Literature DB >> 27481169

Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure.

Tianjiao Zhang1,2, Chuanbao Zhang1,2, Haijian Zhao1,2, Jie Zeng1,2, Jiangtao Zhang1,2, Weiyan Zhou1,2, Ying Yan1,2, Yufei Wang1,2, Mo Wang1,2, Wenxiang Chen3,4.   

Abstract

Accurate and precise glucose measurements are requisite for ensuring appropriate diagnosis and management of diseases related to hyperglycemia or hypoglycemia. It is necessary to have a higher order method to provide an accuracy base to which routine methods can be compared. We developed and evaluated a highly reliable measurement procedure based on isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) with a simple one-step derivatization. An appropriate amount of serum was accurately weighed and spiked with an isotope-labeled internal standard. After protein precipitation, the supernatant was reacted with 1-phenyl-3-methyl-5-pyrazolone for chemical structural transformation. The glucose derivatives were analyzed with LC-MS/MS in positive electrospray ionization mode. The within-run and total CVs ranged from 0.28 to 0.42 % and from 0.42 to 0.76 %, respectively, for a concentration range of 1.691 to 15.676 mmol/L. A regression comparison of the presented method to an existing RMP based on ID GC-MS showed agreement with no statistical difference (Y = 0.9985X-0.008; 95 % CI for the slope, 0.9966 to 1.001; 95 % CI for the intercept, -0.012 to 0.019). The structural analogs of glucose with a molecular mass of 180 were tested, and no significant interference effect was found. The limit of quantification was estimated to 0.8 ng glucose in absolute amount. This method is accurate, simple, and can serve as a candidate reference measurement procedure (RMP) in the establishment of a serum glucose reference system.

Entities:  

Keywords:  1-Phenyl-3-methyl-5-pyrazolone; Liquid chromatography-tandem mass spectrometry; Serum glucose

Mesh:

Substances:

Year:  2016        PMID: 27481169     DOI: 10.1007/s00216-016-9817-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  Candidate reference measurement procedure based on HPAEC-PAD for the development of certified reference materials for monosaccharides in serum.

Authors:  Min-Seon Seo; Ji-Seon Jeong; Mariam M Abady; Ha-Jeong Kwon
Journal:  Anal Bioanal Chem       Date:  2021-07-20       Impact factor: 4.142

2.  Do We Need the Replacement of YSI 2300? A View from the Clinical Laboratory.

Authors:  Loukia Spanou; Konstantinos Makris
Journal:  J Diabetes Sci Technol       Date:  2021-05-17

3.  Inductively Coupled Plasma Mass Spectrometry as a Reference Method to Evaluate Serum Calcium Measurement Bias and the Commutability of Processed Materials during Routine Measurements.

Authors:  Hai-Jian Zhao; Meng-Lei Ge; Yin Yan; Tian-Jiao Zhang; Jie Zeng; Wei-Yan Zhou; Yu-Fei Wang; Qing-Hui Meng; Chuan-Bao Zhang
Journal:  Chin Med J (Engl)       Date:  2018-07-05       Impact factor: 2.628

4.  Glucose Sensing Using Capacitive Biosensor Based on Polyvinylidene Fluoride Thin Film.

Authors:  Ambran Hartono; Edi Sanjaya; Ramli Ramli
Journal:  Biosensors (Basel)       Date:  2018-01-30

Review 5.  The Oral Glucose Tolerance Test-Is It Time for a Change?-A Literature Review with an Emphasis on Pregnancy.

Authors:  Delia Bogdanet; Paula O'Shea; Claire Lyons; Amir Shafat; Fidelma Dunne
Journal:  J Clin Med       Date:  2020-10-27       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.