Kjell Gunnar Gundersen1, Bjørn Gjerdrum1, Richard Potvin2.
Abstract
Purpose: To evaluate the visual function of patients with a history of prior laser vision correction and cataract surgery with implantation of a monofocal primary IOL after subsequent implantation of a secondary sulcus trifocal intraocular lens (IOL). Setting: One clinical practice in Haugesund, Norway. Design: Prospective, single arm, non-interventional unmasked study.Entities:
Keywords: 1stQ AddOn®; LASIK surgery; intraocular lens; post-LASIK cataract surgery; secondary IOL; sulcus IOL; trifocal IOL
Year: 2022 PMID: 35837490 PMCID: PMC9275502 DOI: 10.2147/OPTH.S372925
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Figure 1The AddOn® trifocal sulcus lens (courtesy 1stQ GmbH, used with permission).
Demographics and LASIK/Cataract History (25 Eyes of 13 Subjects)
| n | Average | SD | Minimum | Maximum | ||
|---|---|---|---|---|---|---|
| Prior to LASIK | Sphere | 21 | −3.42 | 1.70 | −6.50 | −1.25 |
| Cylinder | 10 | −0.60 | 0.45 | −1.35 | −0.25 | |
| Spherical equivalent | 21 | −3.57 | 1.67 | −6.50 | −1.50 | |
| Primary IOL | Sphere | 25 | 20.6 | 2.1 | 16.5 | 24.5 |
| Cylinder | 16 | 1.22 | 0.26 | 1.00 | 1.50 |
Abbreviations: SD, standard deviation; LASIK, laser in situ keratomileusis.
Refractive Data Before and After Trifocal Sulcus IOL Implantation
| Mean | SD | Minimum | Maximum | p value | ||
|---|---|---|---|---|---|---|
| Refractive cylinder (D) | Before | −0.21 | 0.25 | −0.75 | 0.00 | 0.02 |
| After | −0.40 | 0.35 | −1.25 | 0.00 | ||
| Spherical equivalent (D) | Before | 0.13 | 0.24 | −0.25 | 0.75 | 0.01 |
| After | −0.11 | 0.34 | −1.25 | 0.38 |
Abbreviations: D, diopter; SD, standard deviation.
Figure 2Monocular visual acuity by correction and distance.
Cumulative Monocular Visual Acuity Results by Distance and Correction (n = 25)
| Cumulative Visual Acuity | ||||||||
|---|---|---|---|---|---|---|---|---|
| Snellen | 20/16 | 20/20 | 20/25 | 20/32 | 20/40 | 20/63 | 20/80 | |
| logMAR | −0.1 | 0 | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | |
| Uncorrected | Distance (4 m) | 12% | 36% | 76% | 88% | 92% | 96% | 100% |
| Intermediate (60 cm) | 0% | 0% | 24% | 60% | 72% | 96% | 96% | |
| Near (40 cm) | 0% | 32% | 60% | 80% | 92% | 100% | 100% | |
| Distance corrected | Distance (4 m) | 32% | 76% | 92% | 100% | 100% | 100% | 100% |
| Intermediate (60 cm) | 4% | 8% | 40% | 68% | 72% | 100% | 100% | |
| Near (40 cm) | 0% | 44% | 84% | 92% | 96% | 100% | 100% | |
Abbreviation: logMAR, log of the minimum angle of resolution.
Binocular Visual Acuity Results (n = 13)
| Status | Distance | logMAR Acuity (Lower is Better) | |||
|---|---|---|---|---|---|
| Mean | SD | Minimum | Maximum | ||
| Uncorrected | Distance (4 m) | −0.05 | 0.11 | −0.2 | 0.1 |
| Intermediate (60 cm) | 0.09 | 0.10 | −0.1 | 0.26 | |
| Near (40 cm) | 0.04 | 0.09 | −0.08 | 0.22 | |
| Distance Corrected | Distance (4 m) | −0.08 | 0.10 | −0.22 | 0.1 |
| Intermediate (60 cm) | 0.10 | 0.15 | −0.18 | 0.32 | |
| Near (40 cm) | 0.02 | 0.09 | −0.12 | 0.2 | |
Abbreviations: SD, standard deviation; logMAR, log of the minimum angle of resolution.
Figure 3Monocular defocus curve.