| Literature DB >> 34674967 |
Virgilio Galvis1, Luis C Escaf2, Luis J Escaf3, Alejandro Tello1, Lisi D Rodríguez4, Ruth Lapid-Gortzak5, Néstor I Carreño1, Rubén D Berrospi1, Camilo A Niño1, Andreas Viberg6, Paul A Camacho1.
Abstract
PURPOSE: To assess visual results (including the Lapid-Kushlin defocus coefficient), and satisfaction, following the implantation of PanOptix® a trifocal intraocular lens.Entities:
Keywords: Cataract surgery; Multifocal intraocular lens; Trifocal intraocular lens
Mesh:
Year: 2021 PMID: 34674967 PMCID: PMC9237585 DOI: 10.1016/j.optom.2021.05.002
Source DB: PubMed Journal: J Optom ISSN: 1989-1342
Final binocular visual results.
| Mean± SD (LogMAR) | Mean (Snellen) | Range (LogMAR) | Range (Snellen) | |
|---|---|---|---|---|
| Binocular UDVA | 0.04 ± 0.06 | 20/22 | 0.18 to 0.0 | 20/30 to 20/20 |
| Binocular UIVA | 0.07 ± 0.08 | 20/24 | 0.30 to 0.0 | 20/40 to 20/20 |
| Binocular UNVA | 0.05 ± 0.08 | 20/22 | 0.18 to 0.0 | 20/30 to 20/20 |
SD: Standard deviation
UDVA: Uncorrected distance visual acuity
UIVA: Uncorrected intermediate visual acuity
UNVA: Uncorrected near visual acuity
At 65 cm
At 40 cm
Final postoperative refraction.
| WITHIN (D) | CUMULATIVE NUMBER OF EYES (CUMULATIVE %) | |
|---|---|---|
| SPHERICAL EQUIVALENT | ± 0.25 | 91 (70 %) |
| ± 0.50 | 116 (89.2%) | |
| ± 0.75 | 127 (97.7%) | |
| ± 1.00 | 128 (98.4%) | |
| ± 1.25 | 130 (100%) | |
| REFRACTIVE CYLINDER | ± 0.25 | 81 (62.3 %) |
| ± 0.50 | 106 (81.5%) | |
| ± 0.75 | 123 (94.6%) | |
| ± 1.00 | 128 (98.4%) | |
| ± 1.50 | 130 (100%) | |
| DEFOCUS EQUIVALENT | ± 0.25 | 71 (54.6 %) |
| ± 0.50 | 102 (78.5%) | |
| ± 0.75 | 116 (89.2%) | |
| ± 1.00 | 123 (94.6%) | |
| ± 1.50 | 130 (100%) |
Defocus equivalent = |Spherical equivalent|+ (|Refractive Cylinder|/2)
Fig. 1Binocular defocus curve, with subjects corrected for distance. Viewing distances indicated for each negative lens placed were calculated after adjusting the real negative vergence of each lens, accounting for the 4 meters chart distance (i.e. adding -0.25 D of negative vergence to the power of the lens presented in front of a patient's eye).
Fig. 2Contrast sensitivity test results (Optec 6500P) compared with the normality for the age group (according to Hohberger et al).
CATQUEST-9SF questionnaire results.
| No difficulty (Score 1) | Some difficulties (Score 2) | Great difficulties (Score 3) | Very great difficulties (score 4) | |
|---|---|---|---|---|
| Do you consider that your current vision causes you in some way difficulties in your daily life? | 62 (93,9%) | 4 (6,1%) | 0 (0%) | 0 (0%) |
| Very satisfied (Score 1) | Fairly satisfied (Score 2) | Rather dissatisfied | Very dissatisfied | |
| Are you satisfied or dissatisfied with your current vision? | 56 (84.8%) | 10 (15.2%) | 0 (0%) | 0 (0%) |
| Do you have difficulties when performing the following activities because of your vision? | No difficulty | Some difficulties (score 2) | Great difficulties | Very great difficulties |
| Read the texts of the newspapers | 58 (87.9%) | 8 (12.1%) | 0 (0%) | 0 (0%) |
| Recognize the faces of the people who known | 61 (92.4%) | 5 (7.6%) | 0 (0%) | 0 (0%) |
| See prices of things when will you buy | 57 (86.4%) | 9 (13.6%) | 0 (0%) | 0 (0%) |
| Walking for irregular surfaces. | 64 (97%) | 2 (3%) | 0 (0%) | 0 (0%) |
| Make jobs manuals | 64 (97%) | 2 (3%) | 0 (0%) | 0 (0%) |
| Read subtitles on television | 63(95.5%) | 3(4.5%) | 0 (0%) | 0 (0%) |
| When you perform some activity / hobby in which you are interested | 62 (93.9%) | 4 (6.1%) | 0 (0%) | 0 (0%) |