Literature DB >> 23070097

Virtual unenhanced images of the abdomen with second-generation dual-source dual-energy computed tomography: image quality and liver lesion detection.

Carlo Nicola De Cecco1, Anna Darnell, Napoleón Macías, Juan Ramón Ayuso, Sonia Rodríguez, Jordi Rimola, Mario Pagés, Angeles García-Criado, Marco Rengo, Andrea Laghi, Carmen Ayuso.   

Abstract

PURPOSES: We aimed to analyze the image quality, CT number, artifacts, radiation dose reduction, and coverage in abdominal virtual unenhanced (VU) and conventional unenhanced (CU) data sets obtained with a second-generation dual-energy computed tomography and to compare the sensitivity of VU and CU data sets for liver lesion detection.
MATERIALS AND METHODS: One hundred eleven patients underwent triphasic abdominal CT examination that included single-energy CU and dual-energy arterial and portal phases. Virtual unenhanced images were generated from arterial (AVU) and portal (PVU) phases. Two abdominal radiologists independently (a) analyzed the image quality using a 5-point scale, CT number, and noise of the abdominal organs and (b) identified and characterized liver lesions in CU, AVU, and PVU. The triphasic abdominal examination was considered the reference standard for liver lesion detection and characterization.
RESULTS: The quality of VU images was mostly excellent but not as good as CU images (P < 0.05). The mean (SD) image quality classified by readers 1 and 2 was 4.9 (0.2; range, 4.7-5.0) and 4.8 (0.5; range, 4.4-4.9) for CU, 4.7 (0.4; range, 4.3-4.9) and 4.6 (0.4; range, 4.2-4.8) for AVU, and 4.7 (0.6; range, 4.1-4.8) and 4.6 (0.4; range, 4.2-4.8) for PVU, respectively. The CT number of the liver, the spleen, the pancreas, the renal cortex and medulla, the aorta, and the retroperitoneal fat was higher in AVU and PVU than in CU images. A total of 270 liver lesions were found in 76 patients. Portal virtual unenhanced data set was more sensitive than AVU and CU were for hypodense lesions smaller than 1 cm. Reader 1 correctly detected 72/144 (50.0%), 61/144 (42.4%), and 55/144 (38.2%) hypodense lesions with PVU, AVU, and CU, respectively; and reader 2 correctly diagnosed 70/144 (48.7%), 62/144 (43.0%), and 53/144 (36.8%) lesions with PVU, AVU, and CU, respectively. Conventional unenhanced data set was more sensitive than AVU or PVU was for small calcified lesions. Reader 1 detected 24/40 (60.0%), 24/40 (60.0%), and 40/40 (100%) with PVU, AVU, and CU, respectively; and reader 2 detected 27/40 (67.5%), (25/40) 62.5%, and 40/40 (100%) with PVU, AVU, and CU, respectively. The dose reduction achieved by omitting the unenhanced acquisition was a mean (SD) of 21.1% (1.2%; P < 0.01).
CONCLUSIONS: Second-generation abdominal VU data sets, despite a mostly excellent image quality, still cannot replace CU images in clinical practice because of limitations in material subtraction. ADVANCES IN KNOWLEDGE: 1. Second-generation abdominal VU data sets yield excellent image quality but are still slightly lower than that of CU. 2. More small hypodense liver lesions were detected in VU images than in CU images; however, a significant number of small calcified lesions were not identified in VU images. 3. Second-generation abdominal VU images are still not ready to replace CU images in clinical practice. Implications for Patient Care: 1. Using VU images in abdominal studies makes it possible to reduce the total radiation dose delivered to patients who need multiphasic acquisition by avoiding precontrast scan. 2. Erroneous material subtraction and incomplete abdominal coverage represent a limit in VU data set application in clinical routine.

Entities:  

Mesh:

Year:  2013        PMID: 23070097     DOI: 10.1097/RLI.0b013e31826e7902

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  19 in total

Review 1.  White paper on pancreatic ductal adenocarcinoma from society of abdominal radiology's disease-focused panel for pancreatic ductal adenocarcinoma: Part II, update on imaging techniques and screening of pancreatic cancer in high-risk individuals.

Authors:  Naveen M Kulkarni; Lorenzo Mannelli; Marc Zins; Priya R Bhosale; Hina Arif-Tiwari; Olga R Brook; Elizabeth M Hecht; Fay Kastrinos; Zhen Jane Wang; Erik V Soloff; Parag P Tolat; Guillermo Sangster; Jason Fleming; Eric P Tamm; Avinash R Kambadakone
Journal:  Abdom Radiol (NY)       Date:  2020-03

Review 2.  Advanced imaging techniques for chronic pancreatitis.

Authors:  Anushri Parakh; Temel Tirkes
Journal:  Abdom Radiol (NY)       Date:  2020-05

3.  Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT.

Authors:  Julian L Wichmann; Andrew D Hardie; U Joseph Schoepf; Lloyd M Felmly; Jonathan D Perry; Akos Varga-Szemes; Stefanie Mangold; Damiano Caruso; Christian Canstein; Thomas J Vogl; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

4.  Dual-energy CT angiography-derived virtual non-contrast images for follow-up of patients with surgically clipped aneurysms: a retrospective study.

Authors:  Su Young Yun; Young Jin Heo; Hae Woong Jeong; Jin Wook Baek; Hye Jung Choo; Gi Won Shin; Sung Tae Kim; Young Gyun Jeong; Ji Young Lee; Hyun Seok Jung
Journal:  Neuroradiology       Date:  2019-01-25       Impact factor: 2.804

5.  Can virtual non-enhanced CT be used to replace true non-enhanced CT for the detection of palpable cervical lymph nodes? A preliminary study.

Authors:  Yaying Yang; Xiaoxia Jia; Yamin Deng; Jiuhong Chen; Long Jiang Zhang
Journal:  Jpn J Radiol       Date:  2014-04-19       Impact factor: 2.374

6.  Longitudinal reproducibility of attenuation measurements on virtual unenhanced images: multivendor dual-energy CT evaluation.

Authors:  Simon Lennartz; Anushri Parakh; Jinjin Cao; Avinash Kambadakone
Journal:  Eur Radiol       Date:  2021-06-10       Impact factor: 5.315

7.  Compatibility of true and virtual unenhanced attenuation in rapid kV-switching dual energy CT.

Authors:  İlkay Çamlıdağ
Journal:  Diagn Interv Radiol       Date:  2020-03       Impact factor: 2.630

8.  Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage.

Authors:  Matteo Bonatti; Fabio Lombardo; Giulia A Zamboni; Patrizia Pernter; Roberto Pozzi Mucelli; Giampietro Bonatti
Journal:  Eur Radiol       Date:  2016-11-23       Impact factor: 5.315

Review 9.  Dual energy CT applications in pancreatic pathologies.

Authors:  Elizabeth George; Jeremy R Wortman; Urvi P Fulwadhva; Jennifer W Uyeda; Aaron D Sodickson
Journal:  Br J Radiol       Date:  2017-09-22       Impact factor: 3.039

10.  Comparative study of hepatic venography using non-linear-blending images, monochromatic images and low-voltage images of dual-energy CT.

Authors:  Q Wang; S Gaofeng; F Xueli; W Lijia; W Runze
Journal:  Br J Radiol       Date:  2014-07-23       Impact factor: 3.039