Contact Stability and Contact Safety of a Magnetic Resonance Imaging-Guided Robotic Catheter Under Heart Surface Motion.

Ran Hao1, E Erdem Tuna1, M Cenk Çavuşoğlu1.   

Abstract

Contact force quality is one of the most critical factors for safe and effective lesion formation during catheter based atrial fibrillation ablation procedures. In this paper, the contact stability and contact safety of a novel magnetic resonance imaging (MRI)-actuated robotic cardiac ablation catheter subject to surface motion disturbances are studied. First, a quasi-static contact force optimization algorithm, which calculates the actuation needed to achieve a desired contact force at an instantaneous tissue surface configuration is introduced. This algorithm is then generalized using a least-squares formulation to optimize the contact stability and safety over a prediction horizon for a given estimated heart motion trajectory. Four contact force control schemes are proposed based on these algorithms. The first proposed force control scheme employs instantaneous heart position feedback. The second control scheme applies a constant actuation level using a quasi-periodic heart motion prediction. The third and the last contact force control schemes employ a generalized adaptive filter-based heart motion prediction, where the former uses the predicted instantaneous position feedback, and the latter is a receding horizon controller. The performance of the proposed control schemes is compared and evaluated in a simulation environment.
Copyright © 2021 by ASME.

Entities:  

Year:  2021        PMID: 33994580      PMCID: PMC8086176          DOI: 10.1115/1.4049837

Source DB:  PubMed          Journal:  J Dyn Syst Meas Control        ISSN: 0022-0434            Impact factor:   1.640


  37 in total

1.  Determination of urethral catheter surface lubricity.

Authors:  Katarzyna Kazmierska; Maciej Szwast; Tomasz Ciach
Journal:  J Mater Sci Mater Med       Date:  2007-12-12       Impact factor: 3.896

2.  Relationship between catheter forces, lesion characteristics, "popping," and char formation: experience with robotic navigation system.

Authors:  Luigi Di Biase; Andrea Natale; Conor Barrett; Carmela Tan; Claude S Elayi; Chi Keong Ching; Paul Wang; Amin Al-Ahmad; Mauricio Arruda; J David Burkhardt; Brian J Wisnoskey; Punam Chowdhury; Shari De Marco; Luciana Armaganijan; Kenneth N Litwak; Robert A Schweikert; Jennifer E Cummings
Journal:  J Cardiovasc Electrophysiol       Date:  2008-11-11

3.  Control of intravascular catheters using an array of active steering coils.

Authors:  N Gudino; J A Heilman; J J Derakhshan; J L Sunshine; J L Duerk; M A Griswold
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

4.  Modeling and estimation of tip contact force for steerable ablation catheters.

Authors:  Mahta Khoshnam; Allan C Skanes; Rajni V Patel
Journal:  IEEE Trans Biomed Eng       Date:  2015-01-09       Impact factor: 4.538

5.  Design of a Magnetic Resonance Imaging Guided Magnetically Actuated Steerable Catheter.

Authors:  Taoming Liu; Nate Lombard Poirot; Tipakorn Greigarn; M Cenk Çavuşoğlu
Journal:  J Med Device       Date:  2017-05-03       Impact factor: 0.582

Review 6.  Left atrial anatomy revisited.

Authors:  Siew Yen Ho; José Angel Cabrera; Damian Sanchez-Quintana
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-02

7.  Frictional properties of light-activated antimicrobial polymers in blood vessels.

Authors:  Polina Prokopovich; Stefano Perni; Clara Piccirillo; Jonathan Pratten; Ivan P Parkin; Michael Wilson
Journal:  J Mater Sci Mater Med       Date:  2009-09-27       Impact factor: 3.896

8.  Modeling and Validation of the Three-Dimensional Deflection of an MRI-Compatible Magnetically Actuated Steerable Catheter.

Authors:  Taoming Liu; Nate Lombard Poirot; Dominique Franson; Nicole Seiberlich; Mark A Griswold; M Cenk Cavusoglu
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-22       Impact factor: 4.538

9.  Heart Motion Prediction Based on Adaptive Estimation Algorithms for Robotic Assisted Beating Heart Surgery.

Authors:  E Erdem Tuna; Timothy J Franke; Ozkan Bebek; Akira Shiose; Kiyotaka Fukamachi; M Cenk Cavuşoğlu
Journal:  IEEE Trans Robot       Date:  2013-02-01       Impact factor: 5.567

10.  Towards active tracking of beating heart motion in the presence of arrhythmia for robotic assisted beating heart surgery.

Authors:  E Erdem Tuna; Jamshid H Karimov; Taoming Liu; Özkan Bebek; Kiyotaka Fukamachi; M Cenk Çavuşoğlu
Journal:  PLoS One       Date:  2014-07-21       Impact factor: 3.240

View more
  1 in total

1.  A Probabilistic Approach for Contact Stability and Contact Safety Analysis of Robotic Intracardiac Catheter.

Authors:  Ran Hao; M Cenk Çavuşoğlu
Journal:  J Dyn Syst Meas Control       Date:  2021-05-10       Impact factor: 1.640

  1 in total