Literature DB >> 34662206

Diagnostic accuracy and complication rate of image-guided percutaneous transthoracic needle lung biopsy for subsolid pulmonary nodules: a systematic review and meta-analysis.

Junghoon Kim1, Choong Guen Chee2, Jungheum Cho1, Youngjune Kim3, Min A Yoon2.   

Abstract

OBJECTIVES: To determine the diagnostic accuracy and complication rate of percutaneous transthoracic needle biopsy (PTNB) for subsolid pulmonary nodules and sources of heterogeneity among reported results.
METHODS: We searched PubMed, EMBASE, and Cochrane libraries (until November 7, 2020) for studies measuring the diagnostic accuracy of PTNB for subsolid pulmonary nodules. Pooled sensitivity and specificity of PTNB were calculated using a bivariate random-effects model. Bivariate meta-regression analyses were performed to identify sources of heterogeneity. Pooled overall and major complication rates were calculated.
RESULTS: We included 744 biopsies from 685 patients (12 studies). The pooled sensitivity and specificity of PTNB for subsolid nodules were 90% (95% confidence interval [CI]: 85-94%) and 99% (95% CI: 92-100%), respectively. Mean age above 65 years was the only covariate significantly associated with higher sensitivity (93% vs  85%, p = 0.04). Core needle biopsy showed marginally higher sensitivity than fine-needle aspiration (93% vs  83%, p = 0.07). Pooled overall and major complication rate of PTNB were 43% (95% CI: 25-62%) and 0.1% (95% CI: 0-0.4%), respectively. Major complication rate was not different between fine-needle aspiration and core needle biopsy groups (p = 0.25).
CONCLUSION: PTNB had acceptable performance and a low major complication rate in diagnosing subsolid pulmonary nodules. The only significant source of heterogeneity in reported sensitivities was a mean age above 65 years. ADVANCES IN KNOWLEDGE: This is the first meta-analysis attempting to systemically determine the cause of heterogeneity in the diagnostic accuracy and complication rate of PTNB for subsolid pulmonary nodules.

Entities:  

Mesh:

Year:  2021        PMID: 34662206      PMCID: PMC8553211          DOI: 10.1259/bjr.20210065

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  45 in total

1.  Localized pure ground-glass opacity on high-resolution CT: histologic characteristics.

Authors:  Ryu Nakajima; Tomoyuki Yokose; Ryutaro Kakinuma; Kanji Nagai; Yutaka Nishiwaki; Atsushi Ochiai
Journal:  J Comput Assist Tomogr       Date:  2002 May-Jun       Impact factor: 1.826

2.  CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions: diagnostic yield in 83 lesions.

Authors:  Daisaku Inoue; Hideo Gobara; Takao Hiraki; Hidefumi Mimura; Katsuya Kato; Kentaro Shibamoto; Tatsuhiko Iishi; Yusuke Matsui; Shinichi Toyooka; Susumu Kanazawa
Journal:  Eur J Radiol       Date:  2010-12-28       Impact factor: 3.528

3.  Malignant versus benign nodules at CT screening for lung cancer: comparison of thin-section CT findings.

Authors:  Feng Li; Shusuke Sone; Hiroyuki Abe; Heber Macmahon; Kunio Doi
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

4.  Diagnostic performance of CT-guided percutaneous transthoracic core needle biopsy using low tube voltage (100 kVp): comparison with conventional tube voltage (120 kVp).

Authors:  Han Na Lee; Sang Min Lee; Jooae Choe; Sang Min Lee; Eun Jin Chae; Kyung-Hyun Do; Joon Beom Seo
Journal:  Acta Radiol       Date:  2017-07-10       Impact factor: 1.990

5.  CT Screening for Lung Cancer: Nonsolid Nodules in Baseline and Annual Repeat Rounds.

Authors:  David F Yankelevitz; Rowena Yip; James P Smith; Mingzhu Liang; Ying Liu; Dong Ming Xu; Mary M Salvatore; Andrea S Wolf; Raja M Flores; Claudia I Henschke
Journal:  Radiology       Date:  2015-06-23       Impact factor: 11.105

6.  CT-guided fine-needle aspiration and core needle biopsies of pulmonary lesions: a single-center experience with 750 biopsies in Japan.

Authors:  Jumpei Takeshita; Katsuhiro Masago; Ryoji Kato; Akito Hata; Reiko Kaji; Shiro Fujita; Nobuyuki Katakami
Journal:  AJR Am J Roentgenol       Date:  2015-01       Impact factor: 3.959

7.  Diagnostic accuracy of CT fluoroscopy-guided needle aspiration biopsy of ground-glass opacity pulmonary lesions.

Authors:  Jin Hur; Hye-Jeong Lee; Ji Eun Nam; Young Jin Kim; Tae Hoon Kim; Kyu Ok Choe; Byoung Wook Choi
Journal:  AJR Am J Roentgenol       Date:  2009-03       Impact factor: 3.959

8.  C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤ 20 mm) lung nodules: diagnostic accuracy and complications in 161 patients.

Authors:  Jin Woo Choi; Chang Min Park; Jin Mo Goo; Yang-Kyun Park; Wonmo Sung; Hyun-Ju Lee; Sang Min Lee; Ji Young Ko; Mi-Suk Shim
Journal:  AJR Am J Roentgenol       Date:  2012-09       Impact factor: 3.959

9.  QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies.

Authors:  Penny F Whiting; Anne W S Rutjes; Marie E Westwood; Susan Mallett; Jonathan J Deeks; Johannes B Reitsma; Mariska M G Leeflang; Jonathan A C Sterne; Patrick M M Bossuyt
Journal:  Ann Intern Med       Date:  2011-10-18       Impact factor: 25.391

10.  Determining malignancy in CT guided fine needle aspirate biopsy of subsolid lung nodules: Is core biopsy necessary?

Authors:  Nantaka Kiranantawat; Shaunagh McDermott; Milena Petranovic; Mari Mino-Kenudson; Ashok Muniappan; Amita Sharma; Jo-Anne O Shepard; Subba R Digumarthy
Journal:  Eur J Radiol Open       Date:  2019-05-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.