BACKGROUND: Knowledge of organ and effective doses achieved during paediatric X-ray examinations is an important prerequisite for assessment of radiation burden to the patient.
OBJECTIVE: Conversion coefficients for reconstruction of organ and effective doses from entrance doses for pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission.
MATERIALS AND METHODS: Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Säteilyturvakeskus STUK), conversion coefficients for conventional pelvis and hip joint radiographs were calculated by performing Monte Carlo simulations in mathematical hermaphrodite phantom models representing patients of different ages. The clinical variation of radiation field settings was taken into consideration by defining optimal and suboptimal standard field settings.
RESULTS: Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal beam projection and the standard focus detector distance of 115 cm.
CONCLUSION: The conversion coefficients presented can be used for organ dose assessments from entrance doses measured during pelvis and hip joint radiographs of children and young adults with all field settings within the optimal and suboptimal standard field settings.

Entities:  

Mesh:

Year:  2014        PMID: 24805203     DOI: 10.1007/s00247-014-2962-8

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  16 in total

1.  The three parameter equivalent spectra as an index of beam quality.

Authors:  J M Boone
Journal:  Med Phys       Date:  1988 May-Jun       Impact factor: 4.071

2.  Patient exposure in medical X-ray imaging in Europe.

Authors:  Dieter F Regulla; Heinrich Eder
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

3.  Breast cancer mortality after diagnostic radiography: findings from the U.S. Scoliosis Cohort Study.

Authors:  M M Doody; J E Lonstein; M Stovall; D G Hacker; N Luckyanov; C E Land
Journal:  Spine (Phila Pa 1976)       Date:  2000-08-15       Impact factor: 3.468

4.  The Reference Man in diagnostic radiology dosimetry.

Authors:  B A Lindskoug
Journal:  Br J Radiol       Date:  1992-05       Impact factor: 3.039

5.  [Radiation exposure of children in pediatric radiology. Part 3: Conversion coefficients for reconstruction of organ doses achieved during chest X-ray examinations].

Authors:  M C Seidenbusch; D Regulla; K Schneider
Journal:  Rofo       Date:  2008-11-28

6.  Projecting the lifetime risk of cancer from exposure to diagnostic ionizing radiation for adolescent idiopathic scoliosis.

Authors:  A R Levy; M S Goldberg; J A Hanley; N E Mayo; B Poitras
Journal:  Health Phys       Date:  1994-06       Impact factor: 1.316

7.  [Radiation exposure of children in pediatric radiology. Part 6: conversion factors for reconstruction of organ dose in abdominal radiography].

Authors:  M C Seidenbusch; D Regulla; K Schneider
Journal:  Rofo       Date:  2009-06-10

8.  [Radiation exposure of children in pediatric radiology--part 2: the PAEDOS algorithm for computer-assisted dose reconstruction in pediatric radiology and results for X-ray examinations of the skull].

Authors:  M C Seidenbusch; D Regulla; K Schneider
Journal:  Rofo       Date:  2008-05-16

9.  Breast cancer in women with scoliosis exposed to multiple diagnostic x rays.

Authors:  D A Hoffman; J E Lonstein; M M Morin; W Visscher; B S Harris; J D Boice
Journal:  J Natl Cancer Inst       Date:  1989-09-06       Impact factor: 13.506

10.  The construction of computer tomographic phantoms and their application in radiology and radiation protection.

Authors:  M Zankl; R Veit; G Williams; K Schneider; H Fendel; N Petoussi; G Drexler
Journal:  Radiat Environ Biophys       Date:  1988       Impact factor: 1.925

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.