Literature DB >> 26711863

Evaluation and Reduction of Artifacts Generated by 4 Different Root-end Filling Materials by Using Multiple Cone-beam Computed Tomography Imaging Settings.

Dilek Helvacioglu-Yigit1, Husniye Demirturk Kocasarac2, Boulos Bechara3, Marcel Noujeim4.   

Abstract

INTRODUCTION: After endodontic surgery, radiographic assessment is the method of choice to monitor bone defect healing. Cone-beam computed tomography scans are useful to check and identify the reasons of failure of surgical intervention or confirm healing; however, the artifact generated by some root-end filling material might compromise this task. The objective of the study was to compare the amount of artifacts generated by 4 root-end filling materials and to test multiple exposure settings used with these materials, when the effective dose generated by each protocol was taken into consideration.
METHODS: Twenty central incisors were endodontically treated with retrograde obturation by using amalgam, Biodentine, MTA, and Super-EBA (5 of each). They were placed in a skull with soft tissue simulation and scanned by using the Planmeca Promax Max with different kilovolt peaks (kVp): 66, 76, 84, and 96 with and without the use of metal artifact reduction (MAR) algorithm and with low, normal, and high resolution and high definition. The Dose Area Product was registered, and the effective dose was calculated.
RESULTS: Amalgam generated the highest amount of artifacts, whereas MAR and low resolution created fewer artifacts than other settings. The artifacts were also reduced with 96 kVp. The effective dose calculated with low resolution was remarkably lower than other resolutions.
CONCLUSIONS: When used as root-end filling material, Biodentine, MTA, and Super-EBA generated fewer artifacts than amalgam. The use of 96 kVp with MAR and low resolution also reduced artifacts on the image and at the same time generated the lowest effective dose.
Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Artifact; CBCT; beam hardening; root-end filling

Mesh:

Substances:

Year:  2015        PMID: 26711863     DOI: 10.1016/j.joen.2015.11.002

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  13 in total

1.  Are metal artefact reduction algorithms effective to correct cone beam CT artefacts arising from the exomass?

Authors:  Amanda Pelegrin Candemil; Benjamin Salmon; Deborah Queiroz Freitas; Glaucia Maria Bovi Ambrosano; Francisco Haiter-Neto; Matheus Lima Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2019-01-28       Impact factor: 2.419

2.  Metal artifact reduction using common dental materials.

Authors:  Nicole V Hinchy; Nina K Anderson; Mina Mahdian
Journal:  Dentomaxillofac Radiol       Date:  2021-08-18       Impact factor: 2.419

Review 3.  Biodentine™ material characteristics and clinical applications: a 3 year literature review and update.

Authors:  S Rajasekharan; L C Martens; R G E C Cauwels; R P Anthonappa
Journal:  Eur Arch Paediatr Dent       Date:  2018-01-25

4.  CBCT image artefacts generated by implants located inside the field of view or in the exomass.

Authors:  Husniye Demirturk Kocasarac; Lisa J Koenig; Gulbahar Ustaoglu; Matheus Lima Oliveira; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2021-07-29       Impact factor: 2.419

5.  Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.

Authors:  Aline Pf Caetano; Thiago O Sousa; Mariana R Oliveira; Karine Evanglista; Juliano M Bueno; Maria Ag Silva
Journal:  Dentomaxillofac Radiol       Date:  2020-12-01       Impact factor: 2.419

Review 6.  Diagnosis of cracked teeth using cone-beam computed tomography: literature review and clinical experience.

Authors:  Antian Gao; Dantong Cao; Zitong Lin
Journal:  Dentomaxillofac Radiol       Date:  2021-04-29       Impact factor: 3.525

7.  Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars.

Authors:  Clarissa Teles Rodrigues; Reinhilde Jacobs; Karla Faria Vasconcelos; Paul Lambrechts; Izabel Regina Fisher Rubira-Bullen; Hugo Gaêta-Araujo; Christiano Oliveira-Santos; Marco Antonio Hungaro Duarte
Journal:  Dentomaxillofac Radiol       Date:  2021-01-05       Impact factor: 3.525

8.  Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials.

Authors:  Martina Gerlane de Oliveira Pinto; Saulo Leonardo Sousa Melo; Yuri Wanderley Cavalcanti; Elisa Diniz de Lima; Patrícia Meira Bento; Daniela Pita de Melo
Journal:  Imaging Sci Dent       Date:  2020-06-18

9.  Influence of CBCT metal artifact reduction on vertical radicular fracture detection.

Authors:  Mariana Rodrigues Oliveira; Thiago Oliveira Sousa; Aline Ferreira Caetano; Rogério Ribeiro de Paiva; José Valladares-Neto; Fernanda Paula Yamamoto-Silva; Maria Alves Garcia Silva
Journal:  Imaging Sci Dent       Date:  2021-01-29

10.  Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters.

Authors:  Katharina Alves Rabelo; Yuri Wanderley Cavalcanti; Martina Gerlane de Oliveira Pinto; Saulo Leonardo Sousa Melo; Paulo Sérgio Flores Campos; Luciana Soares de Andrade Freitas Oliveira; Daniela Pita de Melo
Journal:  Imaging Sci Dent       Date:  2017-09-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.