| Literature DB >> 34561548 |
Aleksandra Wlaź1, Agnieszka Kustra2, Agnieszka Rozegnał-Madej2, Tomasz Żarnowski2.
Abstract
To compare refractive outcomes after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes and to investigate the accuracy of 3 intraocular lens (IOL) calculation formulas in these eyes. In this prospective comparative study 42 eyes (PEX group) and 38 eyes (control group) of 80 patients were included. The follow-up was 3 months. The refractive prediction error (RPE), mean absolute error (MAE), median absolute error (MedAE) and the percentages of eyes within ± 0.25 D, ± 0.5 D, ± 1.0 D and ± 2.0 D of prediction error were calculated. Three IOL calculation formulas (SRK/T, Barrett Universal II and Hill-RBF) were evaluated. PEX produced statistically significantly higher mean absolute errors and lower percentages of eyes within ± 0.5 D than control eyes in all investigated IOL calculation formulas. There were no statistically significant differences in the median absolute errors between the 3 formulas in either PEX or control eyes. Refractive outcomes after cataract surgery are statistically significantly worse in PEX than in control eyes. All three IOL calculation formulas produced similar results in both PEX and control eyes.Trial registration: ClinicalTrials.gov registration number NCT04783909.Entities:
Mesh:
Year: 2021 PMID: 34561548 PMCID: PMC8463556 DOI: 10.1038/s41598-021-98675-5
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Baseline characteristics.
| Characteristic | Mean ± SD | ||
|---|---|---|---|
| PEX | Control | ||
| Age (y) | 77.26 ± 6.97 | 74.21 ± 9.90 | 0.198a |
| Sex (male/female) | 15/27 | 20/18 | 0.176b |
| Right/left eye | 21/21 | 23/15 | 0.376b |
| AxL (mm) | 23.38 ± 0.75 | 23.48 ± 1.01 | 0.784a |
| ACD (mm) | 2.98 ± 0.48 | 3.19 ± 0.36 | 0.012a |
| K (D) | 43.95 ± 1.65 | 43.56 ± 1.53 | 0.525a |
| IOL power (D) | 21.13 ± 1.61 | 21.42 ± 2.53 | 0.242a |
| LOCS score (NS) | 2.64 ± 0.73 | 2.60 ± 0.72 | 0.811a |
AxL: axial length; ACD: anterior chamber depth; K: keratometry; IOL: intraocular lens; y: year; mm: millimeter; D: diopter; LOCS: Lens Opacities Classification System III; NS: nuclear sclerosis.
aMann–Whitney U test; bFisher’s exact test.
Refractive prediction error, mean absolute error and median absolute error produced by each formula in PEX and control groups without adjusting mean RPE to zero.
| SRK/T | Barrett Universal II | Hill-RBF | ||
|---|---|---|---|---|
| RPE ± SD, D (range) | 0.321 ± 0.644 (1.440, + 1.710) | 0.322 ± 0.641 (− 1.490, + 1.970) | 0.283 ± 0.643 (− 1.500, + 1.970) | |
| MAE ± SD, D | 0.589 ± 0.406 | 0.569 ± 0.431, | 0.566 ± 0.420 | |
| MedAE, D | 0.505 | 0.505 | 0.410 | 0.570 |
| RPE ± SD, D (range) | 0.303 ± 0.381 (− 0.480, + 1.355) | 0.203 ± 0.371 (− 0.580, + 1.355) | 0.188 ± 0.379 (− 0.570, + 1.225) | |
| MAE ± SD, D | 0.379 ± 0.303 | 0.320 ± 0.273 | 0.312 ± 0.283 | |
| MedAE, D | 0.333 | 0.315 | 0.185 | 0.001 |
PEX: pseudoexfoliation syndrome; RPE: refractive prediction error; SD: standard deviation; D: diopter; MAE: mean absolute error; MedAE: median absolute error.
Refractive prediction error, mean absolute error and median absolute error produced by each formula in PEX and control groups after adjusting mean RPE to zero.
| SRK/T | Barrett Universal II | Hill-RBF | ||
|---|---|---|---|---|
| RPE ± SD, D (range) | 0.000 ± 0.644 (− 1.761, + 1.389) | 0.000 ± 0.641 (− 1.812, + 1.648) | 0.000 ± 0.643 (− 1.783, + 1.687) | |
| MAE ± SD, D | 0.498 ± 0.401 | 0.479 ± 0.420, | 0.479 ± 0.420 | |
| MedAE, D | 0.460 | 0.385 | 0.400 | 0.636 |
| RPE ± SD, D (range) | 0.000 ± 0.381 (− 0.783, + 1.052) | 0.000 ± 0.371 (− 0.783, + 1.152) | 0.000 ± 0.379 (− 0.758, + 1.038) | |
| MAE ± SD, D | 0.288 ± 0.244 | 0.286 ± 0.232 | 0.292 ± 0.237 | |
| MedAE, D | 0.213 | 0.219 | 0.243 | 0.442 |
PEX: pseudoexfoliation syndrome; RPE: refractive prediction error; SD: standard deviation; D: diopter; MAE: mean absolute error; MedAE: median absolute error.
Figure 1Box plot presentation of the absolute error (after adjusting the mean numerical refractive prediction error to zero) of IOL calculation formulas in PEX and control groups. There were statistically significant differences between PEX and control groups in all three formulas. Median values (horizontal lines), 25/75 percentiles (boxes), 5/95 percentiles (whiskers) and outliers (dots). *p < 0.05 PEX versus Control group (Mann–Whitney U test); IOL = intraocular lens; PEX = pseudoexfoliation syndrome.
Percentage of eyes with refractive prediction errors within ± 0.25 D, ± 0.5 D, ± 1.0 D and ± 2.0 D after adjusting the mean numerical refractive prediction errors to zero (Fisher’s exact test).
| Prediction error within | SRK/T | Barrett Universal II | Hill-RBF | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Control | PEX | p | Control | PEX | p | Control | PEX | p | |
| ± 0.25 D | 21 (55.26) | 16 (38.10) | 0.178 | 22 (57.89) | 14 (33.33) | 0.042* | 20 (52.63) | 14 (33.33) | 0.113 |
| ± 0.5 D | 31 (81.58) | 24 (57.14) | 0.029* | 32 (84.21) | 26 (61.90) | 0.044* | 31 (81.58) | 26 (61.91) | 0.044* |
| ± 1.0 D | 37 (97.37) | 38 (90.48) | 0.362 | 37 (97.37) | 39 (92.86) | 0.617 | 37 (97.37) | 39 (92.86) | 0.617 |
| ± 2.0 D | 38 (100.00) | 42 (100.00) | – | 38 (100.00) | 42 (100.00) | – | 38 (100.00) | 42 (100.0) | – |
PEX: pseudoexfoliation syndrome; D: diopter; * p < 0.05.
Figure 2Histogram comparing the percentage of cases within a given diopter range of refractive prediction error for three IOL power calculation formulas in PEX and control group. No significant differences were found among the three formulas using Cochran Q test (all p > 0.05) in either PEX or control eyes. IOL = intraocular lens; PEX = pseudoexfoliation syndrome.
Figure 3Scatterplots showing correlations between preoperative ACD and MAE in SRK/T (a), Barrett Universal II (b) and Hill-RBF (c) formulas. No significant association between preoperative ACD and MAE was found in any of evaluated IOL calculation formulas in either PEX or control group. Pearson’s correlation analysis revealed trend of negative correlation between preoperative ACD and MAE in SRK/T and Hill-RBF formulas in PEX eyes.