Literature DB >> 34593686

Optimizing Parameters for Using the Parallel Auditory Brainstem Response to Quickly Estimate Hearing Thresholds.

Melissa J Polonenko1,2, Ross K Maddox1,2,3.   

Abstract

OBJECTIVES: Timely assessments are critical to providing early intervention and better hearing and spoken language outcomes for children with hearing loss. To facilitate faster diagnostic hearing assessments in infants, the authors developed the parallel auditory brainstem response (pABR), which presents randomly timed trains of tone pips at five frequencies to each ear simultaneously. The pABR yields high-quality waveforms that are similar to the standard, single-frequency serial ABR but in a fraction of the recording time. While well-documented for standard ABRs, it is yet unknown how presentation rate and level interact to affect responses collected in parallel. Furthermore, the stimuli are yet to be calibrated to perceptual thresholds. Therefore, this study aimed to determine the optimal range of parameters for the pABR and to establish the normative stimulus level correction values for the ABR stimuli.
DESIGN: Two experiments were completed, each with a group of 20 adults (18-35 years old) with normal-hearing thresholds (≤20 dB HL) from 250 to 8000 Hz. First, pABR electroencephalographic (EEG) responses were recorded for six stimulation rates and two intensities. The changes in component wave V amplitude and latency were analyzed, as well as the time required for all responses to reach a criterion signal-to-noise ratio of 0 dB. Second, behavioral thresholds were measured for pure tones and for the pABR stimuli at each rate to determine the correction factors that relate the stimulus level in dB peSPL to perceptual thresholds in dB nHL.
RESULTS: The pABR showed some adaptation with increased stimulation rate. A wide range of rates yielded robust responses in under 15 minutes, but 40 Hz was the optimal singular presentation rate. Extending the analysis window to include later components of the response offered further time-saving advantages for the temporally broader responses to low-frequency tone pips. The perceptual thresholds to pABR stimuli changed subtly with rate, giving a relatively similar set of correction factors to convert the level of the pABR stimuli from dB peSPL to dB nHL.
CONCLUSIONS: The optimal stimulation rate for the pABR is 40 Hz but using multiple rates may prove useful. Perceptual thresholds that subtly change across rate allow for a testing paradigm that easily transitions between rates, which may be useful for quickly estimating thresholds for different configurations of hearing loss. These optimized parameters facilitate expediency and effectiveness of the pABR to estimate hearing thresholds in a clinical setting.
Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2022        PMID: 34593686      PMCID: PMC8881303          DOI: 10.1097/AUD.0000000000001128

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.562


  40 in total

1.  Auditory brainstem responses to chirps delivered by different insert earphones.

Authors:  Claus Elberling; Sinnet G B Kristensen; Manuel Don
Journal:  J Acoust Soc Am       Date:  2012-03       Impact factor: 1.840

2.  Effects of stimulus rate on the feline brain-stem auditory evoked response during development. I. Peak latencies.

Authors:  R Burkard; J McGee; E J Walsh
Journal:  J Acoust Soc Am       Date:  1996-08       Impact factor: 1.840

3.  A preliminary investigation of the deconvolution of auditory evoked potentials using a session jittering paradigm.

Authors:  Tao Wang; Changan Zhan; Gang Yan; Jorge Bohórquez; Özcan Özdamar
Journal:  J Neural Eng       Date:  2013-03-26       Impact factor: 5.379

4.  Calibration/Standardization of Short-Duration Stimuli.

Authors:  Einar Laukli; Robert Burkard
Journal:  Semin Hear       Date:  2015-02

5.  Clinical application of dichotic multiple-stimulus auditory steady-state responses in high-risk newborns and young children.

Authors:  Heleen Luts; Christian Desloovere; Jan Wouters
Journal:  Audiol Neurootol       Date:  2005-10-10       Impact factor: 1.854

6.  Brain stem auditory evoked responses: studies of waveform variations in 50 normal human subjects.

Authors:  K H Chiappa; K J Gladstone; R R Young
Journal:  Arch Neurol       Date:  1979-02

7.  Effect of click rate on the latency of auditory brain stem responses in humans.

Authors:  M Don; A R Allen; A Starr
Journal:  Ann Otol Rhinol Laryngol       Date:  1977 Mar-Apr       Impact factor: 1.547

8.  Exposing distinct subcortical components of the auditory brainstem response evoked by continuous naturalistic speech.

Authors:  Melissa J Polonenko; Ross K Maddox
Journal:  Elife       Date:  2021-02-17       Impact factor: 8.140

9.  Cochlear neuropathy and the coding of supra-threshold sound.

Authors:  Hari M Bharadwaj; Sarah Verhulst; Luke Shaheen; M Charles Liberman; Barbara G Shinn-Cunningham
Journal:  Front Syst Neurosci       Date:  2014-02-21

Review 10.  Auditory Brainstem Responses in Tinnitus: A Review of Who, How, and What?

Authors:  Victoria Milloy; Philippe Fournier; Daniel Benoit; Arnaud Noreña; Amineh Koravand
Journal:  Front Aging Neurosci       Date:  2017-07-21       Impact factor: 5.750

View more
  1 in total

1.  Comparison of Auditory Steady-State Responses With Conventional Audiometry in Older Adults.

Authors:  Hadeel Y Tarawneh; Hamid R Sohrabi; Wilhelmina H A M Mulders; Ralph N Martins; Dona M P Jayakody
Journal:  Front Neurol       Date:  2022-07-04       Impact factor: 4.086

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.