Literature DB >> 15979375

Medical image registration with partial data.

Senthil Periaswamy1, Hany Farid.   

Abstract

We have developed a general-purpose registration algorithm for medical images and volumes. The transformation between images is modeled as locally affine but globally smooth, and explicitly accounts for local and global variations in image intensities. An explicit model of missing data is also incorporated, allowing us to simultaneously segment and register images with partial or missing data. The algorithm is built upon a differential multiscale framework and incorporates the expectation maximization algorithm. We show that this approach is highly effective in registering a range of synthetic and clinical medical images.

Mesh:

Year:  2005        PMID: 15979375     DOI: 10.1016/j.media.2005.03.006

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  27 in total

1.  Non-rigid registration with missing correspondences in preoperative and postresection brain images.

Authors:  Nicha Chitphakdithai; James S Duncan
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

2.  SEGMENTATION OF SERIAL MRI OF TBI PATIENTS USING PERSONALIZED ATLAS CONSTRUCTION AND TOPOLOGICAL CHANGE ESTIMATION.

Authors:  Bo Wang; Marcel Prastawa; Suyash P Awate; Andrei Irimia; Micah C Chambers; Paul M Vespa; John D van Horn; Guido Gerig
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2012

3.  ORBIT: a multiresolution framework for deformable registration of brain tumor images.

Authors:  Evangelia I Zacharaki; Dinggang Shen; Seung-Koo Lee; Christos Davatzikos
Journal:  IEEE Trans Med Imaging       Date:  2008-08       Impact factor: 10.048

4.  Automatic registration using implicit shape representations: applications in intraoperative 3D rotational angiography to preoperative CTA registration.

Authors:  Navneeth Subramanian; Eric Pichon; Stephen B Solomon
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-11-15       Impact factor: 2.924

5.  A non-rigid registration framework that accommodates resection and retraction.

Authors:  Petter Risholm; Eigil Samsett; Ion-Florin Talos; William Wells
Journal:  Inf Process Med Imaging       Date:  2009

6.  PAIRWISE REGISTRATION OF IMAGES WITH MISSING CORRESPONDENCES DUE TO RESECTION.

Authors:  Nicha Chitphakdithai; James S Duncan
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2010-04-14

7.  Extra-dimensional Demons: a method for incorporating missing tissue in deformable image registration.

Authors:  Sajendra Nithiananthan; Sebastian Schafer; Daniel J Mirota; J Webster Stayman; Wojciech Zbijewski; Douglas D Reh; Gary L Gallia; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

8.  A survey of GPU-based medical image computing techniques.

Authors:  Lin Shi; Wen Liu; Heye Zhang; Yongming Xie; Defeng Wang
Journal:  Quant Imaging Med Surg       Date:  2012-09

9.  A nonrigid registration method for correcting brain deformation induced by tumor resection.

Authors:  Yixun Liu; Chengjun Yao; Fotis Drakopoulos; Jinsong Wu; Liangfu Zhou; Nikos Chrisochoides
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

10.  A Patient-Specific Segmentation Framework for Longitudinal MR Images of Traumatic Brain Injury.

Authors:  Bo Wang; Marcel Prastawa; Andrei Irimia; Micah C Chambers; Paul M Vespa; John D Van Horn; Guido Gerig
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.