Not long ago, we were all transfixed by 50th anniversary tributes to humankind’s most daring achievement to date, the Apollo 11 moon landing. At 2 hours 44 minutes and 19 seconds after launch, the crew performed another jaw-dropping procedure. Translunar injection, a 6-minute burst of Saturn V engines, thrust Apollo 11 out of a low, circular parking orbit around Earth and catapulted it at 25,000 mph toward its precise target: the Moon. The 1969 Moon landing was a monumental feat of human perseverance, technological precision, and risk management. But behind the thousands of protocols and backup systems were hundreds of commands for “Mission Abort”. First and foremost was the safety of the 3 occupants. Exploration of scientific frontiers involves detailed planning, precise execution, and the awareness of when, for safety purposes, to say when. One of the most exciting frontiers in our field is the healthy debate about kinematic alignment (KA), which advocates positioning prosthetics relative to individual constitutional anatomy. Evidence suggests a myriad of benefits over the previous mainstay, mechanical alignment (MA), including significantly improved soft-tissue balance requiring fewer releases [[1], [2], [3], [4], [5]] and enhanced restoration of physiologic gait patterns, adduction moments, and native knee kinematics [[6], [7], [8]]. Comparative clinical studies have demonstrated either equivalence or superiority to MA [3,[9], [10], [11], [12], [13], [14]]. Single-surgeon series [15] and 7-year registry data [16] have alleviated concerns of premature prosthetic failure. So, is there a problem, Houston? It is certainly hard to argue against the survivorship of MA, as 90% of MA patients still have a functioning prosthesis after 20 years [17,18]). Is it too early to throw away this technique founded on the fundamental principle of “first, do no harm”? Unfortunately, the one-size-fits-all approach of MA does not consider the wide range of normal knee anatomy, often resulting in significant gap asymmetry, soft-tissue imbalance, and unnatural joint line obliquities and heights. These factors may well contribute to the nearly 20% dissatisfaction rates reported by our MA patients. So yes, Houston, we do have a problem …but truly unbounded KA is probably not the answer either, particularly in patients with extreme anatomies. In these patients, bony landmarks can no longer be trusted to provide a target for a patient’s constitutional knee alignment. Therefore, where to from here? Well, as with any scientific endeavor, accurate planning, precise execution, and knowing when to abort must be the mantra as we explore options such as restricted KA (rKA).

Detailed preoperative planning

Detailed premission planning in 1969 ensured Apollo 11 would enter lunar orbit with pin-point accuracy. In 2021, preoperative planning using high-quality imaging (long leg radiographs, computed tomography scans, magnetic resonance images) provides the accuracy to hit the correct alignment targets. This sort of imaging can quantify the 2 independent variables of joint line obliquity and prearthritic limb alignment (arithmetic hip-knee-ankle angle) [19]. These parameters define each patient’s Coronal Plane Alignment of the Knee phenotype [20], a critical categorization for understanding how knee soft-tissue laxities will behave once implants are positioned …in MA or KA. Furthermore, when target boundaries are imposed, these data allow predictions for when minor soft-tissue releases will be required. However, it is important to acknowledge that both MA and KA reference bony anatomy. Future planning must go beyond describing constitutional phenotypes and, with the assistance of intraoperative algorithms, begin quantifying native soft-tissue laxities.

Precise execution

Unfortunately, many current intraoperative techniques fall short of ideal execution in total knee arthroplasty. Conventional cutting guides lack the required precision, as 30% of knees will have errors >3° off target [21,22]. Patient-specific cutting guides have not proven to be any more effective, and neither technique allows for intraoperative resection validation or assessment of soft-tissue laxities [23]. Precision technologies can mitigate real-world risks. Apollo spacecrafts used 3 sophisticated positioning systems to stay on target. Computer-assisted surgical navigation (CAS), with or without the use of robotic cutting arms, is the current undisputed gold standard for knee alignment precision, as it minimizes deviations from the intended target [21,22]. Most robotic platforms also provide virtual gap balancing algorithms that can restore native soft-tissue laxities and reduce the requirements for soft-tissue releases before any bony resections. The risk of “Mission abort” is minimized now that true precision is available in the operating room.

Restricted boundaries

Nevertheless, routine restoration of constitutional alignment should not be the goal for every patient. For those with atypical anatomy (eg, trauma, extra-articular deformity), KA without boundaries has the potential to inappropriately restore angles that are biomechanically unsound (eg, constitutional varus of 9°). Worse, imprecise guides can easily compound alignment errors, increasing the original deformity (say, to 12°). rKA provides important protections by imposing “safe zone” alignment boundaries to avoid extreme outliers [3,13,24]. With CAS or robotic techniques, we now use Food and Drug Administration–approved boundaries of 6° varus to 3° valgus for final HKA and tibial coronal resections; 6° valgus to 3° varus for distal femoral resections; and ±6° to the surgical TEA for femoral rotation. These boundaries encompass 85% of normal individuals [25]. With an rKA philosophy, preoperative planning and intraoperative CAS validation will minimize implant failure risk and maximize chances that the correct target alignments are achieved, bone resection thicknesses are minimized, and as a result, normal soft-tissue laxities are restored.

