Literature DB >> 28691525

Diagnostic performance of CT-guided percutaneous transthoracic core needle biopsy using low tube voltage (100 kVp): comparison with conventional tube voltage (120 kVp).

Han Na Lee1, Sang Min Lee1, Jooae Choe1, Sang Min Lee1, Eun Jin Chae1, Kyung-Hyun Do1, Joon Beom Seo1.   

Abstract

Background Computed tomography (CT)-guided percutaneous transthoracic core needle biopsy (PTNB) is typically performed at 120 kVp tube voltage. However, there is no study that has demonstrated diagnostic performance including ground-glass nodules and radiation dose reduction at lower tube voltage in large population. Purpose To retrospectively compare the diagnostic performance and radiation dose between 100 kVp and 120 kVp during CT-guided PTNB. Material and Methods This study included 393 PTNBs performed in 385 patients (Group I; 120 kVp) from March 2011 to September 2011 and 1368 PTNBs performed in 1318 patients (Group II; 100 kVp) from October 2011 to December 2013. The patients underwent CT-guided PTNB with the coaxial technique. Diagnostic performance, complication rate, and radiation dose were compared between two groups. Results Technical success was achieved in 391 of 393 PTNBs (99.5%) in Group I and in 1344 of 1368 PTNBs (98.2%) in Group II ( P = 0.09). The diagnostic accuracies for pulmonary lesions were not significantly different between two groups (97.1% [362/373] versus 96.2% [1202/1249], P = 0.458). Complication rate showed no significant differences between two groups in terms of pneumothorax (19.7% [77/391] versus 19.4% [261/1344], P = 0.904) and hemoptysis (2.3% [9/391] versus 3.2% [43/1344], P = 0.360). Among patients who developed pneumothorax, three patients (3.9%, 3/77) in Group I and eight patients (3.1%, 8/261) in Group II required treatment with drainage catheter. Nobody needed further treatment for hemoptysis in the two groups. The mean radiation dose was 1.5 ± 1.9 mSv in Group I and 0.7 ± 0.3 mSv in Group II ( P < 0.001). Conclusion The 100-kVp protocol for CT-guided PTNB showed significant benefit of radiation dose reduction while maintaining high diagnostic accuracy and safety.

Entities:  

Keywords:  Needle biopsy; computed tomography (CT); lung; radiation exposure

Mesh:

Year:  2017        PMID: 28691525     DOI: 10.1177/0284185117719589

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  6 in total

1.  Diagnostic accuracy and complication rate of image-guided percutaneous transthoracic needle lung biopsy for subsolid pulmonary nodules: a systematic review and meta-analysis.

Authors:  Junghoon Kim; Choong Guen Chee; Jungheum Cho; Youngjune Kim; Min A Yoon
Journal:  Br J Radiol       Date:  2021-10-18       Impact factor: 3.039

2.  Low-dose CT with tin filter combined with iterative metal artefact reduction for guiding lung biopsy.

Authors:  Jing Zhang; Meiling Liu; Daihong Liu; Xiaoqin Li; Meng Lin; Yong Tan; Yuesheng Luo; Xiangfei Zeng; Hong Yu; Hesong Shen; Xiaoxia Wang; Leilei Liu; Yuchuan Tan; Jiuquan Zhang
Journal:  Quant Imaging Med Surg       Date:  2022-02

Review 3.  2020 Clinical Practice Guideline for Percutaneous Transthoracic Needle Biopsy of Pulmonary Lesions: A Consensus Statement and Recommendations of the Korean Society of Thoracic Radiology.

Authors:  Soon Ho Yoon; Sang Min Lee; Chul Hwan Park; Jong Hyuk Lee; Hyungjin Kim; Kum Ju Chae; Kwang Nam Jin; Kyung Hee Lee; Jung Im Kim; Jung Hee Hong; Eui Jin Hwang; Heekyung Kim; Young Joo Suh; Samina Park; Young Sik Park; Dong Wan Kim; Miyoung Choi; Chang Min Park
Journal:  Korean J Radiol       Date:  2020-11-19       Impact factor: 3.500

4.  Computed tomography-guided cutting needle biopsy for lung nodules: A comparative study between low-dose and standard dose protocols.

Authors:  Hui-Mei Zhang; Xiao-Bing Huo; Hua-Long Wang; Xiao Zhang; Yu-Fei Fu
Journal:  Medicine (Baltimore)       Date:  2021-01-22       Impact factor: 1.889

5.  Value of low-dose and optimized-length computed tomography (CT) scan in CT-guided percutaneous transthoracic needle biopsy of pulmonary nodules.

Authors:  Hui Yuan; Da Li; Yan Zhang; Xiaozhen Xie; Lujun Shen
Journal:  J Interv Med       Date:  2021-05-21

6.  Computed tomography-guided core needle biopsy for lung nodules: low-dose versus standard-dose protocols.

Authors:  Yi-Yang Huang; Hong Cheng; Guang-Chao Li
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2021-02-03       Impact factor: 1.195

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.