Literature DB >> 8512486

The Lens Opacities Classification System III. The Longitudinal Study of Cataract Study Group.

L T Chylack1, J K Wolfe, D M Singer, M C Leske, M A Bullimore, I L Bailey, J Friend, D McCarthy, S Y Wu.   

Abstract

OBJECTIVE: To develop the Lens Opacities Classification System III (LOCS III) to overcome the limitations inherent in lens classification using LOCS II. These limitations include unequal intervals between standards, only one standard for color grading, use of integer grading, and wide 95% tolerance limits. DESIGN AND
RESULTS: The LOCS III contains an expanded set of standards that were selected from the Longitudinal Study of Cataract slide library at the Center for Clinical Cataract Research, Boston, Mass. It consists of six slit-lamp images for grading nuclear color (NC) and nuclear opalescence (NO), five retroillumination images for grading cortical cataract (C), and five retroillumination images for grading posterior subcapsular (P) cataract. Cataract severity is graded on a decimal scale, and the standards have regularly spaced intervals on a decimal scale. The 95% tolerance limits are reduced from 2.0 for each class with LOCS II to 0.7 for nuclear opalescence, 0.7 for nuclear color, 0.5 for cortical cataract, and 1.0 for posterior subcapsular cataract with the LOCS III, with excellent interobserver agreement.
CONCLUSION: The LOCS III is an improved LOCS system for grading slit-lamp and retroillumination images of age-related cataract.

Entities:  

Mesh:

Year:  1993        PMID: 8512486     DOI: 10.1001/archopht.1993.01090060119035

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  663 in total

1.  Grading nuclear cataract: reproducibility and validity of a new method.

Authors:  N F Hall; P Lempert; R P Shier; R Zakir; D Phillips
Journal:  Br J Ophthalmol       Date:  1999-10       Impact factor: 4.638

2.  Population based assessment of uveitis in an urban population in southern India.

Authors:  L Dandona; R Dandona; R K John; C A McCarty; G N Rao
Journal:  Br J Ophthalmol       Date:  2000-07       Impact factor: 4.638

Review 3.  Prevention strategies for age related cataract: present limitations and future possibilities.

Authors:  N G Congdon
Journal:  Br J Ophthalmol       Date:  2001-05       Impact factor: 4.638

Review 4.  Aging and vision.

Authors:  Cynthia Owsley
Journal:  Vision Res       Date:  2010-10-23       Impact factor: 1.886

5.  Eccentricity and measurement variability and repeatability with the retinal thickness analyser.

Authors:  E D Gilmore; C Hudson
Journal:  Br J Ophthalmol       Date:  2004-01       Impact factor: 4.638

6.  Education, socioeconomic status, and ocular dimensions in Chinese adults: the Tanjong Pagar Survey.

Authors:  T Y Wong; P J Foster; G J Johnson; S K L Seah
Journal:  Br J Ophthalmol       Date:  2002-09       Impact factor: 4.638

7.  Complication rate and risk factors for intraoperative complications in resident-performed phacoemulsification surgery.

Authors:  Andrea Briszi; Philipp Prahs; Jost Hillenkamp; Horst Helbig; Wolfgang Herrmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-04-11       Impact factor: 3.117

8.  Correlation of a scanning laser derived oedema index and visual function following grid laser treatment for diabetic macular oedema.

Authors:  C Hudson; J G Flanagan; G S Turner; H C Chen; L B Young; D McLeod
Journal:  Br J Ophthalmol       Date:  2003-04       Impact factor: 4.638

9.  Normative best-corrected values of the visual image quality metric VSX as a function of age and pupil size.

Authors:  Gareth D Hastings; Jason D Marsack; Larry N Thibos; Raymond A Applegate
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2018-05-01       Impact factor: 2.129

10.  Catatrac: a novel red light-emitting diode device for screening cataracts in the developing world.

Authors:  M Q Rahman; A P Rotchford; K Ramaesh
Journal:  Eye (Lond)       Date:  2012-10-26       Impact factor: 3.775

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.