| Literature DB >> 34515925 |
Motoo Nakagawa1, Taku Naiki2, Aya Naiki-Ito3, Yoshiyuki Ozawa4, Masashi Shimohira4, Masahiro Ohnishi4, Yuta Shibamoto4.
Abstract
PURPOSE: Detecting bladder cancer (BC) in routine CT images is important but is sometimes difficult when cancer is small. We evaluated the ability of 40-keV advanced monoenergetic images to depict BC.Entities:
Keywords: Advanced virtual monoenergetic image; Bladder cancer; Dual energy CT
Mesh:
Year: 2021 PMID: 34515925 PMCID: PMC8803668 DOI: 10.1007/s11604-021-01195-5
Source DB: PubMed Journal: Jpn J Radiol ISSN: 1867-1071 Impact factor: 2.374
Pathological T (pT) stages
| pT stage | |
|---|---|
| Tis | 5 |
| Ta | 26 |
| T1 | 12 |
| T2a | 2 |
| T2b | 1 |
| T3a | 3 |
| T3b | 2 |
| T4a | 1 |
| T4b | 0 |
| Total | 52 |
Fig. 1Stage pT1 invasive urothelial carcinoma in a 61-year-old man. Transverse CT images (a 40 keV, b 120 kVp, c excretory phase 120 kVp) show a mass (arrows) on the posterior bladder wall. The mass is more clearly depicted on 40-keV than on 120-kVp images (40 keV, grade 2; 120 kVp, grade 1; excretory phase, grade 3)
Image quality of virtual-120-kVp, 40-keV, and excretory-phase images for bladder cancer
| 120 kVp | 40 keV | Excretory phase | 40 + E | 120 + E | |
|---|---|---|---|---|---|
| Grade 3 | 21 | 27 | 26 | 32 | 29 |
| Grade 2 | 7 | 13 | 6 | 10 | 6 |
| Grade 1 | 13 | 2 | 6 | 1 | 7 |
| Grade 0 | 11 | 10 | 14 | 9 | 10 |
| Average grade (± SD) | 1.7 ± 1.2 | 2.1 ± 1.2 | 1.8 ± 1.3 | 2.3 ± 1.1 | 2.0 ± 1.2 |
40 + E: combination of 40-keV and excretory-phase images
120 + E: combination of virtual-120-kVp and excretory-phase images
SD standard deviation
Fig. 2Stage pT1 invasive urothelial carcinoma with divergent differentiation in a 66-year-old man. Sagittal CT images (a 40 keV, b 120 kVp, c excretory phase 120 kVp) show a mass (arrows) on the dome of the bladder. The mass is not depicted on the excretory phase image because the anterior part of the inside of the bladder is not enhanced. The mass is more clearly depicted on 40-keV than on 120-kVp images (40 keV, grade 3; 120 kVp, grade 2; excretory phase, grade 0)
Objective evaluation of virtual-120-kVp and 40-keV images
| Virtual 120 kVp | 40 keV | |||
|---|---|---|---|---|
| Bladder cancer | Bladder wall | Bladder cancer | Bladder wall | |
| CT number (H.U.) | 71.5 ± 163 | 60.1 ± 9.4 | 167 ± 54 | 86.4 ± 24 |
| SD | 8.0 ± 2.5 | 6.8 ± 4.9 | 26.8 ± 8.2 | 17.7 ± 8.1 |
| ROI (mm2) | 17.3 ± 13.2 | 5.7 ± 4.2 | 17.3 ± 13.2 | 5.7 ± 4.2 |
| CNR | 1.38 | 6.77 | ||
CT computed tomography, H.U. Hounsfield unit, SD standard deviation, ROI region of interest, CNR contrast-to-noise ratio