Keep the journey on course

Full optical navigation, ideally with robotic cutting arms, allows for virtual implant adjustments before any resections to optimize restoration of soft-tissue laxities. Surgeon-defined assessment of soft-tissue balance has been shown to be a poor predictor of the true state of knee balance [26,27], but pressure sensors and other balancing instruments offer more objective means to quantify soft-tissue laxities. Buzz Aldrin said, "Your mind is like a parachute: If it isn't open, it doesn't work." We must keep an open mind in this evolving field of research as adoption of rKA increases. High-quality randomized trials are needed to determine clinical effectiveness, and registry surveillance is needed to track implant survivorship. We will all have the fortune of working in a more reliable total knee arthroplasty universe when we use modern imaging to understand more about our patients, modern surgical technologies to precisely navigate the limb …and modern restricted boundaries to know when to abort.

Conflicts of interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this article.
  26 in total

1.  Kinematic TKA using navigation: Surgical technique and initial results.

Authors:  J R B Hutt; M-A LeBlanc; V Massé; M Lavigne; P-A Vendittoli
Journal:  Orthop Traumatol Surg Res       Date:  2016-01-06       Impact factor: 2.256

2.  Kinematically versus mechanically aligned total knee arthroplasty.

Authors:  H Gene Dossett; George J Swartz; Nicolette A Estrada; George W LeFevre; Bertram G Kwasman
Journal:  Orthopedics       Date:  2012-02-17       Impact factor: 1.390

3.  How Accurately Can Soft Tissue Balance Be Determined in Total Knee Arthroplasty?

Authors:  Samuel J MacDessi; Monther A Gharaibeh; Ian A Harris
Journal:  J Arthroplasty       Date:  2018-10-11       Impact factor: 4.757

4.  Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty.

Authors:  Yasuo Niki; Takeo Nagura; Katsuya Nagai; Shu Kobayashi; Kengo Harato
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-12-04       Impact factor: 4.342

5.  The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus.

Authors:  Johan Bellemans; William Colyn; Hilde Vandenneucker; Jan Victor
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

6.  The arithmetic HKA (aHKA) predicts the constitutional alignment of the arthritic knee compared to the normal contralateral knee: a matched-pairs radiographic study.

Authors:  Samuel J MacDessi; William Griffiths-Jones; Ian A Harris; Johan Bellemans; Darren B Chen
Journal:  Bone Jt Open       Date:  2020-11-02

7.  No Difference in 5-year Clinical or Radiographic Outcomes Between Kinematic and Mechanical Alignment in TKA: A Randomized Controlled Trial.

Authors:  Simon W Young; Niall P T Sullivan; Matthew L Walker; Sherina Holland; Ali Bayan; Bill Farrington
Journal:  Clin Orthop Relat Res       Date:  2020-06       Impact factor: 4.755

8.  How long does a knee replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up.

Authors:  Jonathan T Evans; Robert W Walker; Jonathan P Evans; Ashley W Blom; Adrian Sayers; Michael R Whitehouse
Journal:  Lancet       Date:  2019-02-14       Impact factor: 79.321

9.  Coronal Plane Alignment of the Knee (CPAK) classification.

Authors:  Samuel J MacDessi; William Griffiths-Jones; Ian A Harris; Johan Bellemans; Darren B Chen
Journal:  Bone Joint J       Date:  2021-02       Impact factor: 5.082

10.  Higher satisfaction after total knee arthroplasty using restricted inverse kinematic alignment compared to adjusted mechanical alignment.

Authors:  Philip Winnock de Grave; Thomas Luyckx; Kurt Claeys; Thomas Tampere; Jonas Kellens; Jacobus Müller; Paul Gunst
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-07-31       Impact factor: 4.114

View more
  3 in total

1.  Alignment philosophy influences trochlea recreation in total knee arthroplasty: a comparative study using image-based robotic technology.

Authors:  Jobe Shatrov; Benoit Coulin; Cécile Batailler; Elvire Servien; Bill Walter; Sebastien Lustig
Journal:  Int Orthop       Date:  2022-09-16       Impact factor: 3.479

2.  Can Patella Instability After Total Knee Arthroplasty be Treated With Medial Patellofemoral Ligament Reconstruction?

Authors:  Jobe Shatrov; Antoine Colas; Gaspard Fournier; Cécile Batailler; Elvire Servien; Sébastien Lustig
Journal:  Arthroplast Today       Date:  2022-06-04

3.  Arithmetic hip-knee-ankle angle and stressed hip-knee-ankle angle: equivalent methods for estimating constitutional lower limb alignment in kinematically aligned total knee arthroplasty.

Authors:  Payam Tarassoli; Jil A Wood; Darren B Chen; Will Griffiths-Jones; Johan Bellemans; Samuel J MacDessi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-07-11       Impact factor: 4.114

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.