A Probabilistic Approach for Contact Stability and Contact Safety Analysis of Robotic Intracardiac Catheter.

Ran Hao1, M Cenk Çavuşoğlu1.   

Abstract

The disturbances caused by the blood flow and tissue surface motions are major concerns during the motion planning of an intracardiac robotic catheter. Maintaining a stable and safe contact on the desired ablation point is essential for achieving effective lesions during the ablation procedure. In this paper, a probabilistic formulation of the contact stability and the contact safety for intravascular cardiac catheters under the blood flow and surface motion disturbances is presented. Probabilistic contact stability and contact safety metrics, employing a sample-based representation of the blood flow velocity distribution and the heart motion trajectory, are introduced. Finally, the contact stability and safety for an magnetic resonance imaging-actuated robotic catheter under main pulmonary artery blood flow disturbances and left ventricle surface motion disturbances are analyzed in simulation as example scenarios.
Copyright © 2021 by ASME.

Entities:  

Year:  2021        PMID: 34334808      PMCID: PMC8299815          DOI: 10.1115/1.4050692

Source DB:  PubMed          Journal:  J Dyn Syst Meas Control        ISSN: 0022-0434            Impact factor:   1.640


  14 in total

1.  Design of a Magnetic Resonance Imaging Guided Magnetically Actuated Steerable Catheter.

Authors:  Taoming Liu; Nate Lombard Poirot; Tipakorn Greigarn; M Cenk Çavuşoğlu
Journal:  J Med Device       Date:  2017-05-03       Impact factor: 0.582

2.  Contact Stability Analysis of Magnetically-Actuated Robotic Catheter Under Surface Motion.

Authors:  Ran Hao; Tipakorn Greigarn; M Cenk Çavuşoğlu
Journal:  IEEE Int Conf Robot Autom       Date:  2020-09-15

3.  Jacobian-Based Task-Space Motion Planning for MRI-Actuated Continuum Robots.

Authors:  Tipakorn Greigarn; Nate Lombard Poirot; Xinyang Xu; M Cenk Çavuşoğlu
Journal:  IEEE Robot Autom Lett       Date:  2018-11-19

4.  Three Dimensional Modeling of an MRI Actuated Steerable Catheter System.

Authors:  Taoming Liu; M Cenk Cavuşoğlu
Journal:  IEEE Int Conf Robot Autom       Date:  2014

5.  Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter.

Authors:  Aravinda Thiagalingam; Andre D'Avila; Lori Foley; J Luis Guerrero; Hendrik Lambert; Giovanni Leo; Jeremy N Ruskin; Vivek Y Reddy
Journal:  J Cardiovasc Electrophysiol       Date:  2010-02-01

6.  The Effect of Contact Force in Atrial Radiofrequency Ablation: Electroanatomical, Cardiovascular Magnetic Resonance, and Histological Assessment in a Chronic Porcine Model.

Authors:  Steven E Williams; James Harrison; Henry Chubb; Lars Ølgaard Bloch; Niels Peter Andersen; Høgni Dam; Rashed Karim; John Whitaker; Jaswinder Gill; Michael Cooklin; C Aldo Rinaldi; Kawal Rhode; Matthew Wright; Tobias Schaeffter; Won Yong Kim; Henrik Jensen; Reza Razavi; Mark D O'Neill
Journal:  JACC Clin Electrophysiol       Date:  2015-08-20

7.  Modeling and Validation of the Three-Dimensional Deflection of an MRI-Compatible Magnetically Actuated Steerable Catheter.

Authors:  Taoming Liu; Nate Lombard Poirot; Dominique Franson; Nicole Seiberlich; Mark A Griswold; M Cenk Cavusoglu
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-22       Impact factor: 4.538

8.  Heart Motion Prediction Based on Adaptive Estimation Algorithms for Robotic Assisted Beating Heart Surgery.

Authors:  E Erdem Tuna; Timothy J Franke; Ozkan Bebek; Akira Shiose; Kiyotaka Fukamachi; M Cenk Cavuşoğlu
Journal:  IEEE Trans Robot       Date:  2013-02-01       Impact factor: 5.567

9.  Quantitative magnetic resonance imaging analysis of the relationship between contact force and left atrial scar formation after catheter ablation of atrial fibrillation.

Authors:  Christian Sohns; Rashed Karim; James Harrison; Aruna Arujuna; Nick Linton; Richard Sennett; Hendrik Lambert; Giovanni Leo; Steven Williams; Reza Razavi; Matt Wright; Tobias Schaeffter; Mark O'Neill; Kawal Rhode
Journal:  J Cardiovasc Electrophysiol       Date:  2013-11-08

10.  Contact Stability and Contact Safety of a Magnetic Resonance Imaging-Guided Robotic Catheter Under Heart Surface Motion.

Authors:  Ran Hao; E Erdem Tuna; M Cenk Çavuşoğlu
Journal:  J Dyn Syst Meas Control       Date:  2021-02-23       Impact factor: 1.640

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.