A CT metal artifact reduction algorithm based on sinogram surgery.

Soomin Jeon1, Chang-Ock Lee1.   

Abstract

BACKGROUND: Streak artifacts in computed tomography (CT) images caused by metallic objects limit the wider use of CT imaging technologies. There have been various attempts to improve CT images containing streak artifacts; however, most of them generate additional artifacts or do not completely eradicate existing artifacts.
OBJECTIVE: In this paper, we propose a novel algorithm which reduces streak artifacts in CT images.
METHODS: Using CT numbers reconstructed from a given sinogram, we extract the metal part M and the surrounding area C with similar CT numbers. By filling in the area C ∪ M with the evaluated average CT number of C, we obtain a modified CT image. Using forward projection of the modified CT image, we generate a sinogram containing information about the anatomical structure. We undertake sinogram surgery to remove the metallic effects from the sinogram, after which we repeat the procedure.
RESULTS: We perform numerical experiments using various simulated phantoms and patient images. For a quantitative analysis, we use the relative l∞ error and the relative l2 error. In simulated phantom experiments, all l∞ errors and l2 errors approach 10% and 1% of the initial errors, respectively. Moreover, for the patient image simulations, all l∞ errors are decreased by a factor of 20 while the l2 errors are decreased less than 5%. We observe that the proposed algorithm effectively reduces the metal artifacts.
CONCLUSIONS: In this paper, we propose a metal artifact reduction algorithm based on sinogram surgery to reduce metal artifacts without additional artifacts. We also provide empirical convergence of our algorithm.

Entities:  

Keywords:  Computed tomography (CT); iterative algorithm; metal artifact reduction; sinogram surgery

Mesh:

Substances:

Year:  2018        PMID: 29562579     DOI: 10.3233/XST-17336

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  2 in total

1.  Metal artifact reduction using common dental materials.

Authors:  Nicole V Hinchy; Nina K Anderson; Mina Mahdian
Journal:  Dentomaxillofac Radiol       Date:  2021-08-18       Impact factor: 2.419

2.  Completion of Metal-Damaged Traces Based on Deep Learning in Sinogram Domain for Metal Artifacts Reduction in CT Images.

Authors:  Linlin Zhu; Yu Han; Xiaoqi Xi; Lei Li; Bin Yan
Journal:  Sensors (Basel)       Date:  2021-12-07       Impact factor: 3.576