Literature DB >> 34110426

Longitudinal reproducibility of attenuation measurements on virtual unenhanced images: multivendor dual-energy CT evaluation.

Simon Lennartz1,2, Anushri Parakh1, Jinjin Cao1, Avinash Kambadakone3.   

Abstract

OBJECTIVES: The accuracy of virtual unenhanced (VUE) images has been extensively investigated, yet data on their longitudinal reproducibility is limited. The study purpose was to evaluate the longitudinal reproducibility of VUE attenuation measurements on three different dual-energy CT (DECT) scanner types.
METHODS: A total of 137 patients with repeated abdominal DECT either on a rapid kV switching (rsDECT; n = 46), a dual-layer detector (dlDECT; n = 43), or a dual-source scanner (dsDECT; n = 48) were retrospectively included. Attenuation was measured on VUE and corresponding contrast-enhanced images in the liver, spleen, kidneys, aorta, portal vein, and fat. Longitudinal reproducibility was evaluated by calculating the absolute inter-scan differences (HU) and the inter-scan variation (%). Measurement pairs with differences ≤ 10 HU were considered reproducible. Influence of contrast-enhanced attenuation on VUE reproducibility was analyzed using linear regression.
RESULTS: The scanner-specific cohorts showed similar age (p-range: 0.35-0.99), sex (p-range: 0.68-1), body weight (p-range: 0.26-0.87), body diameter (p-range: 0.34-0.76), and inter-scan time (p-range: 0.52-0.83). In total, 94.9% of VUE measurements were reproducible for rsDECT, 93.8% for dlDECT, and 90.6% for dsDECT. Overall inter-scan variation was lowest in fat (4.0 (1.7-8.2)%) and highest in tissues with high contrast enhancement: the aorta (13.3 (4.6-21.3)%), portal vein (10.8 (5.7-19.8)%), and kidneys (10.7 (3.9-18.0)%). Significant differences in inter-scan variation were found between the scanner types for the aorta, portal vein, kidneys, and spleen. Inter-scan differences in contrast-enhanced attenuation significantly influenced inter-scan differences in VUE attenuation (p < 0.001; t-ratio: 4.34).
CONCLUSIONS: Longitudinal reproducibility of VUE attenuation was high for all scanners, yet inter-scan variation of VUE attenuation was influenced by contrast enhancement, showing greatest magnitude and discrepancy between scanner types in vessels and the kidneys. KEY POINTS: • We found that 94.9% of attenuation measurements on virtual unenhanced images were reproducible for rapid kV switching DECT, 93.8% for dual-layer detector DECT, and 90.6% for dual-source DECT. • Inter-scan variation of attenuation in virtual unenhanced images was comparable between the three scanner types in the liver and fat, whereas inter-scan variation in the spleen, kidneys, portal vein, and aorta showed significant differences between scanner types (p < 0.05). • Inter-scan attenuation differences in contrast-enhanced images significantly influenced inter-scan differences in virtual unenhanced attenuation (p < 0.001, t-ratio: 4.34), suggesting a residual impact of contrast enhancement differences between examinations.

Entities:  

Keywords:  Contrast media; Reproducibility of results; Tomography, X-ray computed

Year:  2021        PMID: 34110426     DOI: 10.1007/s00330-021-08083-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

Review 1.  Multidetector CT angiography for acute gastrointestinal bleeding: technique and findings.

Authors:  José M Artigas; Milagros Martí; Jorge A Soto; Helena Esteban; Inmaculada Pinilla; Eugenia Guillén
Journal:  Radiographics       Date:  2013 Sep-Oct       Impact factor: 5.333

2.  Management of the Incidental Renal Mass on CT: A White Paper of the ACR Incidental Findings Committee.

Authors:  Brian R Herts; Stuart G Silverman; Nicole M Hindman; Robert G Uzzo; Robert P Hartman; Gary M Israel; Deborah A Baumgarten; Lincoln L Berland; Pari V Pandharipande
Journal:  J Am Coll Radiol       Date:  2017-06-23       Impact factor: 5.532

Review 3.  Acute gastrointestinal bleeding: contrast-enhanced MDCT.

Authors:  W Yoon; Y Y Jeong; J K Kim
Journal:  Abdom Imaging       Date:  2006 Jan-Feb

4.  Management of Incidental Liver Lesions on CT: A White Paper of the ACR Incidental Findings Committee.

Authors:  Richard M Gore; Perry J Pickhardt; Koenraad J Mortele; Elliot K Fishman; Jeanne M Horowitz; Claus J Fimmel; Mark S Talamonti; Lincoln L Berland; Pari V Pandharipande
Journal:  J Am Coll Radiol       Date:  2017-09-18       Impact factor: 5.532

5.  Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant.

Authors:  Anno Graser; Christoph R Becker; Michael Staehler; Dirk A Clevert; Michael Macari; Niko Arndt; Konstantin Nikolaou; Wieland Sommer; Christian Stief; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Invest Radiol       Date:  2010-07       Impact factor: 6.016

6.  Protocol analysis of dual-energy CT for optimization of kidney stone detection in virtual non-contrast reconstructions.

Authors:  Matthias Lazar; Helmut Ringl; Pascal Baltzer; Daniel Toth; Christian Seitz; Bernhard Krauss; Ewald Unger; Stephan Polanec; Dietmar Tamandl; Christian J Herold; Michael Toepker
Journal:  Eur Radiol       Date:  2020-04-03       Impact factor: 5.315

7.  Can single-phase dual-energy CT reliably identify adrenal adenomas?

Authors:  A Helck; N Hummel; F G Meinel; T Johnson; K Nikolaou; A Graser
Journal:  Eur Radiol       Date:  2014-05-08       Impact factor: 5.315

8.  Virtual unenhanced images of the abdomen with second-generation dual-source dual-energy computed tomography: image quality and liver lesion detection.

Authors:  Carlo Nicola De Cecco; Anna Darnell; Napoleón Macías; Juan Ramón Ayuso; Sonia Rodríguez; Jordi Rimola; Mario Pagés; Angeles García-Criado; Marco Rengo; Andrea Laghi; Carmen Ayuso
Journal:  Invest Radiol       Date:  2013-01       Impact factor: 6.016

9.  Adrenal Incidentaloma triage with single-source (fast-kilovoltage switch) dual-energy CT.

Authors:  Daniel I Glazer; Katherine E Maturen; Ravi K Kaza; Isaac R Francis; Nahid R Keshavarzi; Robert A Parker; Joel F Platt
Journal:  AJR Am J Roentgenol       Date:  2014-08       Impact factor: 3.959

10.  Evaluation of the liver with virtual non-contrast: single institution study in 149 patients undergoing TAVR planning.

Authors:  Kai Roman Laukamp; Simon Lennartz; Vivian Ho; Nils Große Hokamp; David Zopfs; Amit Gupta; Frank Philipp Graner; Jan Borggrefe; Robert Gilkeson; Nikhil Ramaiya
Journal:  Br J Radiol       Date:  2020-01-02       Impact factor: 3.039

View more