Literature DB >> 3420280

Advanced multiple-beam equalization radiography in chest radiology: a simulated nodule detection study.

L J Kool1, D L Busscher, H Vlasbloem, J Hermans, P C vd Merwe, P R Algra, W Herstel.   

Abstract

To evaluate the efficacy of AMBER, a multiple-beam equalization system for chest radiography, the authors performed a nodule detection study using an anthropomorphic chest phantom. AMBER and conventional images were compared. The images were read by four observers, and analysis was done by means of modified receiver-operating characteristic (ROC) curves (free ROC curves [FROC]). The results of the FROC analysis show a significant increase in the detectability of nodules (P less than .001) projected over the mediastinum with the use of AMBER. No significant difference between AMBER and conventional images was noted in detectability of nodules projected over the lung.

Mesh:

Year:  1988        PMID: 3420280     DOI: 10.1148/radiology.169.1.3420280

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

2.  Digital radiography: comparison of different methods for imaging of the thorax and the gastrointestinal tracts.

Authors:  H P Busch
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

Review 3.  Medical imaging.

Authors:  L Kreel
Journal:  Postgrad Med J       Date:  1991-04       Impact factor: 2.401

4.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

5.  Role of equalisation mammography of dense breasts.

Authors:  D B Plewes; J M Sabol; I Soutar; A Chevrier; R Shumak
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

6.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.