Literature DB >> 34292121

Validation study of canine serum cortisol measurement with the Immulite 2000 Xpi cortisol immunoassay.

Jérémie Korchia1, Kathleen P Freeman2.   

Abstract

We report the results of validation of canine serum cortisol determination with the Immulite 2000 Xpi cortisol immunoassay (Siemens), with characterization of precision (CV), accuracy (spiking-recovery [SR] bias), and observed total error (TEo = bias + 2CV) across the reportable range, specifically at the most common interpretation thresholds for dynamic testing. Imprecision increased at increasing rate with decreasing serum cortisol concentration and bias was low, resulting in increasing TEo with decreasing serum cortisol concentration. Inter-laboratory comparison study allowed for determination of range-based bias (RB) and average bias (AB). At 38.6 and 552 nmol/L (1.4 and 20 μg/dL), between-run CV was 10% and 7.5%, respectively, and TEo ~30% and ~20%, respectively (TEo remained similar regardless of the considered bias: SR, RB, or AB). These analytical performance parameters should be considered in the interpretation of results and for future expert consensus discussions to determine recommendations for allowable total error (TEa). Importantly, the commonly used thresholds for interpretation of results were determined ~40 y ago with different methods of measurements and computation, hence updating is desirable. Quality control material (QCM) had between-run imprecision of 4% for QCM1 and 7% for QCM2; the bias was minimal for both levels. Acceptable QC rules are heavily dependent on the desired TEa for the QCM system (TEaQCM), itself limited by the desired clinical TEa. At low TEaQCM (20-33%), almost no rules were acceptable, whereas at high TEaQCM (50%), almost all rules were acceptable; further investigation is needed to determine which TEaQCM can be guaranteed by simple QC rules.

Entities:  

Keywords:  Cushing; accuracy; bias; cortisol; dogs; endocrinology; precision; total error

Mesh:

Substances:

Year:  2021        PMID: 34292121      PMCID: PMC8366243          DOI: 10.1177/10406387211029247

Source DB:  PubMed          Journal:  J Vet Diagn Invest        ISSN: 1040-6387            Impact factor:   1.569


  46 in total

Review 1.  Bias in clinical chemistry.

Authors:  Elvar Theodorsson; Bertil Magnusson; Ivo Leito
Journal:  Bioanalysis       Date:  2014       Impact factor: 2.681

2.  Diagnosis of spontaneous canine hyperadrenocorticism: 2012 ACVIM consensus statement (small animal).

Authors:  E N Behrend; H S Kooistra; R Nelson; C E Reusch; J C Scott-Moncrieff
Journal:  J Vet Intern Med       Date:  2013-09-20       Impact factor: 3.333

3.  Single-antibody technique for radioimmunoassay of cortisol in unextracted serum or plasma.

Authors:  L B Foster; R T Dunn
Journal:  Clin Chem       Date:  1974-03       Impact factor: 8.327

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Concentrations of noncortisol adrenal steroids in response to ACTH in dogs with adrenal-dependent hyperadrenocorticism, pituitary-dependent hyperadrenocorticism, and nonadrenal illness.

Authors:  W E Monroe; D L Panciera; K L Zimmerman
Journal:  J Vet Intern Med       Date:  2012-06-18       Impact factor: 3.333

6.  Canine hyperadrenocorticism due to adrenocortical neoplasia. Pretreatment evaluation of 41 dogs.

Authors:  C E Reusch; E C Feldman
Journal:  J Vet Intern Med       Date:  1991 Jan-Feb       Impact factor: 3.333

7.  Plasma cortisol concentrations in dogs given cortisone or placebo by mouth.

Authors:  A D Watson; D B Church; D R Emslie
Journal:  Res Vet Sci       Date:  1993-11       Impact factor: 2.534

8.  Comparison of radioimmunoassay and chemiluminescent assay methods to estimate canine blood cortisol concentrations.

Authors:  N J Russell; S Foster; P Clark; I D Robertson; D Lewis; P J Irwin
Journal:  Aust Vet J       Date:  2007-12       Impact factor: 1.281

9.  Plasma cortisol response to ketoconazole administration in dogs with hyperadrenocorticism.

Authors:  E C Feldman; D S Bruyette; R W Nelson; T B Farver
Journal:  J Am Vet Med Assoc       Date:  1990-07-01       Impact factor: 1.936

Review 10.  Understanding Bland Altman analysis.

Authors:  Davide Giavarina
Journal:  Biochem Med (Zagreb)       Date:  2015-06-05       Impact factor: 2.313

View more
  2 in total

1.  Total observed error, total allowable error, and QC rules for canine serum and urine cortisol achievable with the Immulite 2000 Xpi cortisol immunoassay.

Authors:  Jeremie Korchia; Kathleen P Freeman
Journal:  J Vet Diagn Invest       Date:  2022-03       Impact factor: 1.569

2.  Validation study of canine urine cortisol measurement with the Immulite 2000 Xpi cortisol immunoassay.

Authors:  Jeremie Korchia; Kathleen P Freeman
Journal:  J Vet Diagn Invest       Date:  2021-07-18       Impact factor: 1.569

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.