | + | + | + | − | + | + | + | + | − | + | 17 |
Quality items: (1) study design; (2) sample size; (3) inclusion and exclusion criteria; (4) randomization; (5) blinding; (6) outcome measures; (7) statistical methods; (8) experimental animals; (9) experimental procedures; (10) results; (11) abstract; (12) background; (13) objectives; (14) ethical statement; (15) housing and husbandry; (16) animal care and monitoring; (17) interpretation/scientific implications; (18) generalizability/translation; (19) protocol registration; (20) data access; and (21) declaration of interests
Fig. 2Cerebral perfusion pressure
Fig. 3Intracranial pressure and mean arterial pressure
Fig. 4Coronary perfusion pressure and ROSC rate