Literature DB >> 34619722

Are Serum Ion Levels Elevated in Pediatric Patients With Metal Implants?

Smitha E Mathew1, Yong Xie1,2, Leila Bagheri1, Liam E Claton1, Lin Chu1,3, Amr Badreldin1, Matthew P Abdel1, Andre J van Wijnen1,4, Geoffrey F Haft5, Todd A Milbrandt1, A Noelle Larson1.   

Abstract

BACKGROUND: Previous studies report elevated serum titanium (Ti) levels in children with spinal implants. To provide additional data on this topic, we sought to assess serum ion levels at multiple timepoints in pediatric patients with growing spine devices, spinal fusion instrumentation, and extremity implants placed for fracture treatment. We hypothesized that serum Ti, cobalt (Co), and chromium (Cr) levels would be elevated in pediatric patients with growing spine devices compared with patients with extremity implants.
METHODS: Pediatric patients undergoing any primary spine implant placement, those with spine implant revision or removal surgery and patients with other appendicular implant removal had serum Ti, Co, and Cr ion levels drawn at the time of surgery. Fifty-one patients (12 growing spine devices, 13 fusions, and 26 extremity implants) had one set of labs, 31 of whom had labs drawn both preoperatively and postoperatively. Biopsies obtained from tissue specimens at the time of implant revision were analyzed histologically for the presence of metal debris and macrophage activity.
RESULTS: Patients with growing spine implants had elevated serum Ti (3.3 vs. 1.9 ng/mL, P=0.01) and Cr levels (1.2 vs. 0.27 ng/mL, P=0.01) in comparison to patients with fusion rods or extremity implants. With respect to patients with extremity implants, patients with growing spine devices had elevated serum Ti (3.3 vs. 0.98 ng/mL, P=0.013), Co (0.63 vs. 0.26 ng/mL, P=0.017), and Cr levels (1.18 vs. 0.26 ng/mL, P=0.005). On matched pairs analysis, patients who had labs drawn before and after spine implantation had significant increase in serum Ti levels (0.57 vs. 3.3 ng/mL, P=0.02). Histology of tissue biopsies adjacent to growing spine implants showed presence of metal debris and increased macrophage activity compared with patients with extremity implants.
CONCLUSION: Serum Ti, Co, and Cr levels are elevated in children with spinal implants compared with those with extremity implants, particularly in those with growing spine devices. However, the clinical significance of these findings remains to be determined. LEVEL OF EVIDENCE: Level II-prospective comparative study.
Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 34619722      PMCID: PMC8828674          DOI: 10.1097/BPO.0000000000001957

Source DB:  PubMed          Journal:  J Pediatr Orthop        ISSN: 0271-6798            Impact factor:   2.324


  35 in total

1.  Aluminium and lead toxicity revisited: mechanisms explaining the particular sensitivity of the brain to oxidative damage.

Authors:  H M Bolt; J G Hengstler
Journal:  Arch Toxicol       Date:  2008-11       Impact factor: 5.153

2.  Which is better Stainless Steel or Titanium alloy?

Authors:  Sibel Akyol; Hakan Bozkus; Suzan Adin Cinar; Mehmet Murat Hanci
Journal:  Turk Neurosurg       Date:  2017-06-14       Impact factor: 1.003

3.  Elevated Serum Titanium Levels in Children With Early Onset Scoliosis Treated With Growth-friendly Instrumentation.

Authors:  Ying Li; Chelsea K Graham; Christopher Robbins; Michelle S Caird; Frances A Farley
Journal:  J Pediatr Orthop       Date:  2020-07       Impact factor: 2.324

Review 4.  Aluminum and Alzheimer's disease: after a century of controversy, is there a plausible link?

Authors:  Lucija Tomljenovic
Journal:  J Alzheimers Dis       Date:  2011       Impact factor: 4.472

5.  Metal debris from titanium spinal implants.

Authors:  J C Wang; W D Yu; H S Sandhu; F Betts; S Bhuta; R B Delamarter
Journal:  Spine (Phila Pa 1976)       Date:  1999-05-01       Impact factor: 3.468

6.  Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study.

Authors:  H Ziaee; J Daniel; A K Datta; S Blunt; D J W McMinn
Journal:  J Bone Joint Surg Br       Date:  2007-03

7.  Do retained pediatric implants impact later total hip arthroplasty?

Authors:  Jessica Woodcock; A Noelle Larson; Tad M Mabry; Anthony A Stans
Journal:  J Pediatr Orthop       Date:  2013 Apr-May       Impact factor: 2.324

8.  Spinal implant debris-induced osteolysis.

Authors:  Nadim J Hallab; Brian W Cunningham; Joshua J Jacobs
Journal:  Spine (Phila Pa 1976)       Date:  2003-10-15       Impact factor: 3.468

9.  Metal concentrations in the serum and hair of patients with titanium alloy spinal implants.

Authors:  Yuichi Kasai; Ryu Iida; Atsumasa Uchida
Journal:  Spine (Phila Pa 1976)       Date:  2003-06-15       Impact factor: 3.468

10.  Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*.

Authors:  Brett R Levine; Andrew R Hsu; Anastasia K Skipor; Nadim J Hallab; Wayne G Paprosky; Jorge O Galante; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-03-20       Impact factor: 5.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.