Literature DB >> 34406821

Metal artifact reduction using common dental materials.

Nicole V Hinchy1, Nina K Anderson2, Mina Mahdian1.   

Abstract

OBJECTIVES: To determine the effect of different dental lab materials on cone beam computed tomography (CBCT) metal artifact at different resolutions.
METHODS: A total of seven common dental lab materials were molded to a dental sextant of four extracted, restored teeth. In addition to base alone (control), each material was scanned using the Carestream 9600 CBCT unit at three resolutions - 0.3 mm, 0.15 mm, and 0.075 mm - at manufacturer established exposure parameters. A single, representative axial view of each trial was evaluated for metal artifact both quantitatively by histogram analysis and qualitatively by profile plot analysis in ImageJ.
RESULTS: No statistically significant differences between the control and the dental materials were found; however, post-hoc tests showed significance between Blu-mousse® and polyvinyl siloxane with dental materials and control, predominantly in lower resolutions.
CONCLUSIONS: The current study provides initial evidence on the influence of dental materials have on CBCT metal artifact as described by beam hardening, photon starvation, scatter, and noise, especially at lower resolutions. Blu-Mousse® and polyvinyl siloxane reduced the perceived beam hardening and photon starvation artifact the greatest, relative to other materials, at all three resolutions and lower resolutions, respectively.

Entities:  

Keywords:  Artifacts; Cone-Beam Computed Tomography; Dental Materials

Mesh:

Substances:

Year:  2021        PMID: 34406821      PMCID: PMC8802694          DOI: 10.1259/dmfr.20210302

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  25 in total

1.  Fabrication of bolus compensators used in the treatment of irregular tissue surfaces in radiation therapy.

Authors:  C F Driscoll; M A Taylor; J S Ostrowski
Journal:  J Prosthet Dent       Date:  1992-03       Impact factor: 3.426

2.  Experimental wax mixtures for dental use.

Authors:  E Kotsiomiti; J F McCabe
Journal:  J Oral Rehabil       Date:  1997-07       Impact factor: 3.837

3.  Evaluation and Reduction of Artifacts Generated by 4 Different Root-end Filling Materials by Using Multiple Cone-beam Computed Tomography Imaging Settings.

Authors:  Dilek Helvacioglu-Yigit; Husniye Demirturk Kocasarac; Boulos Bechara; Marcel Noujeim
Journal:  J Endod       Date:  2015-12-19       Impact factor: 4.171

4.  Use of maxillofacial laboratory materials to construct a tissue-equivalent head phantom with removable titanium implantable devices for use in verification of the dose of intensity-modulated radiotherapy.

Authors:  K Morris
Journal:  Br J Oral Maxillofac Surg       Date:  2017-02-27       Impact factor: 1.651

5.  Comparative Evaluation of Tensile Bond Strength between Silicon Soft Liners and Processed Denture Base Resin Conditioned by Three Modes of Surface Treatment: An Invitro Study.

Authors:  Hemchand Surapaneni; Padma Ariga; R Haribabu; Y Ravi Shankar; V H C Kumar; Sirisha Attili
Journal:  J Indian Prosthodont Soc       Date:  2013-01-06

6.  A CT metal artifact reduction algorithm based on sinogram surgery.

Authors:  Soomin Jeon; Chang-Ock Lee
Journal:  J Xray Sci Technol       Date:  2018       Impact factor: 1.535

7.  Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy.

Authors:  Marian Axente; Ajay Paidi; Rie Von Eyben; Chuan Zeng; Ali Bani-Hashemi; Andreas Krauss; Dimitre Hristov
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

8.  The effects of metal artifact reduction on the retrieval of attenuation values.

Authors:  Christian Ziemann; Maik Stille; Florian Cremers; Dirk Rades; Thorsten M Buzug
Journal:  J Appl Clin Med Phys       Date:  2016-12-05       Impact factor: 2.102

9.  Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials.

Authors:  Martina Gerlane de Oliveira Pinto; Saulo Leonardo Sousa Melo; Yuri Wanderley Cavalcanti; Elisa Diniz de Lima; Patrícia Meira Bento; Daniela Pita de Melo
Journal:  Imaging Sci Dent       Date:  2020-06-18

10.  Effect of dental restorations and prostheses on radiotherapy dose distribution: a Monte Carlo study.

Authors:  David W H Chin; Nathaniel Treister; Bernard Friedland; Robert A Cormack; Roy B Tishler; G Mike Makrigiorgos; Laurence E Court
Journal:  J Appl Clin Med Phys       Date:  2009-02-03       Impact factor: 2.102

View more