Literature DB >> 34101198

Using neural networks to extend cropped medical images for deformable registration among images with differing scan extents.

Elizabeth M McKenzie1, Nuo Tong1, Dan Ruan1, Minsong Cao1, Robert K Chin1, Ke Sheng1.   

Abstract

PURPOSE: Missing or discrepant imaging volume is a common challenge in deformable image registration (DIR). To minimize the adverse impact, we train a neural network to synthesize cropped portions of head and neck CT's and then test its use in DIR.
METHODS: Using a training dataset of 409 head and neck CT's, we trained a generative adversarial network to take in a cropped 3D image and output an image with synthesized anatomy in the cropped region. The network used a 3D U-Net generator along with Visual Geometry Group (VGG) deep feature losses. To test our technique, for each of the 53 test volumes, we used Elastix to deformably register combinations of a randomly cropped, full, and synthetically full volume to a single cropped, full, and synthetically full target volume. We additionally tested our method's robustness to crop extent by progressively increasing the amount of cropping, synthesizing the missing anatomy using our network, and then performing the same registration combinations. Registration performance was measured using 95% Hausdorff distance across 16 contours.
RESULTS: We successfully trained a network to synthesize missing anatomy in superiorly and inferiorly cropped images. The network can estimate large regions in an incomplete image, far from the cropping boundary. Registration using our estimated full images was not significantly different from registration using the original full images. The average contour matching error for full image registration was 9.9 mm, whereas our method was 11.6, 12.1, and 13.6 mm for synthesized-to-full, full-to-synthesized, and synthesized-to-synthesized registrations, respectively. In comparison, registration using the cropped images had errors of 31.7 mm and higher. Plotting the registered image contour error as a function of initial preregistered error shows that our method is robust to registration difficulty. Synthesized-to-full registration was statistically independent of cropping extent up to 18.7 cm superiorly cropped. Synthesized-to-synthesized registration was nearly independent, with a -0.04 mm of change in average contour error for every additional millimeter of cropping.
CONCLUSIONS: Different or inadequate in scan extent is a major cause of DIR inaccuracies. We address this challenge by training a neural network to complete cropped 3D images. We show that with image completion, the source of DIR inaccuracy is eliminated, and the method is robust to varying crop extent.
© 2021 American Association of Physicists in Medicine.

Entities:  

Keywords:  deep learning; deformable registration; scan extent

Mesh:

Year:  2021        PMID: 34101198      PMCID: PMC8683602          DOI: 10.1002/mp.15039

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.506


  18 in total

1.  Medical image registration with partial data.

Authors:  Senthil Periaswamy; Hany Farid
Journal:  Med Image Anal       Date:  2005-06-23       Impact factor: 8.545

2.  Impact of the type of imaging modality on target volumes delineation and dose distribution in pharyngo-laryngeal squamous cell carcinoma: comparison between pre- and per-treatment studies.

Authors:  Xavier Geets; Jean-Francois Daisne; Milan Tomsej; Thierry Duprez; Max Lonneux; Vincent Grégoire
Journal:  Radiother Oncol       Date:  2006-02-24       Impact factor: 6.280

3.  elastix: a toolbox for intensity-based medical image registration.

Authors:  Stefan Klein; Marius Staring; Keelin Murphy; Max A Viergever; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

4.  Evaluation of segmentation methods on head and neck CT: Auto-segmentation challenge 2015.

Authors:  Patrik F Raudaschl; Paolo Zaffino; Gregory C Sharp; Maria Francesca Spadea; Antong Chen; Benoit M Dawant; Thomas Albrecht; Tobias Gass; Christoph Langguth; Marcel Lüthi; Florian Jung; Oliver Knapp; Stefan Wesarg; Richard Mannion-Haworth; Mike Bowes; Annaliese Ashman; Gwenael Guillard; Alan Brett; Graham Vincent; Mauricio Orbes-Arteaga; David Cárdenas-Peña; German Castellanos-Dominguez; Nava Aghdasi; Yangming Li; Angelique Berens; Kris Moe; Blake Hannaford; Rainer Schubert; Karl D Fritscher
Journal:  Med Phys       Date:  2017-04-21       Impact factor: 4.071

5.  Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132.

Authors:  Kristy K Brock; Sasa Mutic; Todd R McNutt; Hua Li; Marc L Kessler
Journal:  Med Phys       Date:  2017-05-23       Impact factor: 4.071

6.  Fully automatic multi-organ segmentation for head and neck cancer radiotherapy using shape representation model constrained fully convolutional neural networks.

Authors:  Nuo Tong; Shuiping Gou; Shuyuan Yang; Dan Ruan; Ke Sheng
Journal:  Med Phys       Date:  2018-09-19       Impact factor: 4.071

7.  The Cancer Imaging Archive (TCIA): maintaining and operating a public information repository.

Authors:  Kenneth Clark; Bruce Vendt; Kirk Smith; John Freymann; Justin Kirby; Paul Koppel; Stephen Moore; Stanley Phillips; David Maffitt; Michael Pringle; Lawrence Tarbox; Fred Prior
Journal:  J Digit Imaging       Date:  2013-12       Impact factor: 4.056

8.  Shape constrained fully convolutional DenseNet with adversarial training for multiorgan segmentation on head and neck CT and low-field MR images.

Authors:  Nuo Tong; Shuiping Gou; Shuyuan Yang; Minsong Cao; Ke Sheng
Journal:  Med Phys       Date:  2019-05-06       Impact factor: 4.071

9.  Adaptive biological image-guided IMRT with anatomic and functional imaging in pharyngo-laryngeal tumors: impact on target volume delineation and dose distribution using helical tomotherapy.

Authors:  Xavier Geets; Milan Tomsej; John A Lee; Thierry Duprez; Emmanuel Coche; Guy Cosnard; Max Lonneux; Vincent Grégoire
Journal:  Radiother Oncol       Date:  2007-06-11       Impact factor: 6.280

10.  Fast parallel image registration on CPU and GPU for diagnostic classification of Alzheimer's disease.

Authors:  Denis P Shamonin; Esther E Bron; Boudewijn P F Lelieveldt; Marion Smits; Stefan Klein; Marius Staring
Journal:  Front Neuroinform       Date:  2014-01-16       Impact factor: 4.081

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.