| Literature DB >> 34168470 |
Esther Pollack1, Stephen Johnston2, William J Petraiuolo3, Sanjoy Roy1, Thibaut Galvain4.
Abstract
PURPOSE: To estimate the cost impact of using the ECHELON CIRCULAR™ Powered Stapler (ECP) compared with manual circular staplers (standard of care, SOC) among patients undergoing colectomy procedures that involve left-sided anastomosis.Entities:
Keywords: anastomotic leak; circular stapler; colectomy; costs; outcomes
Year: 2021 PMID: 34168470 PMCID: PMC8217739 DOI: 10.2147/CEOR.S305296
Source DB: PubMed Journal: Clinicoecon Outcomes Res ISSN: 1178-6981
Figure 1Model structure.
Model Inputs
| Anastomotic Leak | Source | |
|---|---|---|
| Incremental Cost (2020 USD) | $12,869 | [ |
| Incremental LOS (days) | 5.3 | [ |
| Non home discharge (incremental % of patients) | 4.40% | [ |
| Readmission (incremental % of patients) | 7.40% | [ |
| Cost, manual stapler (2020 USD) | $298 | Ethicon sales data (average price), a flat 25% range was applied |
| Cost, ECP (2020 USD) | $412 |
Probabilistic Sensitivity Analysis
| PSA Parameters | Base Case Value | Lower Range | Upper Range | Distribution | Source |
|---|---|---|---|---|---|
| Baseline leak probability with manual stapler | 0.069 | 0.055 | 0.083 | Beta | [ |
| Leak probability with ECP | 0.018 | 0.002 | 0.039 | Beta | [ |
| Cost without leak | $23,763 | $23,615 | $23,910 | Gamma | [ |
| Cost with leak | $36,632 | $36,404 | $36,859 | Gamma | [ |
| LOS with leak, days | 12.1 | 12.0 | 12.2 | Gamma | [ |
| LOS without leak, days | 6.8 | 6.7 | 6.8 | Gamma | [ |
| Probability of non-home discharge with leak | 0.069 | 0.065 | 0.073 | Beta | [ |
| Probability of non-home discharge without leak | 0.025 | 0.023 | 0.026 | Beta | [ |
| Probability of 90-day readmission with leak | 0.269 | 0.266 | 0.272 | Beta | [ |
| Probability of 90-day readmission without leak | 0.195 | 0.192 | 0.197 | Beta | [ |
| Cost of manual stapler | $298 | $224 | $373 | Gamma | Ethicon sales data (average price) - a flat 25% range was applied |
| Cost of ECP | $412 | $309 | $515 | Gamma | Ethicon sales data (average price) - a flat 25% range was applied |
Figure 2Tornado diagram of annual savings (assumes 100 patients) related to anastomotic leak complication with one-way sensitivity analysis results.
Figure 3Boxplot of the budget impact (annual savings) for leak occurrence among 100 patients, according to the probabilistic sensitivity analysis.
Figure 4Total annual costs by simulation run for occurrence of anastomotic leaks among 100 patients with each circular stapler type, according to the probabilistic sensitivity analysis.
Figure 5Histogram of the number of readmissions avoided due to leak occurrence among 100 patients, according to the probabilistic sensitivity analysis.