Binbing Wang1, Weibiao Hu2, Guoping Shan1, Xiaoxian Xu3.
Abstract
BACKGROUND: Image-guided adaptive brachytherapy shows the ability to deliver high doses to tumors while sparing normal tissues. However, interfraction dose delivery introduces uncertainties to high dose estimation, which relates to normal tissue toxicity. The purpose of this study was to investigate the high-dose regions of two applicator approaches in brachytherapy.Entities:
Keywords: Accumulative dose; Deformable registration; Interstitial brachytherapy; Intracavitary brachytherapy
Mesh:
Year: 2021 PMID: 34663336 PMCID: PMC8524953 DOI: 10.1186/s12938-021-00942-z
Source DB: PubMed Journal: Biomed Eng Online ISSN: 1475-925X Impact factor: 2.819
Deformable image registration outcomes of two different applicators in this study
| Bladder | Rectum | |||||
|---|---|---|---|---|---|---|
| ICBT ( | ISBT ( | ICBT ( | ISBT ( | |||
| DiffVol | 0.72–1.53 | 0.64–1.67 | 0.24 | 0.43–1.51 | 0.67–1.31 | 0.19 |
| Dice | 0.97 (0.87–0.99) | 0.98 (0.81–1) | 0.17 | 0.95 (0.8–0.98) | 0.97 (0.87–1) | 0.01 |
| ≥ 0.9, | 48 (96) | 45 (95.7) | 45 (90) | 45 (95.7) | ||
| 0.42 ± 0.40 | 0.28 ± 0.25 | < 0.01 | 0.75 ± 0.46 | 0.31 ± 0.32 | < 0.01 | |
| 4.43 ± 1.69 | 5.06 ± 2.44 | < 0.01 | 4.26 ± 1.52 | 5.90 ± 2.15 | < 0.01 | |
| D2cc (DIR/GEC) | 0.99 (0.94–1.05) | 0.96 (0.91–1.07) | < 0.01 | 1.00 (0.96–1.08) | 0.94 (0.91–1.06) | < 0.01 |
| Overestimated, | 5 (10) | 6 (12.8) | 6 (8) | 1 (10.6) | ||
Fig. 1A patient with accumulative dose estimation of ICBT. The purple contour represents the bladder and the green contour represents the rectum. The high-dose area is distributed around the applicator. The 2 cc volume is distributed near the cervix of each fraction is shown in a–d. The 2 cc volume after deformation is distributed in either the posterior wall of the bladder or the anterior wall of the rectum as shown in e and f
Fig. 2A patient with accumulative dose estimation of ISBT approach. The purple contour represents the bladder and the green contour represents the rectum. The D2cc region of each fraction is shown in a–d. The 2 cc volume distribution is different between fractions. D2cc region is distributed dispersed in deformed image shown in e and f
Fig. 3The prototype of 3D-printed ICBT applicator
Fig. 4The deformation process of multi-fraction dose accumulation