Literature DB >> 17356138

Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study.

H Ziaee1, J Daniel, A K Datta, S Blunt, D J W McMinn.   

Abstract

Metal-on-metal bearings are being increasingly used in young patients. The potential adverse effects of systemic metal ion elevation are the subject of ongoing investigation. The purpose of this study was to investigate whether cobalt and chromium ions cross the placenta of pregnant women with a metal-on-metal hip resurfacing and reach the developing fetus. Whole blood levels were estimated using high-resolution inductively-coupled plasma mass spectrometry. Our findings showed that cobalt and chromium are able to cross the placenta in the study patients with metal-on-metal hip resurfacings and in control subjects without any metal implants. In the study group the mean concentrations of cobalt and chromium in the maternal blood were 1.39 microg/l (0.55 to 2.55) and 1.28 microg/l (0.52 to 2.39), respectively. The mean umbilical cord blood concentrations of cobalt and chromium were comparatively lower, at 0.839 microg/l (0.42 to 1.75) and 0.378 microg/l (0.14 to 1.03), respectively, and this difference was significant with respect to chromium (p < 0.05). In the control group, the mean concentrations of cobalt and chromium in the maternal blood were 0.341 microg/l (0.18 to 0.54) and 0.199 microg/l (0.12 to 0.33), and in the umbilical cord blood they were 0.336 microg/l (0.17 to 0.5) and 0.194 microg/l (0.11 to 0.56), respectively. The differences between the maternal and umbilical cord blood levels in the controls were marginal, and not statistically significant (p > 0.05). The mean cord blood level of cobalt in the study patients was significantly greater than that in the control group (p < 0.01). Although the mean umbilical cord blood chromium level was nearly twice as high in the study patients (0.378 microg/l) as in the controls (0.1934 microg/l), this difference was not statistically significant. (p > 0.05) The transplacental transfer rate was in excess of 95% in the controls for both metals, but only 29% for chromium and 60% for cobalt in study patients, suggesting that the placenta exerts a modulatory effect on the rate of metal ion transfer.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17356138     DOI: 10.1302/0301-620X.89B3.18520

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  27 in total

1.  Perioperative management of patients with connective tissue disease.

Authors:  Susan M Goodman; Mark P Figgie; C Ronald Mackenzie
Journal:  HSS J       Date:  2010-08-17

2.  Hip resurfacing in patients who have osteonecrosis and are 25 years or under.

Authors:  Siraj A Sayeed; Aaron J Johnson; D Alex Stroh; Thomas P Gross; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup.

Authors:  Christian P Delaunay; Sophie Putman; Benjamin Puliéro; Matthieu Bégin; Henri Migaud; François Bonnomet
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

4.  Metal-on-metal: history, state of the art (2010).

Authors:  Philippe Triclot
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

5.  The Hard on Hard Bearings in THA - Current concepts.

Authors:  P Gopinathan
Journal:  J Orthop       Date:  2014-09-19

6.  [Complications of metal-on-metal tribological pairing].

Authors:  M Stiehler; F Zobel; F Hannemann; J Schmitt; J Lützner; S Kirschner; K-P Günther; A Hartmann
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

7.  Alumina-on-alumina THA performed in patients younger than 30 years: a 10-year minimum followup study.

Authors:  Hyeong Jo Yoon; Jeong Joon Yoo; Kang Sup Yoon; Kyung-Hoi Koo; Hee Joong Kim
Journal:  Clin Orthop Relat Res       Date:  2012-07-24       Impact factor: 4.176

8.  Polyethylene in total hip arthroplasty: half a century in the limelight.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo
Journal:  J Orthop Traumatol       Date:  2010-05-27

Review 9.  Is patient selection important for hip resurfacing?

Authors:  Ryan M Nunley; Craig J Della Valle; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2008-10-22       Impact factor: 4.176

10.  Total hip replacement in the congenitally dislocated hip using the Paavilainen technique: 19 hips followed for 1.5-10 years.

Authors:  Bjørn Thorup; Inger Mechlenburg; Kjeld Søballe
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.