Literature DB >> 3405133

The three parameter equivalent spectra as an index of beam quality.

J M Boone1.   

Abstract

A parametric spectral model based on the work of Birch and Marshall is used to characterize the x-ray spectra of a specific x-ray system. Using least-squares comparison between measured and calculated attenuation data, an equivalent spectrum (EQSPEC) is iteratively found which very closely matches the measured attenuation characteristics of the x-ray system. The resulting parametric spectrum is a function of the anode angle (theta), equivalent kilovoltage (kVeq), and the equivalent aluminum filtration (Aleq), and these three parameters can serve as very concise yet very accurate indices of beam quality. The utility of the EQSPEC for characterization and reporting of x-ray spectra (and thus beam quality) may have numerous applications in diagnostic imaging procedures where spectral quality is an important consideration.

Entities:  

Mesh:

Year:  1988        PMID: 3405133     DOI: 10.1118/1.596223

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Conversion coefficients for determining organ doses in paediatric spine radiography.

Authors:  Michael Seidenbusch; Karl Schneider
Journal:  Pediatr Radiol       Date:  2014-02-09

2.  Experimental verification of reverse order of diagnostic X-ray beam quality in voltage-ripple dependence.

Authors:  M Matsumoto; H Kubota; Y Ozaki; H Kanamori
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

Review 3.  [Aspects of radiation protection during chest X-radiography].

Authors:  M C Seidenbusch; K Schneider
Journal:  Radiologe       Date:  2015-07       Impact factor: 0.635

4.  Computer simulations and models for the performance characteristics of spectrally equivalent X-ray beams in medical diagnostic radiology.

Authors:  Akintunde A Okunade
Journal:  J Med Phys       Date:  2007-10

5.  Conversion coefficients for determining organ doses in paediatric pelvis and hip joint radiography.

Authors:  Michael C Seidenbusch; Karl Schneider
Journal:  Pediatr Radiol       Date:  2014-05-08

6.  Experimental implementation of a polyenergetic statistical reconstruction algorithm for a commercial fan-beam CT scanner.

Authors:  Joshua D Evans; Bruce R Whiting; David G Politte; Joseph A O'Sullivan; Paul F Klahr; Jeffrey F Williamson
Journal:  Phys Med       Date:  2013-01-21       Impact factor: 2.685

  6 in total